Peter Huber Kältemaschinenbau Unichiller P015-H
Peter Huber Kältemaschinenbau Unichiller P015-H — Recirculating chillers with Noise level 63 dB.
The Unichiller P015-H is a recirculating chiller with a 'P' designation for high-pressure-drop applications, rated -20 to 100 °C and cooled by flammable R-290 refrigerant. It delivers 1.5 kW at 15 °C falling to 0.3 kW at -20 °C, and its 25 l/min, 2.5 bar pump serves externally closed loops.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P015-H Current | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Noise level | 63 dB(A) |
| Maximum delivery flow rate | 25 l/min (pressure pump max; also 2, 5 bar) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 62 kg |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The P015-H is the high-pressure-drop variant of the Unichiller 015 platform; the 'P' in the model name marks it as particularly suitable for applications requiring high pressure drops, per the operation manual.
- It shares the 63 dB(A) noise level of the sibling Unichiller 015, 015-H and OLÉ variants, but differs by pump characteristic rather than by cooling capacity class.
- The refrigerant is R-290 (A3, H220), a flammable natural refrigerant, so installation must respect refrigerant charge per room volume and ignition-source control.
- Hydraulic connection is a single G3/4 male pump port; the pump is type B, non-adjustable in speed.
Behavior under load and media
- Cooling capacity is strongly temperature-dependent: 1.5 kW at 15 °C, 1 kW at 0 °C, 0.7 kW at -10 °C and 0.3 kW at -20 °C, all valid at 20 °C room temperature; capacity may drop as ambient rises toward the 40 °C limit.
- The pump delivers up to 25 l/min at 2.5 bar maximum pressure, with flow falling as pressure rises, which is why the high-pressure-drop 'P' variant exists.
- The unit is designed for externally closed applications only; minimum filling capacity is 3.8 l with 1.7 l expansion volume.
- Overtemperature protection is adjustable per DIN 12876; in Process Safety mode the controller releases maximum cooling capacity when the OT trigger is reached instead of switching off all poles.
Installation, control and operation
- The Pilot ONE controller provides Ethernet, USB host/device and RS232 interfaces, plus a Pt100 external sensor connection.
- Power-failure response is configurable as OFF/Standby, ON or Power Failure Auto via the Pilot ONE.
- Electrical supply is 220-240 V 1~ 50 Hz, max current 15.5 A, 16 A fuse; voltage tolerance ±5% is permitted only with simultaneous ±2% frequency tolerance, and some combinations are not allowed.
- The unit is IP20, EN55011 Class A Group 1, and must be installed indoors at 5-40 °C ambient with at least 300 lx illuminance and up to 2000 m altitude.
Integration & Operating Notes
The manual restricts this chiller to externally closed applications, so the hydraulic circuit must be a sealed loop with an expansion volume of 1.7 l and a minimum fluid charge of 3.8 l; open tanks or atmospheric vessels are outside the intended use.
Cooling capacity falls from 1.5 kW at 15 °C to 0.3 kW at -20 °C, so processes with sustained cold loads near the lower end of the -20...100 °C range must be sized against the actual setpoint capacity, not the 15 °C figure.
A ±5% voltage deviation is allowed only with a simultaneous ±2% frequency tolerance, and some combinations are not allowed; verify the site supply against both before connection, since the unit draws up to 15.5 A on a 16 A fuse.
Single-phase devices are supplied with a power cable and a country-specific plug that must be specified at ordering; confirm the plug type for the installation country so commissioning is not delayed by a missing or wrong connector.
The refrigerant is R-290 (A3, H220), a flammable natural refrigerant; the charge stated on the rating plate and the room size must be checked at installation so the refrigerant limit per m³ of ambient air is not exceeded, and ignition sources must be controlled.
Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access; the unit must also be installed indoors at 5-40 °C ambient, at least 300 lx illuminance and no higher than 2000 m altitude.
The unit is not explosion-protected and must not be installed or started up within an ATEX zone; this constrains siting whenever the chiller serves a process area classified for flammable atmospheres.
The pump connection is G3/4 male; hoses and fittings must match this thread, connections must be counterheld during tightening, and the maximum torques in the manual table must not be exceeded to avoid damage and leaks.
The Pilot ONE can be configured for OFF/Standby, ON or Power Failure Auto after a mains failure; the selected behavior determines whether the process restarts automatically, so it must be set deliberately for each application.
In Process Safety mode the controller releases maximum cooling capacity when the adjustable overtemperature trigger per DIN 12876 is reached, rather than switching off all poles; select this mode only where full cooling at the OT limit is safe for the process.
Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; plan service access and contracts accordingly, since the R-290 circuit cannot be serviced by general maintenance staff.
The cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion; electrical lines directly below a water-cooled unit must also be protected against liquid ingress from condensation.
Selection & Integration Q&A
Pick the P015-H when the process loop has a high pressure drop: the 'P' model is specifically suited to such applications, and its pump reaches 2.5 bar at up to 25 l/min. The plain 015 and 015-H share the same 63 dB(A) class but not this high-pressure-drop pump characteristic.
The loop must be externally closed with at least 3.8 l fill and 1.7 l expansion volume, mated to the G3/4 male pump port with counterheld fittings. Supply must be 220-240 V 1~ 50 Hz, 16 A fuse, with ±5% voltage only alongside ±2% frequency tolerance.
Indoors only, 5-40 °C ambient, at least 300 lx, up to 2000 m altitude, with 50-200 cm wall clearance per side and no ATEX zone. Before switching on, activate parking brakes and/or unscrew the leveling feet so the unit cannot move.
Refrigerant circuit work needs approved refrigeration contractors, and the country-specific plug must be specified at ordering since the cable is supplied with it. Cooling water must be shut off for even overnight stops; plan service access of 50-200 cm per side.