Peter Huber Kältemaschinenbau Unichiller P025w OLÉ
Peter Huber Kältemaschinenbau Unichiller P025w OLÉ — Recirculating chillers with Noise level 60 dB.
The Unichiller P025w OLÉ is a water-cooled recirculating chiller with a plastic pump and OLÉ controller, rated 2 kW at 0 °C over a -10…40 °C range. Its 'P' designation targets process loops with high pressure drop, distinguishing it from the 015 siblings. It serves externally closed cooling circuits requiring 208–230 V 1~/2~ 60 Hz supply.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P025w OLÉ Current | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
Full specifications
| Noise level | 60 dB(A) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| Temperature range | -10...40 °C |
| Weight | 66 kg |
| Fuse rating | 16 A |
| Power supply | 208-230V 1~/2~ 60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 2 kW (at 0 °C) |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 72 л/час (at 15°C, flow -10°C) at 15°C, flow 0°C: 84 l/h · at 15°C, flow 15°C: 84 l/h |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit using R-449A (A1, H280; 0.43 kg, 0.6 t CO2e) with a non-adjustable plastic pump (type B) and G3/4 AG male pump connection.
- The 'P' in the model name marks this unit as suited to applications with high pressure drop; the 015/015-H/015 OLÉ siblings in the series are the alternative when that condition is absent.
- Cooling-water side uses G1/2 male connections; internal wetted materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.
- IP20, Class I/NFL, 66 kg; OLED display with 0.1 K resolution; USB (Device) and RS232 interfaces.
Behavior and media
- Rated cooling capacity 2 kW at 0 °C, valid only at 20 °C room temperature, 15 °C cooling-water inlet and 1 bar differential pressure; higher cooling-water temperature reduces capacity.
- Cooling-water consumption is 72 l/h at -10 °C flow and 84 l/h at 0 °C and 15 °C flow, all at 15 °C inlet.
- Cooling-water inlet must stay between 5 °C and 20 °C; below the condensation point the internal cooling-water pipes require insulation.
- The plastic pump is not resistant to acetone or polyglycols; water with glycine or ethylene glycol is recommended for freeze protection.
- Minimum filling capacity 3.8 l; expansion tank 1.7 l.
Installation, control and operation
- Supply 208–230 V 1~/2~ 60 Hz, 16 A fuse, max current 12.5 A; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and certain combinations (e.g. -5% voltage with +2% frequency) are not permitted.
- Three-phase devices below 63 A are delivered with cable but without plug; a suitable plug must be provided on site.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto via the Pilot ONE; Process Safety mode releases maximum cooling capacity when the OT trigger is reached instead of switching off all poles.
- Leveling feet must be activated and parking brakes applied before start-up; cooling water must be shut off even for overnight downtimes.
Integration & Operating Notes
The unit is designed for cooling-water intake between 5 °C and 20 °C. If the inlet falls below the condensation point, the cooling-water pipes inside the unit must be insulated to prevent condensate formation and electrical hazard.
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed. Check site power quality against this envelope before commissioning.
Three-phase devices with current consumption below 63 A are delivered with cable but without plug. A suitable plug must be procured and fitted on site before the unit can be connected to the 208–230 V supply.
Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude.
Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. Route cables and install adjacent equipment so that dripping condensate cannot reach live parts.
The unit is designed for externally closed applications only. The hydraulic circuit must be laid out accordingly, with a minimum filling capacity of 3.8 l and the 1.7 l expansion tank accounted for when charging the loop.
The plastic pump is not resistant to acetone or polyglycols (depending on the manufacturer). For freeze protection, use water with glycine or ethylene glycol instead, and verify compatibility with the copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM wetted materials.
The cooling-water supply must be shut off even for shorter downtimes such as overnight to prevent water damage and corrosion during idle periods. Establish this as a routine in the operating procedure.
Work on the coolant circuit must only be carried out by approved refrigeration/air-conditioning system contractors. Plan service access and contracts accordingly, since the R-449A charge of 0.43 kg (0.6 t CO2e) is a regulated refrigerant.
The power-failure response can be set to OFF/Standby, ON or Power Failure Auto via the Pilot ONE. For exothermic processes, Process Safety mode releases maximum cooling capacity when the OT trigger value is reached instead of switching off all poles.
Parking brakes must be activated at the casters (if any) and/or the leveling feet unscrewed/activated before the unit is put into operation, to prevent the unit from moving and causing crushing injuries.
Selection & Integration Q&A
Choose the P025w OLÉ when the process loop has high pressure drop, since the 'P' designation marks units particularly suited to such applications. The 015 siblings are the alternative when that condition is absent; note their published noise level is 63 dB(A) versus 60 dB(A) here.
Provide cooling water at 5–20 °C inlet with 1–6 bar differential pressure and G1/2 male mating connections; consumption is 72–84 l/h depending on flow temperature. Electrically, supply 208–230 V 1~/2~ 60 Hz through a 16 A fuse (max 12.5 A) and fit a plug on site, as the cable is delivered without one.
Indoors only, at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance. It must not be placed in an ATEX zone; activate parking brakes and/or leveling feet before start-up, and protect electrical lines below the unit from condensate.
Refrigerant-circuit work is restricted to approved refrigeration contractors; shut off cooling water even overnight. The base delivery includes the cable but no plug, and no heat-transfer fluid: charge the loop with at least 3.8 l of water plus glycine or ethylene glycol, avoiding acetone and polyglycols.