Peter Huber Kältemaschinenbau Unichiller P022-H OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P022-H OLÉ

Peter Huber Kältemaschinenbau Unichiller P022-H OLÉ — Recirculating chillers with Noise level 65 dB.

The Unichiller P022-H OLÉ is a recirculating chiller with a 'P' designation for high-pressure-drop circuits, rated -10 to 100 °C with 2.2 kW cooling at 15 °C falling to 1 kW at -10 °C. Its OLÉ controller, 25 l/min pump and G3/4 male connections suit closed-loop process cooling where the external circuit imposes significant pressure loss.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P022-H OLÉ Current 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A) (sound pressure level)
Maximum delivery flow rate 25 l/min (max pump delivery capacity)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -10...100 °C
Dimensions, Weight & Mechanical Design
Weight 83 kg
Electrical, Power & Drive Specifications
Current consumption 15 A (max)
Fuse rating 16 A
Power supply 208-230V 1~/2~ 60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible ambient temperature)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The P022-H OLÉ is an air-cooled recirculating chiller in the Unichiller series, distinguished from the 015 siblings by the 'P' model designation, which the manual states makes it particularly suitable for applications requiring high pressure drops. It is intended only for externally closed circuits. The pump delivers up to 25 l/min and 2.5 bar, with the published curve giving 21 l/min at 0.5 bar down to 6 l/min at 2.0 bar, so the external loop's pressure loss must be checked against this curve rather than the free-delivery figure. The pump is type B, non-adjustable in speed, with G3/4 AG male connections.

Thermal behavior

Control, installation and operation

The OLÉ controller provides an OLED display with 0.1 K resolution, USB (Device) and RS232 interfaces. Power-failure response is configurable (OFF/Standby, ON, Power Failure Auto). The unit is IP20, Class A Group 1 per EN55011, and must be installed indoors at ≥300 lx and up to 2000 m altitude, outside any ATEX zone. Free-standing installation requires 50 to 200 cm wall clearance per side for maintenance. Leveling feet or caster brakes must be set before start-up. Refrigerant is R-449A, 0.56 kg, GWP 1397 (0.8 t CO2e); charge versus room volume must be checked at installation.

Integration & Operating Notes

Electrical
Supply tolerances must be met simultaneously, not independently

The 208-230 V 1~/2~ 60 Hz feed must satisfy ±5% voltage and ±2% frequency together; the datasheet explicitly disallows a -5% voltage with +2% frequency combination. Max current is 15 A with a 16 A fuse, so breaker and cable sizing must cover the 15 A figure, and the country-specific plug must be specified at ordering.

Unichiller P022-H OLÉ Datasheet, page 2
Process Limits
Pump curve, not free delivery, governs high-pressure-drop loops

The 'P' designation targets high-pressure-drop applications, but the pump still falls from 21 l/min at 0.5 bar to 6 l/min at 2.0 bar against a 2.5 bar maximum. Calculate the external circuit's pressure loss at the required flow before committing; a loop that demands more than the curve allows at the set point will under-deliver coolant and distort the process temperature.

Unichiller P022-H OLÉ Datasheet, page 1
Cooling & Media
Plastic pump excludes acetone and polyglycols from the loop

The pump is not resistant to acetone or polyglycols (manufacturer-dependent), so these fluids must be avoided or a more resistant pump specified. For sub-zero set points, mix water with glysantine or ethylene glycol for freeze protection rather than running pure water. Minimum system filling capacity is 3.8 l with a 1.7 l expansion vessel.

Unichiller P022-H OLÉ Datasheet, page 2
Mounting
Indoor, non-ATEX site with 50-200 cm side clearance required

The unit is not explosion-protected and must not be installed or started in an ATEX zone. It is for indoor use only, at ≥300 lx illuminance and up to 2000 m altitude, with 50 to 200 cm wall clearance per side for maintenance. IP20 means a dry, protected location; electrical lines directly below a water-cooled unit must be shielded from condensate.

Unichiller Operation Manual, pages 13, 25, 28
Maintenance
Refrigerant circuit work restricted to approved contractors

Any work on the coolant/refrigerant circuit must be carried out by approved refrigeration and air-conditioning system contractors; the R-449A charge of 0.56 kg (GWP 1397, 0.8 t CO2e) also triggers room-volume checks at installation. Shut off cooling water supply even for overnight downtimes, and set leveling feet or caster parking brakes before start-up to prevent movement.

Unichiller Operation Manual, pages 15, 17, 28, 31

Selection & Integration Q&A

When should I choose the P022-H OLÉ over the Unichiller 015 variants?

Pick the P022-H when the external circuit has high pressure drop (the 'P' designation) and the load needs up to 2.2 kW at 15 °C down to 1 kW at -10 °C. The 015 siblings are lower-capacity; choose them only if the loop's pressure loss and heat load fit their smaller envelope.

What must I verify about the external loop and power feed before ordering?

Check the loop's pressure loss against the pump curve (21 l/min at 0.5 bar to 6 l/min at 2.0 bar, 2.5 bar max) and provide at least 3.8 l system fill with a 1.7 l expansion vessel. The feed must be 208-230 V 1~/2~ 60 Hz, 15 A max, 16 A fuse, with ±5% V and ±2% f met simultaneously.

Where can the unit be installed and how much space does it need?

Indoors only, outside any ATEX zone, at ≥300 lx and up to 2000 m altitude, with ambient 5-40 °C. Allow 50-200 cm wall clearance per side for maintenance, keep it dry (IP20), and set leveling feet or caster brakes before start-up.

What maintenance and delivery items should I plan for beyond the base unit?

Refrigerant circuit work requires approved refrigeration contractors; the R-449A charge (0.56 kg, 0.8 t CO2e) needs a room-volume check. The power cable and country-specific plug must be specified at ordering. For sub-zero duty, plan glysantine or ethylene glycol freeze protection; acetone and polyglycols are excluded by the plastic pump.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P022-H OLÉ Datasheet
Datasheet ·96,0 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF