Peter Huber Kältemaschinenbau Unichiller P010-H
Peter Huber Kältemaschinenbau Unichiller P010-H — Recirculating chillers with Noise level 57 dB.
The Unichiller P010-H is an air-cooled recirculating chiller with a plastic pump (type B, G3/4 male) and Pilot ONE controller, rated -20 to 100 °C. Its 'P' designation suits high-pressure-drop loops, delivering up to 25 l/min at 2.5 bar. Cooling capacity falls from 1 kW at 15 °C to 0.15 kW at -20 °C, so load must be checked at the coldest set point.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P010-H Current | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Noise level | 57 dB(A) |
| Maximum delivery flow rate | 25 l/min (pressure pump max; also 2, 5 bar) |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 58 kg |
| Current consumption | 14 A (max) |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~/2~ 50/60Hz V, Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and positioning
- Air-cooled refrigeration circuit using R-449A (A1, H280; GWP 1397), housed in a free-standing enclosure with casters and leveling feet.
- Plastic circulation pump type B, non-adjustable speed, G3/4 male connection; maximum delivery 25 l/min and maximum delivery pressure 2.5 bar.
- Pilot ONE controller with Ethernet, USB host/device and RS232; external Pt100 sensor input.
- Within the Unichiller series, the 'P' in the model name marks this unit as particularly suitable for applications requiring high pressure drops; sibling models 015/015-H/015 OLÉ are quieter (63 dB(A)) but do not carry the 'P' designation.
Behavior under load
- Operating temperature range -20 to 100 °C; cooling capacity is 1 kW at 15 °C and only 0.15 kW at -20 °C, so the thermal load must be verified at the lowest required set point.
- Output data are valid at 20 °C room temperature; higher ambient temperature may reduce cooling capacity.
- Pump curve: 25 l/min maximum, 2.5 bar maximum pressure, with flow dropping to 6 l/min at 2.0 bar.
- Minimum filling capacity 3.8 l; expansion volume 1.7 l.
Installation, control and operation
- Supply 220-240 V 1~/2~ 50/60 Hz, maximum current 14 A, 16 A fuse; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and -5% voltage with +2% frequency is not allowed.
- Single- and two-phase devices are supplied with a power cable and country-specific plug, which must be specified at ordering.
- Ambient temperature 5 to 40 °C; IP20; indoor use only at illuminance ≥300 lx and up to 2000 m altitude; not for ATEX zones.
- Wall clearance 50 to 200 cm per side for maintenance on free-standing models.
- Power-failure response configurable as OFF/Standby, ON, or Power Failure Auto via Pilot ONE; Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.
- For freeze protection, mix water with glysantine or ethylene glycol; the plastic pump is not resistant to acetone or polyglycols.
Integration & Operating Notes
Cooling capacity drops from 1 kW at 15 °C to 0.15 kW at -20 °C, so a load sized at mid-range will be undersized at the low end. Check the actual heat load against the capacity at the minimum operating temperature before selecting this model.
Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and combining -5% voltage with +2% frequency is explicitly not allowed. Verify the site supply quality before connection to avoid compressor or controller malfunction.
A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude; installation inside an ATEX zone is prohibited.
The unit is designed for externally closed applications only. Open baths or circuits that expose the fluid to atmosphere are outside the intended use and may cause contamination or pump damage.
The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). For sub-zero operation, mix water with glysantine or ethylene glycol for freeze protection rather than using pure water.
The Pilot ONE allows the power-failure response to be set as OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A (A1, H280; GWP 1397), and charge versus room size must be checked to avoid exceeding the refrigerant limit per m³ of ambient air.
Single- and two-phase devices are supplied with a power cable and country-specific plug, which must be specified when ordering. The pump connection is G3/4 male, so hoses and fittings must match this thread and maximum tightening torques must not be exceeded.
Selection & Integration Q&A
Choose the P010-H when the process loop has a high pressure drop, since the 'P' in the model name marks it as particularly suitable for such applications. The 015/015-H siblings are quieter (63 dB(A)) but lack this designation; select them when pressure drop is low and noise matters.
The pump connection is G3/4 male, so hoses and fittings must match this thread. The plastic pump delivers up to 25 l/min at 2.5 bar maximum, with flow dropping to 6 l/min at 2.0 bar; verify the external circuit pressure drop against this curve. The pump is not resistant to acetone or polyglycols.
Install indoors only, at 5–40 °C ambient, illuminance ≥300 lx, up to 2000 m altitude, and not in an ATEX zone. Maintain 50–200 cm wall clearance per side. Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient. Leveling feet or parking brakes must be applied before operation.
The base delivery includes a power cable with country-specific plug only if specified at ordering. Refrigerant circuit work must be performed by approved refrigeration contractors. For freeze protection, glysantine or ethylene glycol must be added to water. Minimum filling capacity is 3.8 l; expansion volume 1.7 l.