Peter Huber Kältemaschinenbau Unichiller P012 OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P012 OLÉ

Peter Huber Kältemaschinenbau Unichiller P012 OLÉ — Recirculating chillers with Noise level 59 dB.

The Unichiller P012 OLÉ is a recirculating chiller with a plastic circulation pump (type B, non-adjustable) and G3/4 AG male connections, designed for externally closed applications with high pressure drop. Its -20…40 °C range and 220–240 V 1~/2~ 50/60 Hz supply distinguish it from higher-capacity siblings such as the Unichiller 015 series. It serves as a compact cooling source for process loops requiring stable temperature control via the OLÉ controller.

Noise level
59 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P012 OLÉ Current 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 59 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 59 kg (net)
Electrical, Power & Drive Specifications
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The P012 OLÉ is a free-standing, air-cooled recirculating chiller in the Unichiller series. Its 'P' designation indicates suitability for applications with high pressure drop, per the operation manual. The plastic circulation pump (type B) is not speed-adjustable and terminates in G3/4 AG male threads. Compared with sibling models like the Unichiller 015 (63 dB(A)), this unit is quieter at 59 dB(A), but shares the same controller family. The OLÉ controller provides an OLED display with 0.1 K resolution and USB (Device) plus RS232 interfaces. The unit is rated IP20 and safety class I / NFL.

Behavior under load and media constraints

Cooling capacity is rated at 20 °C room temperature and drops as ambient temperature rises. The temperature range is -20…40 °C, but the plastic pump is not resistant to acetone or polyglycols, so these media must be avoided or a more resistant pump specified. For freeze protection, the manufacturer recommends water mixed with glysantine or ethylene glycol. The unit is intended only for externally closed applications; it is not explosion-protected and must not be installed in an ATEX zone. Refrigerant is R-290 (A3, H220), requiring attention to room volume and charge limits.

Installation, control and operation

Installation requires a minimum ambient temperature of 5 °C and maximum of 40 °C, indoors with illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance. The power supply is 220–240 V 1~/2~ 50/60 Hz; voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and mismatched combinations are not allowed. Single- and two-phase devices are supplied with a power cable and country-specific plug that must be specified at ordering. The power-failure response can be configured as OFF/Standby, ON, or Power Failure Auto. Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached. Leveling feet must be activated and parking brakes applied before operation.

Integration & Operating Notes

Process Limits
Avoid acetone and polyglycols with standard plastic pump

The plastic circulation pump is not resistant to acetone or polyglycols (depending on manufacturer). Using these media will damage the pump and void performance. For such fluids, a more resistant pump must be ordered or the process loop isolated.

Unichiller P012 OLÉ Technical Data Sheet, page 2
Electrical
Voltage and frequency tolerances must be matched

A -5% voltage combined with +2% frequency is not allowed. The supply must stay within ±5% voltage and ±2% frequency simultaneously to comply with EN60034-1. Verify site power quality before commissioning.

Unichiller P012 OLÉ Technical Data Sheet, page 2
Mounting
Maintain 50–200 cm wall clearance per side

Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access and air flow. Insufficient clearance will obstruct service and may reduce cooling capacity.

Unichiller Operation Manual, page 25
Process Limits
Use only in externally closed circuits

The unit is designed for externally closed applications. Open baths or unsealed loops will cause evaporation, contamination and poor temperature stability. Ensure the process circuit is sealed and compatible with the pump materials.

Unichiller Operation Manual, page 34
Safety
Configure power-failure response for process safety

The power-failure response can be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, select Process Safety mode so that maximum cooling is released when the overtemperature trigger is reached, preventing runaway.

Unichiller Operation Manual, pages 18–19
Maintenance
Refrigerant circuit work requires certified contractors

Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. Unauthorized intervention with R-290 (A3, H220) is hazardous and voids compliance.

Unichiller Operation Manual, page 17
Installation
Specify country-specific plug at ordering

Single- and two-phase devices are delivered with a power cable and country-specific plug only if specified at ordering. Without this, commissioning will require a locally sourced plug, which may affect warranty.

Unichiller P012 OLÉ Technical Data Sheet, page 2

Selection & Integration Q&A

When should I choose the P012 OLÉ over a Unichiller 015 variant?

Choose the P012 OLÉ for lower noise (59 dB(A) vs 63 dB(A)) and high-pressure-drop applications. The 015 series offers higher capacity but is louder. Select the 015 if your heat load exceeds the P012's capacity; the P012 is preferable for space-constrained or noise-sensitive installations.

What are the requirements for connecting the P012 OLÉ to my process loop?

The pump connection is G3/4 AG male. Use hoses or fittings rated for -20…40 °C and compatible with water/glycol mixtures. Do not exceed maximum tightening torque and counterhold connections. The circuit must be externally closed; avoid acetone and polyglycols unless a special pump is fitted.

What ambient and installation limits apply to the P012 OLÉ?

Install indoors at 5…40 °C ambient, illuminance ≥300 lx, altitude ≤2000 m. Maintain 50–200 cm wall clearance per side. IP20 requires a dry location. Do not install in ATEX zones. Leveling feet must be activated and parking brakes applied before start-up.

What maintenance and accessories are required beyond the base unit?

The base delivery includes the chiller and, for single/two-phase, a power cable with country-specific plug only if specified. Refrigerant circuit work must be by certified contractors. Regular maintenance includes checking pump connections for leaks and ensuring cooling water supply is shut off during downtimes. No consumables are listed in the provided documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P012 OLÉ Technical Data Sheet
Datasheet ·102,4 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF