Peter Huber Kältemaschinenbau Unichiller 020T-H
Peter Huber Kältemaschinenbau Unichiller 020T-H — Recirculating chillers.
The Unichiller 020T-H is an air-cooled recirculating chiller for externally closed circuits, operating from -20 to 100 °C on a 208 V 2~ 60 Hz supply. Within the Unichiller series it is the 2 kW-class model with Pilot ONE control and fixed-speed pump B. It serves as the cooling source for closed process loops requiring DIN 12876 overtemperature protection.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 020T-H Current | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Expansion volume | 2 l |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 141 kg |
| Current consumption | 14 A (max) |
| Power supply | 208V 2~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The 020T-H is a free-standing, air-cooled chiller rated IP20, weighing 141 kg, with a 2 l expansion volume and a minimum filling capacity of 2.5 l. Unlike the sibling Unichiller 015 variants (015, 015-H, 015-H OLÉ, 015 OLÉ), this model carries the 020 designation and the -H suffix; the manual notes that models with 'P' in the name are intended for high-pressure-drop applications, which this model is not. The unit is designed exclusively for externally closed applications, so the user circuit must be closed.
Thermal and hydraulic behavior
Cooling capacity is rated at 20 °C room temperature and falls with rising ambient temperature; published points give 2 kW at 0 °C and 0.8 kW at -20 °C, so low-temperature duty carries reduced capacity. The fixed-speed pump B delivers 29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar, so external circuit pressure drop must be checked against this curve. Pump connections are G3/4 male. The temperature range is -20 to 100 °C with adjustable overtemperature protection to DIN 12876; Process Safety mode releases maximum cooling capacity when the OT trigger is reached instead of switching off all poles.
Control, installation and operation
The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, a Pt100 external sensor connection, and a configurable power-failure response (OFF/Standby, ON, Power Failure Auto). The unit requires 208 V 2~ 60 Hz, 14 A maximum current and 2x16 A fusing; three-phase devices below 63 A are delivered with cable but without a plug. Voltage tolerance is ±5% only with ±2% frequency tolerance, and -5% voltage with +2% frequency is not allowed. Installation requires 50–200 cm wall clearance per side, indoor use at ≥300 lx and up to 2000 m altitude, ambient 5–40 °C, and no ATEX zone. Leveling feet or parking brakes must be set before start-up, and cooling water (where applicable) must be shut off even overnight.
Integration & Operating Notes
The unit draws up to 14 A and requires a 208 V two-phase 60 Hz supply protected at 2x16 A. Three-phase devices below 63 A ship with cable but no plug, so a suitable plug must be provided on site. Verify that voltage and frequency tolerances are met simultaneously; -5% voltage with +2% frequency is explicitly not allowed.
The chiller is intended only for externally closed applications. The fixed-speed pump B delivers 29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar, so the pressure drop of hoses, fittings and the process load must be checked against this curve. Pump connections are G3/4 male; mating couplings must match this thread and be counterheld during tightening.
Free-standing installation requires 50 to 200 cm clearance on either side for service access. The unit must be indoors at ≥300 lx and up to 2000 m altitude, with ambient temperature between 5 and 40 °C. It must not be installed or started inside an ATEX zone because it is not explosion-protected. Leveling feet must be activated and parking brakes applied before start-up.
Published cooling capacity is rated at 20 °C room temperature and may drop as ambient rises. At the cold end, capacity falls from 2 kW at 0 °C to 0.8 kW at -20 °C, so low-temperature duty must be sized accordingly. Minimum filling capacity is 2.5 l with 2 l expansion volume; the refrigerant is R-449A (GWP 1397), and room size versus charge must be checked at installation.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto, which determines whether the process restarts automatically after an outage. Adjustable overtemperature protection to DIN 12876 must be set for the application; Process Safety mode releases maximum cooling capacity at the OT trigger instead of switching off all poles, which matters for exothermic processes.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit is classified to DIN 12876 with identification depending on whether the thermal fluid is combustible, so the rating on the data sheet appendix determines the required safety class (NFL/FL) and protection devices for the chosen fluid.
Selection & Integration Q&A
Choose the 020T-H when you need the 2 kW-class cooling capacity at 0 °C and the -20 to 100 °C range with Pilot ONE control. The 015 siblings are lower-capacity variants; the -H and OLÉ suffixes denote different configurations. If your process has high pressure drop, note that only models with 'P' in the name are specifically suited for that, so this model is not the high-pressure-drop choice.
The external circuit must be closed, with hoses and couplings matching the G3/4 male pump connections and counterheld during tightening. Check the loop pressure drop against the pump curve (29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar). Provide at least 2.5 l filling capacity with 2 l expansion volume, and a Pt100 sensor if external temperature control is used.
Install indoors only, at ≥300 lx and up to 2000 m altitude, with ambient between 5 and 40 °C and 50–200 cm wall clearance per side. The unit is IP20 and not explosion-protected, so no ATEX zone. Activate leveling feet or parking brakes before start-up. Cooling capacity is rated at 20 °C room temperature and derates as ambient rises; at -20 °C it is 0.8 kW.
The unit ships with cable but without a plug for three-phase devices below 63 A, so a suitable 208 V 2~ 60 Hz plug must be provided. Refrigerant circuit work requires approved refrigeration/air-conditioning contractors. The DIN 12876 safety class (NFL/FL) depends on whether the thermal fluid is combustible, so select the fluid and protection devices accordingly. Shut off cooling water even for overnight downtimes.