Peter Huber Kältemaschinenbau Unichiller P022 OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P022 OLÉ

Peter Huber Kältemaschinenbau Unichiller P022 OLÉ — Recirculating chillers with Noise level 65 dB.

The Unichiller P022 OLÉ is a recirculating chiller with a 'P' designation for high-pressure-drop loops, rated -10 to 40 °C and 2.2 kW at 15 °C. Its OLÉ controller and 21 l/min pump at 0.5 bar distinguish it from 015 siblings. It serves externally closed cooling circuits in dry indoor sites.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P022 OLÉ Current 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 81 kg
Electrical, Power & Drive Specifications
Current consumption 9 A
Power supply 220-240V 1~ 50Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Loop pressure drop must match the pump curve

The pump delivers 21 l/min at 0.5 bar but only 6 l/min at 2.0 bar. A high-pressure-drop loop will see strongly reduced flow, so calculate the circuit pressure drop and verify the resulting flow against the curve before commissioning.

Technical Datasheet, p. 1
Cooling & Media
Avoid acetone and polyglycols with the plastic pump

The standard plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). Using these fluids risks pump failure; specify an alternative pump or choose a different heat transfer fluid.

Technical Datasheet, p. 2
Electrical
Supply tolerance is ±5% voltage only with ±2% frequency

The datasheet permits ±5% voltage tolerance only with a simultaneous ±2% frequency tolerance, and certain combinations are not allowed. Verify the site supply quality before connection; a generator or weak grid may exceed these limits.

Technical Datasheet, p. 2
Electrical
Country-specific plug must be specified at ordering

Single-phase devices are supplied with a power cable and country-specific plug that must be stated when ordering. Confirm the plug type for the installation country to avoid a missing or wrong connector on delivery.

Technical Datasheet, p. 2
Mounting
Keep 50 to 200 cm clearance per side for maintenance

Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. Plan the installation footprint accordingly; a tight enclosure will block service access to the refrigerant circuit and pump.

Operation Manual, p. 25
Mounting
Not permitted inside an ATEX zone

The unit is not explosion-protected and must not be installed or started up within an ATEX zone. Additionally, the R-290 refrigerant charge and room volume must be checked to avoid exceeding the refrigerant limit per m³ of ambient air.

Operation Manual, p. 13 and p. 15
Mounting
Indoor site with at least 300 lx illuminance

The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude. Ambient temperature must stay within 5 to 40 °C; capacity data are valid at 20 °C room temperature and may drop if the room is warmer.

Operation Manual, p. 25; Technical Datasheet, p. 2
Control & I/O
Configure power-failure response for the process risk

The power-failure response can be set to OFF/Standby, ON or Power Failure Auto via the Pilot ONE. For exothermic processes, choose the mode that restarts cooling automatically; for safe processes, OFF/Standby prevents unexpected restart.

Operation Manual, p. 19
Control & I/O
Process Safety mode releases maximum cooling on OT trigger

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is relevant for exothermic reactions where cutting cooling would cause runaway temperatures.

Operation Manual, p. 18
Maintenance
Refrigerant circuit work only by approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The R-290 (A3, H220) flammable refrigerant charge also requires checking the room volume at installation.

Operation Manual, p. 17
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply must be shut off even for shorter downtimes such as overnight to prevent water damage and corrosion. Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation.

Operation Manual, p. 28

Selection & Integration Q&A

When should I choose the P022 OLÉ instead of a Unichiller 015 sibling?

Choose the P022 OLÉ for high-pressure-drop loops (the 'P' designation) and when the 2.2 kW at 15 °C capacity is needed. The 015 siblings are lower-capacity neighbors at 63 dB(A); the P022 OLÉ is rated 65 dB(A). Select the 015 when its capacity covers the load and high pressure drop is not a constraint.

What hydraulic and electrical requirements must adjacent system parts meet?

The pump connection is G3/4 male, so mating hoses and couplings must match this thread and be counterheld at the maximum tightening torque. The supply is 220-240 V single-phase 50 Hz with a minimum 10 A fuse; voltage tolerance is ±5% only with ±2% frequency tolerance. The loop must be externally closed and its pressure drop matched to the pump curve.

What mounting and duty-cycle limits apply from the manual?

Install indoors only, at 5 to 40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude, with 50 to 200 cm clearance per side for maintenance. The unit is IP20 and not permitted in an ATEX zone. Activate leveling feet and parking brakes before operation; check the R-290 charge against room volume.

What maintenance and consumables are required, and what is not included in base delivery?

Refrigerant circuit work must be done by approved refrigeration/air-conditioning contractors. The heat transfer fluid must be prepared with glysantine or ethylene glycol for freeze protection; acetone and polyglycols must be avoided with the plastic pump. The power cable and country-specific plug must be specified at ordering; the manual does not list a spare-parts kit in base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P022 OLÉ — Technical Datasheet
Datasheet ·130,0 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF