Peter Huber Kältemaschinenbau Unichiller P007-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P007-H

Peter Huber Kältemaschinenbau Unichiller P007-H — Recirculating chillers.

The Unichiller P007-H is a recirculating chiller with a plastic pump and Pilot ONE controller, rated for -20 to 100 °C and specifically suited to high-pressure-drop applications. It delivers up to 25 l/min at 2.5 bar and 7 kW cooling at 15 °C, distinguishing it from lower-capacity siblings. It serves as a closed-loop cooling source for external processes requiring stable temperature control.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P007-H Current —Pilot ONEIII / FL-20–100——
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 58 kg
Interfaces, Connections & Control
Controller Pilot ONE
Operating Conditions, Environment & Protection
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and Series Positioning

The Unichiller P007-H is a free-standing recirculating chiller in the Unichiller series (up to 25 kW). Its 'P' designation indicates suitability for applications with high pressure drops, per the operation manual. Unlike sibling models such as the Unichiller 015, which are rated at 63 dB(A), the P007-H's noise level is not specified in the provided facts. The unit uses R-290 (A3, H220) refrigerant and is classified IP20, safety class III/FL. The pump connection is G3/4 male, and the unit weighs 58 kg.

Performance and Media Behavior

Cooling capacity is temperature-dependent: 7 kW at 15 °C, 5.5 kW at 0 °C, 4 kW at -10 °C, and 2 kW at -20 °C, valid at 20 °C room temperature. Capacity drops with rising ambient temperature. The circulation pump delivers up to 25 l/min and 2.5 bar, with flow decreasing as pressure rises. The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol. The unit is intended for externally closed applications only.

Installation, Control, and Operation

The Pilot ONE controller manages operation, including configurable power-failure response (OFF/Standby, ON, or Power Failure Auto) and Process Safety mode, which releases maximum cooling capacity when the overtemperature trigger is reached. The unit requires a 208-240 V 1~/2~ 50/60 Hz supply with max. 14 A and a 16 A fuse; voltage and frequency tolerances are coupled (±5% voltage only with ±2% frequency, and some combinations are not allowed). It must be installed indoors at 5-40 °C ambient, with at least 300 lx illuminance, up to 2000 m altitude, and not in an ATEX zone. Wall clearance of 50-200 cm per side is required for maintenance. Leveling feet or parking brakes must be engaged before operation. Cooling water supply (if applicable) must be shut off during downtimes.

Integration & Operating Notes

Process Limits
Do not use with acetone or polyglycols

The standard plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). Using these fluids may cause pump failure or leakage. If such fluids are required, a more resistant pump must be ordered or an alternative fluid selected.

Datasheet, Technical Specifications
Electrical
Voltage and frequency tolerances are coupled

The supply must remain within ±5% voltage only if frequency is within ±2%. Certain combinations, such as -5% voltage with +2% frequency, are not allowed. Verify site power quality before installation to avoid damage or malfunction.

Datasheet, Technical Specifications
Mounting
Maintain 50-200 cm wall clearance per side

For maintenance access, a wall clearance of 50 to 200 cm is required on either side of free-standing models. Insufficient clearance hinders service and may affect airflow. Plan the installation footprint accordingly.

Operation Manual, Section on Installation
Safety
Process Safety mode releases max cooling on OT trip

When the overtemperature protection trigger value is reached, Process Safety mode releases maximum cooling capacity instead of switching off all poles. This is critical for exothermic processes where loss of cooling could cause runaway. Configure the OT trigger accordingly.

Operation Manual, Section on Safety
Maintenance
Refrigerant circuit work requires certified contractors

Work on the coolant circuit must only be performed by approved refrigeration/air-conditioning system contractors. Unauthorized intervention risks refrigerant release (R-290 is flammable) and voids compliance. Schedule service accordingly.

Operation Manual, Section on Maintenance
Operation
Shut off cooling water during downtimes

Even for short downtimes such as overnight, the cooling water supply must be shut off to prevent water damage and corrosion. Implement a procedure or automatic valve to ensure this is done consistently.

Operation Manual, Section on Operation

Selection & Integration Q&A

When should I choose the Unichiller P007-H over other Unichiller models like the 015?

Choose the P007-H when the application has high pressure drop, as indicated by the 'P' in the model name. It offers up to 7 kW cooling at 15 °C and 25 l/min at 2.5 bar. The 015 series may be preferred for lower capacity or where noise level (63 dB(A)) is specified.

What are the requirements for connecting the P007-H to my process cooling circuit?

The pump connection is G3/4 male, so mating hoses and fittings must match this thread. Ensure the external circuit is closed and compatible with the plastic pump (avoid acetone and polyglycols). The pump delivers up to 25 l/min at 2.5 bar; verify the pressure drop of your circuit does not exceed this.

What are the ambient and installation limits for the P007-H?

Install indoors at 5-40 °C ambient, with at least 300 lx illuminance, up to 2000 m altitude, and not in an ATEX zone. Maintain 50-200 cm wall clearance per side. Engage leveling feet or parking brakes before operation. Cooling capacity drops as ambient temperature rises.

What maintenance and accessories are required for the P007-H that are not included in the base delivery?

The base delivery includes a power cable with country-specific plug (must be specified at ordering). No other accessories are mentioned. Maintenance includes regular checks of fluid level via sight glass and refrigerant circuit work by certified contractors. No specific service intervals are provided in the facts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P007-H Technical Data
Datasheet ·129,2 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF