Peter Huber Kältemaschinenbau Unichiller P025w OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P025w OLÉ

Peter Huber Kältemaschinenbau Unichiller P025w OLÉ — Recirculating chillers with Noise level 60 dB.

The Unichiller P025w OLÉ is a water-cooled recirculating chiller with a plastic pump and OLÉ controller, rated 2 kW at 0 °C over a -10…40 °C range. Its 'P' designation targets process loops with high pressure drop, distinguishing it from the 015 siblings. It serves externally closed cooling circuits requiring 208–230 V 1~/2~ 60 Hz supply.

Noise level
60 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P025w OLÉ Current 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 60 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 66 kg
Electrical, Power & Drive Specifications
Fuse rating 16 A
Power supply 208-230V 1~/2~ 60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 2 kW (at 0 °C)
Cooling water connection G1/2 male
Cooling water consumption 72 л/час (at 15°C, flow -10°C)
at 15°C, flow 0°C: 84 l/h · at 15°C, flow 15°C: 84 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Cooling-water inlet must stay within 5–20 °C

The unit is designed for cooling-water intake between 5 °C and 20 °C. If the inlet falls below the condensation point, the cooling-water pipes inside the unit must be insulated to prevent condensate formation and electrical hazard.

Unichiller P025w OLÉ Technical Data, page 2
Electrical
Supply tolerance combinations are restricted

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed. Check site power quality against this envelope before commissioning.

Unichiller P025w OLÉ Technical Data, page 2
Electrical
Mating plug not supplied with the cable

Three-phase devices with current consumption below 63 A are delivered with cable but without plug. A suitable plug must be procured and fitted on site before the unit can be connected to the 208–230 V supply.

Unichiller P025w OLÉ Technical Data, page 2
Mounting
Keep 50–200 cm wall clearance per side for maintenance

Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude.

Unichiller Operation Manual, page 25
Mounting
Protect electrical lines below the unit from condensate

Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. Route cables and install adjacent equipment so that dripping condensate cannot reach live parts.

Unichiller Operation Manual, page 28
Process Limits
Only externally closed circuits are permitted

The unit is designed for externally closed applications only. The hydraulic circuit must be laid out accordingly, with a minimum filling capacity of 3.8 l and the 1.7 l expansion tank accounted for when charging the loop.

Unichiller Operation Manual, page 34; Technical Data, page 1
Cooling & Media
Plastic pump excludes acetone and polyglycols

The plastic pump is not resistant to acetone or polyglycols (depending on the manufacturer). For freeze protection, use water with glycine or ethylene glycol instead, and verify compatibility with the copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM wetted materials.

Unichiller P025w OLÉ Technical Data, page 2
Maintenance
Shut off cooling water even for overnight downtime

The cooling-water supply must be shut off even for shorter downtimes such as overnight to prevent water damage and corrosion during idle periods. Establish this as a routine in the operating procedure.

Unichiller Operation Manual, page 28
Maintenance
Refrigerant circuit work requires certified contractors

Work on the coolant circuit must only be carried out by approved refrigeration/air-conditioning system contractors. Plan service access and contracts accordingly, since the R-449A charge of 0.43 kg (0.6 t CO2e) is a regulated refrigerant.

Unichiller Operation Manual, page 17; Technical Data, page 1
Control & I/O
Configure power-failure response for the process risk

The power-failure response can be set to OFF/Standby, ON or Power Failure Auto via the Pilot ONE. For exothermic processes, Process Safety mode releases maximum cooling capacity when the OT trigger value is reached instead of switching off all poles.

Unichiller Operation Manual, pages 18–19
Mounting
Secure the unit against movement before start-up

Parking brakes must be activated at the casters (if any) and/or the leveling feet unscrewed/activated before the unit is put into operation, to prevent the unit from moving and causing crushing injuries.

Unichiller Operation Manual, page 31

Selection & Integration Q&A

When should I choose the P025w OLÉ instead of the Unichiller 015 OLÉ or 015-H OLÉ?

Choose the P025w OLÉ when the process loop has high pressure drop, since the 'P' designation marks units particularly suited to such applications. The 015 siblings are the alternative when that condition is absent; note their published noise level is 63 dB(A) versus 60 dB(A) here.

What must I provide on the cooling-water and electrical side to integrate this chiller?

Provide cooling water at 5–20 °C inlet with 1–6 bar differential pressure and G1/2 male mating connections; consumption is 72–84 l/h depending on flow temperature. Electrically, supply 208–230 V 1~/2~ 60 Hz through a 16 A fuse (max 12.5 A) and fit a plug on site, as the cable is delivered without one.

Where can the unit be installed and how must it be secured before operation?

Indoors only, at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance. It must not be placed in an ATEX zone; activate parking brakes and/or leveling feet before start-up, and protect electrical lines below the unit from condensate.

What maintenance and consumables are required, and what is not included in base delivery?

Refrigerant-circuit work is restricted to approved refrigeration contractors; shut off cooling water even overnight. The base delivery includes the cable but no plug, and no heat-transfer fluid: charge the loop with at least 3.8 l of water plus glycine or ethylene glycol, avoiding acetone and polyglycols.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P025w OLÉ Technical Data
Datasheet ·81,2 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF