Peter Huber Kältemaschinenbau Unichiller P010-H OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P010-H OLÉ

Peter Huber Kältemaschinenbau Unichiller P010-H OLÉ — Recirculating chillers with Noise level 57 dB.

The Unichiller P010-H OLÉ is an air-cooled, CFC/HCFC-free recirculating chiller with a plastic pump (type B, non-adjustable) and G3/4 male connections, rated -20 to 100 °C. Its 'P' designation targets externally closed loops with high pressure drop, where the pump still delivers 6 l/min at 2.0 bar. It serves as a closed-circuit cooling source for process equipment requiring controlled coolant temperature.

Noise level
57 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P010-H OLÉ Current 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 57 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 53 kg
Electrical, Power & Drive Specifications
Fuse rating 16 A
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Hydraulic and thermal behavior

Installation, control and operation

Integration & Operating Notes

Process Limits
Cold-end capacity collapses below -10 °C

Cooling capacity falls to 0.5 kW at -10 °C and only 0.15 kW at -20 °C, so processes needing sustained load near the lower limit must be sized with margin or accept long pull-down times; the 1 kW figure applies only at 15 °C.

Unichiller P010-H OLÉ Datasheet, Specifications
Cooling & Media
Plastic pump incompatible with acetone and polyglycols

The type B plastic pump is not resistant to acetone or polyglycols (depending on manufacturer), so these fluids must be avoided or a more resistant plastic specified; for sub-zero operation water should be mixed with glysantine or ethylene glycol for freeze protection.

Unichiller P010-H OLÉ Datasheet, Specifications
Electrical
Do not combine -5% voltage with +2% frequency

Supply must stay within ±5% voltage and ±2% frequency, but the specific combination of -5% voltage and +2% frequency is explicitly not allowed; the circuit must also carry 14.5 A maximum with a 16 A fuse, and the country-specific plug must be stated at ordering.

Unichiller P010-H OLÉ Datasheet, Specifications
Mounting
Keep 50-200 cm side clearance for maintenance

Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance access, and the air-cooled condenser needs sufficient room ventilation; the unit is IP20 and must be used indoors at 5-40 °C ambient with at least 300 lx illuminance.

Unichiller Operation Manual, Installation
Mounting
Not permitted inside an ATEX zone

The unit is not explosion-protected and must not be installed or started up within an ATEX zone; refrigerant charge versus room size must also be checked against the limit per m³ of ambient air at the installation site.

Unichiller Operation Manual, Foreword/Installation
Process Limits
Externally closed circuits only

The chiller is designed for externally closed applications, so open baths or circuits that expose the coolant to atmosphere are outside its intended use; the 'P' model designation additionally suits loops with high pressure drop, where flow falls to 6 l/min at 2.0 bar.

Unichiller Operation Manual, Function Description
Control & I/O
Configure power-failure response before unattended runs

The power-failure response can be set to OFF/Standby, ON or Power Failure Auto via the controller; for exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles.

Unichiller Operation Manual, Normal Operation
Maintenance
Refrigerant circuit work restricted to approved contractors

Any work on the coolant/refrigerant circuit must be carried out by approved refrigeration and air-conditioning system contractors; the unit's DIN 12876 safety classification (III/FL) depends on whether the thermal fluid is combustible and is stated on the data sheet.

Unichiller Operation Manual, Maintenance/Compliance

Selection & Integration Q&A

When should I choose the P010-H OLÉ instead of a Unichiller 015 variant?

Pick the P010-H OLÉ for high-pressure-drop, externally closed loops: its 'P' designation suits such applications and it runs at 57 dB(A) versus 63 dB(A) for the 015 siblings. Choose a 015 variant when higher cooling capacity or a larger frame is needed.

What must the external circuit and its connections provide to mate with this chiller?

The pump connection is G3/4 male, so hoses/fittings must be G3/4 female, counterheld and tightened to the manual's torque limits. The circuit must be externally closed, hold at least 3.8 l fill, and its pressure drop should be checked against the pump curve (6 l/min at 2.0 bar).

What site and duty-cycle limits apply to installing this unit?

Indoors only, 5-40 °C ambient, IP20, at least 300 lx illuminance and up to 2000 m altitude; not in an ATEX zone. Allow 50-200 cm side clearance for maintenance, ensure room ventilation for the air-cooled condenser, and activate leveling feet/parking brakes before start-up.

What maintenance and delivery items should be planned beyond the base unit?

Refrigerant-circuit service must be done by approved refrigeration contractors; the DIN 12876 safety class (III/FL) depends on the fluid chosen. The unit ships with a power cable and country-specific plug only if specified at ordering; coolant (water plus glysantine or ethylene glycol) and mating G3/4 fittings are not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P010-H OLÉ Datasheet
Datasheet ·111,4 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF