Peter Huber Kältemaschinenbau Unichiller 022w OLÉ
Peter Huber Kältemaschinenbau Unichiller 022w OLÉ — Recirculating chillers with Noise level 60 dB.
The Unichiller 022w OLÉ is a water-cooled recirculating chiller with an immersion pump and OLÉ controller, covering -10 to 40 °C. It is the smallest OLÉ variant in the Unichiller series, distinguished by its 60 dB(A) noise level and G3/4 pump connection. It serves externally closed cooling circuits requiring a 1–6 bar cooling water supply.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 022w OLÉ Current | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Noise level | 60 dB(A) |
| Maximum delivery flow rate | 29 l/min (pressure pump max 1 bar) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | Immersion pump |
| Temperature range | -10...40 °C |
| Weight | 60 kg |
| Current consumption | 6 A (max) |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~ 50Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 77 л/час (at 15°C, flow -10°C) at 15°C, flow 0°C: 96 l/h · at 15°C, flow 15°C: 95 l/h |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The 022w OLÉ is a water-cooled (w) recirculating chiller with an immersion pump and the OLÉ controller; it is the smallest OLÉ model in the Unichiller series, with siblings 015, 015-H, 015-H OLÉ and 015 OLÉ all rated at 63 dB(A) versus 60 dB(A) here.
- The hydraulic circuit uses a plastic immersion pump with G3/4 male pump connection and G1/2 male cooling-water connection; the pump speed is not adjustable.
- The refrigerant is R-290 (propane, A3, H220) with a charge of 0.16 kg; the unit is not explosion-protected and must not be installed in an ATEX zone.
Behavior and media
- Temperature range is -10 to 40 °C with 0.1 K display resolution on an OLED display; the unit is intended only for externally closed applications.
- Cooling water consumption depends on the required flow temperature: 77 l/h at -10 °C, 96 l/h at 0 °C and 95 l/h at 15 °C, all at a 15 °C cooling-water intake; cooling power drops and flow demand may rise as cooling-water temperature increases.
- The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol.
Installation, control and operation
- The OLÉ controller provides USB (Device) and RS232 interfaces; the power-failure response is configurable (OFF/Standby, ON, or Power Failure Auto), and Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.
- Electrical supply is 220–240 V 1~ 50 Hz, max 6 A, with a 16 A fuse; voltage tolerance is ±5% with ±2% frequency tolerance, but combinations such as -5% voltage and +2% frequency are not allowed.
- The unit is IP20 and must be operated indoors at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude; a wall clearance of 50–200 cm per side is required for maintenance.
Integration & Operating Notes
The cooling-water circuit requires a minimum differential pressure of 1 bar and must never exceed 6 bar; undersupply reduces cooling capacity, while overpressure can damage the internal copper/stainless/EPDM circuit. Verify the supply pressure at the unit inlet, not at the building header.
The unit is designed for cooling-water intake temperatures of 5–20 °C; if the intake temperature falls below the condensation point of the ambient air, the cooling-water pipes inside the unit must be insulated to prevent condensate formation and electrical hazard.
Voltage tolerance is ±5% with a simultaneous frequency tolerance of ±2%, but the combination of -5% voltage and +2% frequency is not permitted; check site power quality against this rule before commissioning, as the 16 A fuse protects the 6 A maximum current draw.
Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow service access to the refrigerant circuit and pump; also confirm room volume against the 0.16 kg R-290 charge to stay below the refrigerant limit per m³ of ambient air.
Close the cooling-water supply to the unit for any downtime, including overnight, to prevent water damage and corrosion in the cooling circuit; this is separate from the electrical power-failure response setting.
The OLÉ controller can be set to OFF/Standby, ON, or Power Failure Auto after a mains failure; for exothermic processes, Process Safety mode releases maximum cooling when the overtemperature trigger is reached instead of switching off all poles, so the trigger value must be set to match the process.
Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the R-290 charge of 0.16 kg and the A3 classification require qualified handling and are not user-serviceable.
Selection & Integration Q&A
Pick the 022w OLÉ for the lowest noise in the series (60 dB(A) vs 63 dB(A) on all 015 variants) and for water cooling with the OLÉ controller. The 015-H models add a heater; the 015 base models differ in cooling capacity. Confirm your heat load and required flow temperature before deciding.
Provide cooling water at 5–20 °C intake with 1 bar minimum differential pressure and 6 bar maximum, connected via G1/2 male fittings. Consumption is 77–96 l/h depending on flow temperature. Use water compatible with copper, stainless 1.4401, MS, PA, PPE, PTFE and EPDM to avoid corrosion.
Indoors only, at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude. It is IP20 and not explosion-protected, so no ATEX zone. Leave 50–200 cm clearance per side for maintenance and check room volume against the 0.16 kg R-290 charge.
The Pt100 sensor connection for process temperature display is factory-fitted only and must be ordered with the unit. Matching G3/4 male pump and G1/2 male cooling-water hose couplings are not supplied. Refrigerant-circuit service requires approved contractors; plan cooling-water shutoff for every downtime.