Peter Huber Kältemaschinenbau Unichiller P012w OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P012w OLÉ

Peter Huber Kältemaschinenbau Unichiller P012w OLÉ — Recirculating chillers.

The Unichiller P012w OLÉ is a water-cooled recirculating chiller with a plastic pump (type B) and OLÉ controller, rated 1 kW cooling at 0 °C over a -20…40 °C range. Its 'P' designation targets high-pressure-drop process loops, distinguishing it from the 015 siblings. It serves closed external circuits requiring stable temperature control.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller P012w OLÉ Current —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 56 kg
Electrical, Power & Drive Specifications
Current consumption 7 A (max.)
Fuse rating 16 A
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 1 kW (at 0 °C)
Cooling water connection G1/2 male
Cooling water consumption 48 l/h (at 15°C, flow -10°C)
at 15°C, flow 0°C: 57 l/h · at 15°C, flow 15°C: 60 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Thermal behavior and media

Control, installation and operation

Integration & Operating Notes

Process Limits
Closed-loop external circuit only; no open bath use

The manual states the unit is designed for externally closed applications. Designing an open tank or atmospheric circuit around this chiller violates the intended hydraulic configuration and may cause pump or temperature-control problems.

Unichiller Operation Manual, Function Description, page 34
Cooling & Media
Cooling water must stay within 1–6 bar differential

The cooling water circuit requires a minimum differential pressure of 1 bar and tolerates a maximum pressure of 6 bar. Verify the site supply before connection; insufficient differential pressure undermines capacity, while exceeding 6 bar risks the water circuit.

Unichiller P012w OLÉ Technical Data Sheet, page 1
Cooling & Media
Cooling water intake limited to 5–20 °C; insulate if condensing

The unit is designed for cooling water intake between 5 °C and 20 °C. If the cooling water temperature falls below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensate formation.

Unichiller P012w OLÉ Technical Data Sheet, page 2
Electrical
Avoid -5% voltage combined with +2% frequency

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and the combination of -5% voltage with +2% frequency is explicitly not allowed. Check the site supply envelope before commissioning to stay within the permitted window.

Unichiller P012w OLÉ Technical Data Sheet, page 2
Electrical
Specify country-specific plug at order time

Single/two-phase devices are supplied with a power cable and a country-specific plug that must be specified when ordering. Confirm the site outlet type before placing the order to avoid a mismatch on delivery.

Unichiller P012w OLÉ Technical Data Sheet, page 2
Mounting
Keep 50–200 cm clearance per side for maintenance

A wall clearance of 50 to 200 cm per side is required on free-standing models for maintenance access. Plan the installation footprint accordingly; also protect electrical lines directly below the unit against liquid ingress from condensation.

Unichiller Operation Manual, Installation, page 25 and page 28
Mounting
Indoor use only, at least 300 lx, up to 2000 m altitude

The unit may only be used indoors with an illuminance of at least 300 lx and at altitudes up to 2000 m. Ambient temperature must remain within 5…40 °C, and the IP20 rating means the location must be dry and free of excessive dust.

Unichiller Operation Manual, Installation, page 25; Technical Data Sheet, page 2
Process Limits
Not permitted inside an ATEX zone

The unit is not explosion-protected and must not be installed or started up within an ATEX zone. Additionally, the R-290 refrigerant charge of 0.09 kg must be checked against the room size to avoid exceeding the refrigerant limit per m³ of ambient air.

Unichiller Operation Manual, page 13 and page 15
Control & I/O
Configure power-failure response before unattended operation

The OLÉ controller includes an autostart function for power failure, and the power-failure response can be set to OFF/Standby, ON, or Power Failure Auto. Decide the required behavior for the process before commissioning, since automatic restart may be unacceptable for some loads.

Unichiller P012w OLÉ Technical Data Sheet, page 1; Unichiller Operation Manual, page 19
Process Limits
Use Process Safety mode for exothermic reactions

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.

Unichiller Operation Manual, page 18
Maintenance
Refrigerant circuit work only by approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Plan service access and contractor qualification accordingly; the unit uses flammable R-290 refrigerant.

Unichiller Operation Manual, page 17
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply must be shut off even for shorter downtimes such as overnight to prevent water damage and corrosion. Include this step in the operating procedure and consider an isolation valve in the cooling water line.

Unichiller Operation Manual, page 28
Mounting
Activate leveling feet and parking brakes before start-up

Before the unit is put into operation, the parking brakes must be activated at the casters (if any) and/or the leveling feet must be unscrewed/activated. This prevents movement and crushing injuries during operation.

Unichiller Operation Manual, page 31

Selection & Integration Q&A

When should I choose the P012w OLÉ instead of a Unichiller 015 variant?

Choose the P012w OLÉ when the process loop has high pressure drop, since the 'P' in the model name marks units particularly suitable for such applications. The 015 siblings are listed separately; select them when their capacity and configuration better match the duty without the high-pressure-drop requirement.

What cooling water supply and quality does the P012w OLÉ require from adjacent systems?

Supply cooling water at 5–20 °C with 1 bar minimum differential pressure and 6 bar maximum. The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. Connections are G1/2 male; consumption is 48–60 l/h at 15 °C inlet depending on flow temperature.

What installation environment and duty-cycle limits apply to this chiller?

Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, with 50–200 cm clearance per side for maintenance. IP20 requires a dry location. The unit is not ATEX-rated and must not be placed in an explosion-protected zone; check the 0.09 kg R-290 charge against room volume.

What maintenance and accessories are required beyond the base delivery?

The base unit includes a power cable with country-specific plug only if specified at order. Refrigerant circuit work must be done by approved refrigeration contractors. The optional factory-fitted Pt100 sensor connection (#10519) for external process temperature display cannot be retrofitted, so order it with the unit if needed.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P012w OLÉ — Technical Data Sheet
Datasheet ·97,2 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF