Peter Huber Kältemaschinenbau Unichiller 020T-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 020T-H

Peter Huber Kältemaschinenbau Unichiller 020T-H — Recirculating chillers.

The Unichiller 020T-H is an air-cooled recirculating chiller for externally closed circuits, operating from -20 to 100 °C on a 208 V 2~ 60 Hz supply. Within the Unichiller series it is the 2 kW-class model with Pilot ONE control and fixed-speed pump B. It serves as the cooling source for closed process loops requiring DIN 12876 overtemperature protection.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 020T-H Current —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Expansion volume 2 l
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 141 kg
Electrical, Power & Drive Specifications
Current consumption 14 A (max)
Power supply 208V 2~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The 020T-H is a free-standing, air-cooled chiller rated IP20, weighing 141 kg, with a 2 l expansion volume and a minimum filling capacity of 2.5 l. Unlike the sibling Unichiller 015 variants (015, 015-H, 015-H OLÉ, 015 OLÉ), this model carries the 020 designation and the -H suffix; the manual notes that models with 'P' in the name are intended for high-pressure-drop applications, which this model is not. The unit is designed exclusively for externally closed applications, so the user circuit must be closed.

Thermal and hydraulic behavior

Cooling capacity is rated at 20 °C room temperature and falls with rising ambient temperature; published points give 2 kW at 0 °C and 0.8 kW at -20 °C, so low-temperature duty carries reduced capacity. The fixed-speed pump B delivers 29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar, so external circuit pressure drop must be checked against this curve. Pump connections are G3/4 male. The temperature range is -20 to 100 °C with adjustable overtemperature protection to DIN 12876; Process Safety mode releases maximum cooling capacity when the OT trigger is reached instead of switching off all poles.

Control, installation and operation

The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, a Pt100 external sensor connection, and a configurable power-failure response (OFF/Standby, ON, Power Failure Auto). The unit requires 208 V 2~ 60 Hz, 14 A maximum current and 2x16 A fusing; three-phase devices below 63 A are delivered with cable but without a plug. Voltage tolerance is ±5% only with ±2% frequency tolerance, and -5% voltage with +2% frequency is not allowed. Installation requires 50–200 cm wall clearance per side, indoor use at ≥300 lx and up to 2000 m altitude, ambient 5–40 °C, and no ATEX zone. Leveling feet or parking brakes must be set before start-up, and cooling water (where applicable) must be shut off even overnight.

Integration & Operating Notes

Electrical
Supply must be 208 V 2~ 60 Hz with 2x16 A fusing

The unit draws up to 14 A and requires a 208 V two-phase 60 Hz supply protected at 2x16 A. Three-phase devices below 63 A ship with cable but no plug, so a suitable plug must be provided on site. Verify that voltage and frequency tolerances are met simultaneously; -5% voltage with +2% frequency is explicitly not allowed.

Unichiller 020T-H Technical Data Sheet, Specifications
Process Limits
External circuit must be closed and matched to pump curve

The chiller is intended only for externally closed applications. The fixed-speed pump B delivers 29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar, so the pressure drop of hoses, fittings and the process load must be checked against this curve. Pump connections are G3/4 male; mating couplings must match this thread and be counterheld during tightening.

Unichiller 020T-H Technical Data Sheet, Specifications; Unichiller Operation Manual, Function Description
Mounting
Allow 50–200 cm wall clearance per side for maintenance

Free-standing installation requires 50 to 200 cm clearance on either side for service access. The unit must be indoors at ≥300 lx and up to 2000 m altitude, with ambient temperature between 5 and 40 °C. It must not be installed or started inside an ATEX zone because it is not explosion-protected. Leveling feet must be activated and parking brakes applied before start-up.

Unichiller Operation Manual, Installation and Commissioning
Cooling & Media
Cooling capacity derates with ambient and at low temperatures

Published cooling capacity is rated at 20 °C room temperature and may drop as ambient rises. At the cold end, capacity falls from 2 kW at 0 °C to 0.8 kW at -20 °C, so low-temperature duty must be sized accordingly. Minimum filling capacity is 2.5 l with 2 l expansion volume; the refrigerant is R-449A (GWP 1397), and room size versus charge must be checked at installation.

Unichiller 020T-H Technical Data Sheet, Specifications; Unichiller Operation Manual, Installation
Control & I/O
Configure power-failure response and OT protection before run

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto, which determines whether the process restarts automatically after an outage. Adjustable overtemperature protection to DIN 12876 must be set for the application; Process Safety mode releases maximum cooling capacity at the OT trigger instead of switching off all poles, which matters for exothermic processes.

Unichiller Operation Manual, Normal Operation and Safety
Maintenance
Refrigerant circuit work only by approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit is classified to DIN 12876 with identification depending on whether the thermal fluid is combustible, so the rating on the data sheet appendix determines the required safety class (NFL/FL) and protection devices for the chosen fluid.

Unichiller Operation Manual, Maintenance and Compliance

Selection & Integration Q&A

When should I choose the Unichiller 020T-H rather than a sibling 015 variant?

Choose the 020T-H when you need the 2 kW-class cooling capacity at 0 °C and the -20 to 100 °C range with Pilot ONE control. The 015 siblings are lower-capacity variants; the -H and OLÉ suffixes denote different configurations. If your process has high pressure drop, note that only models with 'P' in the name are specifically suited for that, so this model is not the high-pressure-drop choice.

What must I provide on the process side to connect this chiller?

The external circuit must be closed, with hoses and couplings matching the G3/4 male pump connections and counterheld during tightening. Check the loop pressure drop against the pump curve (29 l/min at 0.12 bar down to 6.5 l/min at 3.0 bar). Provide at least 2.5 l filling capacity with 2 l expansion volume, and a Pt100 sensor if external temperature control is used.

What are the installation environment and duty-cycle limits for the 020T-H?

Install indoors only, at ≥300 lx and up to 2000 m altitude, with ambient between 5 and 40 °C and 50–200 cm wall clearance per side. The unit is IP20 and not explosion-protected, so no ATEX zone. Activate leveling feet or parking brakes before start-up. Cooling capacity is rated at 20 °C room temperature and derates as ambient rises; at -20 °C it is 0.8 kW.

What maintenance and accessories are required beyond the base delivery?

The unit ships with cable but without a plug for three-phase devices below 63 A, so a suitable 208 V 2~ 60 Hz plug must be provided. Refrigerant circuit work requires approved refrigeration/air-conditioning contractors. The DIN 12876 safety class (NFL/FL) depends on whether the thermal fluid is combustible, so select the fluid and protection devices accordingly. Shut off cooling water even for overnight downtimes.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 020T-H Technical Data Sheet
Datasheet ·97,6 КБ ·2 pp.
View PDF