Peter Huber Kältemaschinenbau Unichiller P010w-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P010w-H

Peter Huber Kältemaschinenbau Unichiller P010w-H — Recirculating chillers.

The Unichiller P010w-H is a water-cooled recirculating chiller with a plastic pump (type B) and Pilot ONE controller, covering -20 to 100 °C. Its 'P' designation marks it for high-pressure-drop applications, distinguishing it from standard Unichiller siblings. It serves externally closed cooling circuits requiring stable temperature control.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P010w-H Current —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 56 kg (net)
Electrical, Power & Drive Specifications
Fuse rating 16 A
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible)
Cooling water connection G1/2 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The P010w-H is a water-cooled chiller in the Unichiller series, using refrigerant R-449A (GWP 1397, CO2 equivalent 0.3 t). Unlike the air-cooled Unichiller 015 variants, this model requires a cooling water supply (G1/2 male connections, 1 bar minimum differential pressure, 6 bar maximum). The 'P' in the model name indicates suitability for applications with high pressure drops, per the operation manual. The pump is a non-adjustable plastic type B with G3/4 AG male connections, delivering 21 l/min at 0.5 bar but only 6 l/min at 2.0 bar, so system pressure drop directly reduces flow.

Operating behavior

Temperature range is -20 to 100 °C. Cooling capacity decreases as cooling water temperature rises, and required cooling water flow may increase. The unit is designed for cooling water intake temperatures of 5 to 20 °C; if below the condensation point, cooling water pipes must be insulated. For freeze protection below 0 °C, mix water with glysantine or ethylene glycol. The plastic pump is not resistant to acetone or polyglycols. Ambient temperature must remain 5 to 40 °C. The Pilot ONE controller supports power-failure response modes (OFF/Standby, ON, Power Failure Auto) and a Process Safety mode that releases maximum cooling capacity when the overtemperature trigger is reached.

Installation and operation

Electrical supply is 220-240 V 1~/2~ 50/60 Hz with a 16 A fuse; three-phase devices under 63 A are supplied with cable but without plug. Protection rating is IP20, so the unit must be installed indoors in a dry environment, at least 300 lx illuminance, up to 2000 m altitude, and not in an ATEX zone. A wall clearance of 50 to 200 cm per side is required for maintenance. Leveling feet or parking brakes must be engaged before operation. Cooling water supply must be shut off even for short downtimes. Electrical lines directly below the unit must be protected against liquid ingress from condensation. Refrigerant circuit work must be performed by approved refrigeration contractors.

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow maintenance access. The unit must be placed indoors with at least 300 lx illuminance and at an altitude not exceeding 2000 m. Leveling feet or parking brakes must be engaged before startup to prevent movement.

Operation Manual, Section 'Setup Mode' (page 25
Cooling & Media
Cooling water must be 5–20 °C and 1–6 bar differential

The cooling water supply must provide a minimum differential pressure of 1 bar and must not exceed 6 bar. Intake temperature should be between 5 and 20 °C; if below the condensation point, insulate the cooling water pipes. Cooling capacity drops and flow demand may rise as water temperature increases. Shut off cooling water even for overnight downtime.

Datasheet, page 2; Operation Manual, page 28
Electrical
Three-phase units under 63 A come without a plug

The unit is supplied with a cable but no plug for three-phase configurations with current consumption below 63 A. The installer must provide a suitable plug and connection. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%. Electrical lines directly below the unit must be protected against liquid ingress from condensation.

Datasheet, page 2; Operation Manual, page 28
Process Limits
Plastic pump is incompatible with acetone and polyglycols

The standard plastic pump (type B) is not resistant to acetone or polyglycols. If these fluids are required, a more resistant pump must be ordered. For freeze protection below 0 °C, use a water/glysantine or water/ethylene glycol mixture. The unit is intended only for externally closed applications.

Datasheet, page 2; Operation Manual, page 34
Control & I/O
Configure power-failure response to match process risk

The Pilot ONE controller allows power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles. Choose the mode that prevents runaway temperatures on power loss.

Operation Manual, pages 18–19
Maintenance
Refrigerant circuit work requires certified contractors

Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A has a GWP of 1397 and a CO2 equivalent of 0.3 t, so environmental compliance and leak checks apply. Check refrigerant charge against room size to avoid exceeding the limit per m³.

Operation Manual, page 17; Datasheet, page 1

Selection & Integration Q&A

When should I choose the P010w-H over the Unichiller 015 or 015-H variants?

Choose the P010w-H for high-pressure-drop applications (P in model name) and when water cooling is available. The 015 variants are air-cooled and lack the P designation, so they suit lower pressure-drop loops without a cooling water supply.

What are the requirements for the cooling water supply and the process loop connections?

Cooling water: G1/2 male connections, 1 bar min differential pressure, 6 bar max, 5–20 °C intake. Process loop: G3/4 AG male pump connections; use hoses rated for the pressure and counterhold fittings to the maximum tightening torque.

What are the installation environment and duty-cycle limits?

Install indoors, 5–40 °C ambient, at least 300 lx, max 2000 m altitude, not in ATEX zones. Maintain 50–200 cm side clearance. IP20 requires a dry location. Shut off cooling water even for overnight downtime.

What maintenance is required and what accessories are not included?

Refrigerant circuit work only by certified contractors. No plug is included for three-phase units under 63 A. Freeze protection fluid (glysantine or ethylene glycol) must be added by the user. Insulation for cooling water pipes may be needed if condensation occurs.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P010w-H Datasheet
Datasheet ·18,6 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF