Peter Huber Kältemaschinenbau Unichiller 025T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 025T

Peter Huber Kältemaschinenbau Unichiller 025T — Recirculating chillers with Noise level 74 dB.

The Unichiller 025T is an air-cooled, single-phase recirculating chiller rated -10 to 40 °C with 2.5 kW cooling at 15 °C, distinguishing it from lower-capacity 015 siblings by its 25 l/min pump and 74 dB(A) sound level. It serves externally closed process loops requiring stable coolant temperature within a 230 V/50 Hz industrial supply.

Noise level
74 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 025T Current 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 74 dB(A)
Expansion volume 2 l
Maximum delivery flow rate 25 l/min (pressure pump max; also 3 bar)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 144 kg
Electrical, Power & Drive Specifications
Current consumption 11 A (max)
Fuse rating 16 A
Power supply 230V 1~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The Unichiller 025T is a free-standing, air-cooled recirculating chiller in the Unichiller series. Unlike the 015 siblings (63 dB(A)), this 025T model delivers higher cooling capacity and a 25 l/min pump flow, making it the larger modification for processes with greater heat loads. The unit uses R-449A refrigerant (A1, H280; GWP 1397) and is classified as pressure equipment Art. 4.3 PED. It is intended only for externally closed applications; models with 'P' in the name are for high pressure-drop loops, which this model is not.

Behavior under load and media

Cooling capacity is strongly temperature-dependent: 2.5 kW at 15 °C, 1.2 kW at 0 °C, and 0.6 kW at -10 °C, all valid at 20 °C room temperature. The operating range is -10 to 40 °C. The pump provides up to 25 l/min at 3 bar and is not speed-adjustable. The hydraulic circuit has a minimum filling capacity of 2.5 l and an expansion volume of 2 l. The unit is air-cooled; rising ambient temperature reduces cooling capacity, and the permitted ambient range is 5 to 40 °C.

Installation, control and operation

The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable (OFF/Standby, ON, Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles. Electrical supply is 230 V 1~ 50 Hz with max. current 11 A and a 16 A fuse; voltage tolerance ±5 % and frequency ±2 % are permitted but not simultaneously in the same direction. The pump connection is G3/4 male. Protection rating is IP20, so indoor dry location is required. Sound pressure level is 74 dB(A) ±4 dB(A). A country-specific plug must be specified at ordering.

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance access to the refrigerant circuit and components. Planning the footprint without this clearance will obstruct service work and may prevent proper airflow for the air-cooled condenser.

Unichiller Operation Manual, page 25
Electrical
Verify supply quality within combined voltage/frequency tolerance

The unit accepts ±5 % voltage and ±2 % frequency deviation, but not simultaneously in the same direction. A supply that is both high-voltage and high-frequency (or both low) may exceed the permissible envelope and must be corrected before connection to avoid damage or invalid operation.

Unichiller 025T Technical Data, page 2
Process Limits
Size external loop for 2.5 l minimum fill and 2 l expansion

The external circuit must be filled to at least 2.5 l and the expansion volume is 2 l. Underfilling risks pump cavitation and poor temperature stability; overfilling beyond the expansion allowance can cause pressure relief and fluid loss. Calculate loop volume including hoses and process heat exchanger before commissioning.

Unichiller 025T Technical Data, page 1
Cooling & Media
Cooling capacity valid at 20 °C room temperature only

The published capacities (2.5 kW at 15 °C, 1.2 kW at 0 °C, 0.6 kW at -10 °C) apply at 20 °C ambient. Higher ambient temperature reduces achievable cooling, so the installation site must stay within 5–40 °C and have adequate ventilation to avoid derating below the process heat load.

Unichiller 025T Technical Data, page 2
Safety
Configure Process Safety for exothermic runaway protection

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature trigger is reached, instead of switching off all poles. For exothermic reactions, this prevents temperature runaway on fault; for other processes, the alternative shutdown behavior may be preferred. The mode must be selected in the Pilot ONE configuration before operation.

Unichiller Operation Manual, page 18
Maintenance
Refrigerant circuit work requires certified contractor

Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The unit contains R-449A (GWP 1397), so leak detection, recovery and recharge must follow applicable regulations. In-house maintenance is limited to non-refrigerant tasks such as cleaning and fluid checks.

Unichiller Operation Manual, page 17
Installation
Specify country-specific mains plug at ordering

Single-phase devices are delivered with a power cable and a country-specific plug that must be stated when ordering. Failure to specify may result in a non-compatible plug, requiring replacement before commissioning and delaying installation.

Unichiller 025T Technical Data, page 2

Selection & Integration Q&A

When should I choose the Unichiller 025T over the 015 siblings?

Choose the 025T when the process heat load requires up to 2.5 kW at 15 °C and a 25 l/min pump flow; the 015 models offer lower capacity and 63 dB(A) noise. The 025T is also louder at 74 dB(A), so acoustic planning matters. For high pressure-drop loops, a 'P' model is needed instead.

What are the requirements for connecting the 025T to my process loop?

The pump connection is G3/4 male, so mating hoses/fittings must match this thread; counterhold connections and do not exceed maximum tightening torques. The external circuit must be externally closed, filled to at least 2.5 l, with 2 l expansion volume. A Pt100 external sensor can be connected for process control.

What ambient and duty-cycle limits apply to the 025T installation?

Install indoors only, at 5–40 °C ambient, with illuminance at least 300 lx and altitude up to 2000 m. Maintain 50–200 cm side clearance for maintenance. The unit is IP20 and not ATEX-rated, so it must not be in a hazardous zone. Cooling capacity is rated at 20 °C room temperature.

What maintenance and accessories are required beyond base delivery?

The base unit includes a country-specific plug only if specified at ordering. Refrigerant circuit work must be by approved contractors. No consumables or cables beyond the power cable are listed; the Pilot ONE interfaces (Ethernet, USB, RS232) require user-supplied cables. Regular cleaning of the air-cooled condenser is implied for performance.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 025T Technical Data
Datasheet ·92,4 КБ ·2 pp.
View PDF