Peter Huber Kältemaschinenbau Unichiller 015
Peter Huber Kältemaschinenbau Unichiller 015 — Recirculating chillers with Noise level 63 dB.
The Unichiller 015 is a compact air-cooled recirculating chiller with an immersion pump and Pilot ONE controller, rated 1 kW at 0 °C over a -20…40 °C range. It is the base model of the Unichiller 015 series, distinguished from the -H, OLÉ and w siblings by its standard configuration and 63 dB(A) noise level. It serves externally closed industrial process cooling loops.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 015 Current | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Noise level | 63 dB(A) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | Yes |
| Pump type | Immersion pump |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 56 kg |
| Current consumption | 8 A (max.) |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 1 kW (at 0 °C) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The Unichiller 015 is an air-cooled, single-stage recirculating chiller using R-290 (A3, H220) refrigerant with a charge of 0.16 kg. It is built for externally closed applications only. Within the Unichiller 015 family, this base model shares the 63 dB(A) noise level with the -H, -H OLÉ and OLÉ variants, while the 015w sibling is quieter at 54 dB(A). The unit uses a plastic immersion pump with adjustable speed and G3/4 AG male connections; this pump is not resistant to acetone or polyglycols. Cooling is via an air-cooled condenser, so capacity depends on ambient temperature and airflow.
Thermal and hydraulic behavior
Cooling capacity is strongly temperature-dependent: 1.5 kW at +15 °C, 1 kW at 0 °C and 0.3 kW at -20 °C. The process load must therefore be checked at the actual working temperature, not at nominal capacity. The immersion pump delivers a maximum of 29 l/min at 1 bar and 21 l/min at 0.5 bar, so the pressure drop of the external circuit must be compared against this curve. The temperature range is -20…40 °C. For sub-zero operation, water should be mixed with glysantine or ethylene glycol for freeze protection. Minimum filling capacity is 3.8 l with 1.7 l expansion volume; the external loop volume must be included when charging.
Electrical, control and installation
Electrical supply is 220-240 V single-phase 50 Hz with 8 A maximum current and a 16 A fuse. Voltage and frequency tolerances are ±5 % and ±2 % but must not be combined in opposite directions. The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, a Pt100 external sensor connection, and configurable power-failure response (OFF/Standby, ON, or Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles. The unit is IP20 and must be installed indoors at 5…40 °C ambient with at least 300 lx illuminance and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance. It must not be installed in an ATEX zone. Leveling feet must be activated and parking brakes applied before startup. Electrical lines directly below the unit must be protected against liquid ingress. EMC classification is Class A, Group 1, intended for industrial environments.
Integration & Operating Notes
Capacity falls from 1.5 kW at +15 °C to 0.3 kW at -20 °C, so sizing on the 1 kW at 0 °C figure will undersize the unit for low-temperature duty. Verify the process heat load at the lowest intended set point before selection.
The standard immersion pump is not resistant to acetone or polyglycols. These media require a more resistant pump option or must be avoided entirely to prevent chemical attack and pump failure.
For operation below 0 °C, water should be mixed with glysantine or ethylene glycol rather than used pure, to avoid freezing and damage in the cooling circuit. Minimum filling capacity is 3.8 l with 1.7 l expansion volume.
Voltage tolerance is ±5 % and frequency tolerance ±2 %, but a -5 % voltage combined with +2 % frequency is not allowed. Verify supply quality at the installation site before commissioning to stay within the permitted envelope.
The chiller is not explosion-protected and uses R-290 (A3 flammable) refrigerant. The installation location must be assessed for flammable-refrigerant safety and ventilation, and refrigerant charge versus room size must be checked against the limit per m³ of ambient air.
Free-standing models need this clearance on either side for maintenance access. Insufficient clearance also degrades air-cooled condenser performance and may cause overtemperature trips. The unit must be used indoors at 5…40 °C ambient with at least 300 lx illuminance.
Parking brakes must be activated at the casters (if any) and/or leveling feet unscrewed/activated before the unit is put into operation, to prevent movement and crushing injuries during operation.
The Pilot ONE allows OFF/Standby, ON, or Power Failure Auto. The choice determines whether the process restarts automatically after a power outage, which is critical for unattended or exothermic processes.
In Process Safety mode, maximum cooling capacity is released when the overtemperature trigger value is detected, instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant charge is 0.16 kg with GWP 0.02, so leak-check and record-keeping obligations are minimal but still apply.
Selection & Integration Q&A
Choose the base 015 for standard externally closed cooling where 63 dB(A) is acceptable. The 015w is quieter at 54 dB(A) for noise-sensitive sites. The -H and OLÉ variants share the 63 dB(A) level; select them only when their specific configuration is required, as they do not differ in noise from the base model.
A 220-240 V single-phase 50 Hz supply with 8 A maximum current and a 16 A fuse. Voltage tolerance is ±5 % and frequency ±2 %, but these must not be combined in opposite directions (e.g. -5 % voltage with +2 % frequency is not allowed). Verify supply quality before commissioning.
No. It must not be installed or started up inside an ATEX zone because it is not explosion-protected, and it uses R-290 (A3 flammable) refrigerant. It is for indoor use only at 5…40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, with 50 to 200 cm wall clearance per side.
Refrigerant circuit work must be performed only by approved refrigeration/air-conditioning contractors. The refrigerant charge is 0.16 kg (GWP 0.02). Heat transfer fluid is not included; minimum filling capacity is 3.8 l with 1.7 l expansion volume, and freeze protection (glysantine or ethylene glycol) must be added for sub-zero operation. Leveling feet and parking brakes must be set before startup.