Peter Huber Kältemaschinenbau Unichiller P015-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P015-H

Peter Huber Kältemaschinenbau Unichiller P015-H — Recirculating chillers with Noise level 63 dB.

The Unichiller P015-H is a recirculating chiller with a 'P' designation for high-pressure-drop applications, rated -20 to 100 °C and cooled by flammable R-290 refrigerant. It delivers 1.5 kW at 15 °C falling to 0.3 kW at -20 °C, and its 25 l/min, 2.5 bar pump serves externally closed loops.

Noise level
63 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P015-H Current 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 63 dB(A)
Maximum delivery flow rate 25 l/min (pressure pump max; also 2, 5 bar)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 62 kg
Electrical, Power & Drive Specifications
Fuse rating 16 A
Power supply 220-240V 1~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Externally closed circuits only; no open bath duty

The manual restricts this chiller to externally closed applications, so the hydraulic circuit must be a sealed loop with an expansion volume of 1.7 l and a minimum fluid charge of 3.8 l; open tanks or atmospheric vessels are outside the intended use.

Unichiller Operation Manual, Function Description, p. 34
Process Limits
Low-temperature capacity collapses below -10 °C

Cooling capacity falls from 1.5 kW at 15 °C to 0.3 kW at -20 °C, so processes with sustained cold loads near the lower end of the -20...100 °C range must be sized against the actual setpoint capacity, not the 15 °C figure.

Unichiller P015-H Datasheet, Technical Specifications, p. 1
Electrical
Voltage tolerance only valid with matched frequency tolerance

A ±5% voltage deviation is allowed only with a simultaneous ±2% frequency tolerance, and some combinations are not allowed; verify the site supply against both before connection, since the unit draws up to 15.5 A on a 16 A fuse.

Unichiller P015-H Datasheet, Technical Specifications, p. 2
Electrical
Country-specific plug must be ordered with the unit

Single-phase devices are supplied with a power cable and a country-specific plug that must be specified at ordering; confirm the plug type for the installation country so commissioning is not delayed by a missing or wrong connector.

Unichiller P015-H Datasheet, Technical Specifications, p. 2
Mounting
R-290 charge limits the permissible room size

The refrigerant is R-290 (A3, H220), a flammable natural refrigerant; the charge stated on the rating plate and the room size must be checked at installation so the refrigerant limit per m³ of ambient air is not exceeded, and ignition sources must be controlled.

Unichiller Operation Manual, Installation, p. 15
Mounting
Keep 50-200 cm clearance per side for service

Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access; the unit must also be installed indoors at 5-40 °C ambient, at least 300 lx illuminance and no higher than 2000 m altitude.

Unichiller Operation Manual, Installation, p. 25
Mounting
Not permitted inside an ATEX zone

The unit is not explosion-protected and must not be installed or started up within an ATEX zone; this constrains siting whenever the chiller serves a process area classified for flammable atmospheres.

Unichiller Operation Manual, Foreword, p. 13
Process Media
Counterhold G3/4 fittings and respect torque limits

The pump connection is G3/4 male; hoses and fittings must match this thread, connections must be counterheld during tightening, and the maximum torques in the manual table must not be exceeded to avoid damage and leaks.

Unichiller Operation Manual, Commissioning, p. 28
Control & I/O
Choose power-failure response before unattended runs

The Pilot ONE can be configured for OFF/Standby, ON or Power Failure Auto after a mains failure; the selected behavior determines whether the process restarts automatically, so it must be set deliberately for each application.

Unichiller Operation Manual, Normal Operation, p. 19
Control & I/O
Process Safety mode applies cooling instead of tripping

In Process Safety mode the controller releases maximum cooling capacity when the adjustable overtemperature trigger per DIN 12876 is reached, rather than switching off all poles; select this mode only where full cooling at the OT limit is safe for the process.

Unichiller Operation Manual, Normal Operation, p. 18
Maintenance
Refrigerant circuit work requires certified contractors

Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; plan service access and contracts accordingly, since the R-290 circuit cannot be serviced by general maintenance staff.

Unichiller Operation Manual, Maintenance, p. 17
Maintenance
Shut off cooling water even for overnight stops

The cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion; electrical lines directly below a water-cooled unit must also be protected against liquid ingress from condensation.

Unichiller Operation Manual, Commissioning, p. 28

Selection & Integration Q&A

When should I choose the P015-H over the Unichiller 015 or 015-H siblings?

Pick the P015-H when the process loop has a high pressure drop: the 'P' model is specifically suited to such applications, and its pump reaches 2.5 bar at up to 25 l/min. The plain 015 and 015-H share the same 63 dB(A) class but not this high-pressure-drop pump characteristic.

What must the adjacent hydraulic circuit and power supply provide for this chiller?

The loop must be externally closed with at least 3.8 l fill and 1.7 l expansion volume, mated to the G3/4 male pump port with counterheld fittings. Supply must be 220-240 V 1~ 50 Hz, 16 A fuse, with ±5% voltage only alongside ±2% frequency tolerance.

Where can the unit be installed and how must it be secured before start-up?

Indoors only, 5-40 °C ambient, at least 300 lx, up to 2000 m altitude, with 50-200 cm wall clearance per side and no ATEX zone. Before switching on, activate parking brakes and/or unscrew the leveling feet so the unit cannot move.

What maintenance and delivery items should be planned beyond the base unit?

Refrigerant circuit work needs approved refrigeration contractors, and the country-specific plug must be specified at ordering since the cable is supplied with it. Cooling water must be shut off for even overnight stops; plan service access of 50-200 cm per side.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P015-H Recirculating Chiller Datasheet
Datasheet ·167,9 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF