Peter Huber Kältemaschinenbau Unichiller P015w
Peter Huber Kältemaschinenbau Unichiller P015w — Recirculating chillers with Noise level 54 dB.
Water-cooled recirculating chiller with a plastic pump and fixed-speed drive, rated for -20 to 40 °C and built for externally closed circuits with high pressure drop. The 'P' modification trades flow for head (25 l/min max, 6 l/min at 2.0 bar) and runs quieter than the 015 siblings at 54 dB(A). It serves as the cooling stage for closed process loops.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P015w Current | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Noise level | 54 dB(A) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 220-240V 1~/2~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 36 l/h (cooling water at 15°C, flow -20°C) cooling water at 15°C, flow -10°C: 48 l/h · cooling water at 15°C, flow 0°C: 60 l/h · cooling water at 15°C, flow 15°C: 68 l/h |
| Cooling water differential pressure | 1 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and positioning
- Water-cooled refrigeration circuit using R-449A (GWP 1397), CFC- and HCFC-free; cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.
- Plastic pump, type B, fixed speed (not adjustable), G3/4 AG male pump connection; cooling water connections G1/2 male.
- Within the Unichiller 015 family, the P015w is the high-pressure-drop variant: the 'P' designation marks units suited to applications requiring high pressure drops, and it is quieter (54 dB(A)) than the 015, 015-H, 015 OLÉ and 015-H OLÉ siblings (63 dB(A)).
- Intended only for externally closed applications; not explosion-protected and must not be installed in an ATEX zone.
Behavior under load and media
- Temperature range -20 to 40 °C; ambient 5 to 40 °C; IP20.
- Pump curve: 25 l/min maximum delivery, 2.5 bar maximum delivery pressure, but only 6 l/min at 2.0 bar — high-impedance loops must be checked against this curve.
- Cooling water consumption depends on the operating point at 15 °C cooling water: 36 l/h at -20 °C, 48 l/h at -10 °C, 60 l/h at 0 °C, 68 l/h at 15 °C. Cooling power drops and required flow may rise as cooling water temperature increases, so size the supply for actual site conditions.
- Cooling water intake designed for 5 to 20 °C; if below the condensation point, insulate the cooling water pipes in the unit.
- Plastic pump is not resistant to acetone or polyglycols; for freeze protection use water mixed with glysantine or ethylene glycol. Minimum filling capacity 3.8 l; expansion vessel 1.7 l.
Installation, control and operation
- Pilot ONE controller with Ethernet, USB (host and device) and RS232; external Pt100 sensor connection.
- Power supply 220-240 V 1~/2~ 50 Hz, max current 5.5 A, fuse 10-16 A; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and -5% voltage with +2% frequency is not allowed.
- Single/two-phase units ship with power cable and country-specific plug (must be specified at order); three-phase units below 63 A ship with cable but no plug.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto; Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off.
- Leveling feet must be extended and caster parking brakes applied before startup; wall clearance 50-200 cm per side for maintenance; indoor use only, illuminance at least 300 lx, altitude up to 2000 m.
Integration & Operating Notes
The chiller needs a minimum cooling water differential pressure of 1 bar and tolerates no more than 6 bar. Insufficient pressure prevents proper operation; excessive pressure can damage the water circuit, so a regulator or pressure-reducing valve may be needed upstream.
The unit is designed for cooling water intake between 5 and 20 °C. When the cooling water temperature falls below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensation and possible damage.
The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). For freeze protection, use a water mixture with glysantine or ethylene glycol instead, and confirm fluid compatibility with the mixed-material water circuit (copper, 1.4401, MS, PA, PPE, PTFE, EPDM).
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and the combination of -5% voltage with +2% frequency is explicitly not allowed. Check the site supply against this combined envelope before commissioning; the unit draws up to 5.5 A and requires a 10-16 A fuse.
Single/two-phase devices (100-240 V) are delivered with a power cable and country-specific plug that must be specified when ordering. Three-phase devices below 63 A come with cable but without plug, so the site must provide a matching receptacle or plug.
Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. The unit is for indoor use only at illuminance of at least 300 lx and up to 2000 m altitude, and must not be installed or started inside an ATEX zone.
Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. Also observe the refrigerant charge and room size at installation to stay within the refrigerant limit per m³ of ambient air.
Close the cooling water supply to the unit even for shorter downtimes such as overnight to prevent water damage and corrosion. Before switching on, extend the leveling feet and apply caster parking brakes so the unit cannot move during operation.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto. Choose according to whether the process must restart automatically after a power outage or remain stopped for manual intervention.
In Process Safety mode the controller releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.
Work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-449A with GWP 1397, which also carries regulatory and environmental reporting obligations at the site.
Selection & Integration Q&A
Choose the P015w for closed loops with high pressure drop: the 'P' model is specifically suited to such applications and runs at 54 dB(A) versus 63 dB(A) for the 015, 015-H and OLÉ siblings. The 015 variants suit lower-impedance circuits where their higher flow is usable.
Provide cooling water at 5-20 °C intake with differential pressure between 1 and 6 bar, connections G1/2 male. Flow demand at 15 °C water is 36-68 l/h depending on setpoint (-20 to 15 °C). Insulate internal cooling water pipes if intake falls below the condensation point.
Indoor use only, ambient 5-40 °C, illuminance at least 300 lx, altitude up to 2000 m, IP20, no ATEX zone. Keep 50-200 cm clearance per side, protect cables below the unit from condensation, and shut off cooling water even for overnight downtime.
Three-phase units below 63 A ship without a plug; single/two-phase units need the country-specific plug specified at order. Refrigerant circuit service requires approved contractors. Plan a 10-16 A fuse, external Pt100 sensor if needed, and freeze-protection fluid (glysantine or ethylene glycol mix).