Peter Huber Kältemaschinenbau Unichiller 022w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 022w

Peter Huber Kältemaschinenbau Unichiller 022w — Recirculating chillers with Noise level 60 dB.

The Unichiller 022w is a water-cooled recirculating chiller with a plastic immersion pump and Pilot ONE controller, covering -10 to 40 °C. It is the 022w modification of the Unichiller series, distinguished by its water-cooled condenser and G1/2 cooling-water connections. It serves externally closed process loops requiring stable temperature control with facility cooling water.

Noise level
60 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 022w Current 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 60 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable Yes
Pump type Immersion pump
External sensor connection Pt100
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 61 kg
Electrical, Power & Drive Specifications
Fuse rating 16 A
Power supply 220-240V 1~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 77 л/час (at 15°C, flow -10°C)
at 15°C, flow 0°C: 96 l/h · at 15°C, flow 15°C: 95 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The Unichiller 022w is a water-cooled recirculating chiller in the Unichiller series (up to 25 kW class). Unlike sibling models such as the Unichiller 015 variants, this model uses a water-cooled condenser with G1/2 male cooling-water connections, requiring a facility cooling-water supply rather than an air-cooled condenser. The unit is built for externally closed applications only, as stated in the manual. The pump is a plastic immersion pump with G3/4 AG male process connections and adjustable speed. The controller is the Pilot ONE, with Ethernet, USB (Host and Device) and RS232 interfaces. The unit is rated IP20 and safety class I / NFL, and is not explosion-protected (no ATEX zone installation).

Behavior under load and media

Cooling capacity depends on cooling-water temperature: as the cooling-water temperature rises, cooling power drops and the required cooling-water flow rate may increase. The datasheet specifies cooling-water inlet temperature between 5 °C and 20 °C. Cooling-water consumption is given as 77 l/h at 15 °C cooling water with -10 °C flow, 96 l/h at 15 °C with 0 °C flow, and 95 l/h at 15 °C with 15 °C flow. The cooling-water circuit must be supplied at a minimum differential pressure of 1 bar and must not exceed 6 bar. The process temperature range is -10 to 40 °C. The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol. The cooling-water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so the cooling water must be compatible with these materials.

Installation, control and operation

The unit must be installed indoors at an illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. Leveling feet must be activated and parking brakes applied before start-up. Electrical lines directly below the unit must be protected against liquid ingress. The cooling water supply must be shut off even for short downtimes such as overnight. If cooling water temperature can fall below the condensation point, the cooling water pipes inside the unit must be insulated. The power-failure response can be configured as OFF/Standby, ON, or Power Failure Auto via the Pilot ONE. Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached. The unit uses R-290 refrigerant (A3, H220) with GWP 0.02 and a charge of 0.17 kg; refrigerant circuit work must only be performed by approved refrigeration/air-conditioning contractors. The unit is classified to DIN 12876 with identification depending on whether the thermal fluid is combustible. It is EN55011 Class A, Group 1. Single-phase devices are supplied with a power cable and country-specific plug, which must be specified at ordering. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed.

Integration & Operating Notes

Process Limits
Cooling water must stay within 5–20 °C inlet temperature

The datasheet specifies a cooling-water inlet temperature range of 5 to 20 °C. Facility water outside this range will reduce cooling capacity or may prevent the unit from reaching the required process temperature. If the cooling water can fall below the condensation point, internal cooling-water pipes must be insulated to prevent condensation and electrical risk.

Unichiller 022w Datasheet, page 2
Process Limits
Cooling-water pressure must not exceed 6 bar

The cooling-water circuit is rated for a maximum pressure of 6 bar and requires a minimum differential pressure of 1 bar. Exceeding 6 bar risks damage to the internal cooling-water circuit. Ensure the facility supply is regulated or protected against pressure surges.

Unichiller 022w Datasheet, page 2
Cooling & Media
Plastic pump incompatible with acetone and polyglycols

The immersion pump is made of plastic and is not resistant to acetone or polyglycols (depending on the manufacturer). These fluids must not be used as the heat transfer medium. For freeze protection, water should be mixed with glysantine or ethylene glycol.

Unichiller 022w Datasheet, page 2
Mounting
Maintain 50–200 cm wall clearance per side for service

Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. The unit must be installed indoors at an illuminance of at least 300 lx and up to 2000 m altitude. Leveling feet must be activated and parking brakes applied before start-up.

Unichiller Operation Manual, page 25 and page 31
Electrical
Country-specific plug must be specified at ordering

Single-phase devices are supplied with a power cable and country-specific plug. The plug type must be specified when ordering to avoid delays or rework at installation. The unit is classified as EN55011 Class A, Group 1, which may require additional EMC measures in residential or sensitive environments.

Unichiller 022w Datasheet, page 2
Control & I/O
Configure power-failure response for safe process restart

The Pilot ONE controller allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For processes where automatic restart after power recovery is unsafe, select OFF/Standby. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles.

Unichiller Operation Manual, page 18 and page 19
Maintenance
Refrigerant circuit work only by approved contractors

The unit uses R-290 refrigerant (A3, H220) with a charge of 0.17 kg. Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. The unit is not explosion-protected and must not be installed or started up inside an ATEX zone.

Unichiller Operation Manual, page 17 and page 13
Operation
Shut off cooling water even for overnight downtime

The cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion during idle periods. Electrical lines directly below the unit must be protected against liquid ingress from condensation.

Unichiller Operation Manual, page 28

Selection & Integration Q&A

When should I choose the Unichiller 022w instead of a sibling model like the Unichiller 015?

Choose the 022w when a water-cooled condenser is preferred and the facility can supply cooling water at 5–20 °C and 1–6 bar. The 015 siblings are air-cooled (no cooling-water connections) and have a higher noise level of 63 dB(A) versus 60 dB(A) for the 022w. Select the 022w for lower noise or where air-cooled heat rejection is impractical.

What are the requirements for the cooling-water supply and process loop connections?

Cooling water: G1/2 male connections, inlet temperature 5–20 °C, differential pressure min. 1 bar, max. 6 bar, flow about 77–96 l/h depending on conditions. Process loop: G3/4 AG male pump connections; use hoses rated for the pressure and temperature, and do not exceed maximum tightening torques. The unit is for externally closed applications only.

What maintenance and accessories are required beyond the base unit?

The base delivery includes a power cable with country-specific plug (must be specified at ordering). No process hoses or cooling-water fittings are included; these must be sourced separately. Refrigerant circuit work requires approved contractors. Regular maintenance includes checking cooling-water circuit and cleaning; no specific interval is given in the provided documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF