Peter Huber Kältemaschinenbau Unichiller 022w-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 022w-H

Peter Huber Kältemaschinenbau Unichiller 022w-H — Recirculating chillers.

The Unichiller 022w-H is a water-cooled recirculating chiller with a plastic pump, rated for externally closed circuits from -10 to 100 °C and up to 2.2 kW cooling at 15 °C. It is the higher-capacity 'w' variant in the Unichiller series, distinguished by water cooling and a Pilot ONE controller. It serves as a central cooling source for laboratory and pilot-scale processes requiring stable temperature control.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 022w-H Current —Pilot ONEIII / FL-10–100——
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Temperature range -10...100 °C
Dimensions, Weight & Mechanical Design
Weight 61 kg
Interfaces, Connections & Control
Controller Pilot ONE
Operating Conditions, Environment & Protection
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Performance and media behavior

Installation, control and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow maintenance access to the refrigeration circuit and pump. Insufficient clearance blocks service work and may void warranty; plan the footprint accordingly.

Unichiller Operation Manual, Section 'Installation'
Process Limits
Cooling water must stay within 5–20 °C inlet temperature

The chiller is designed for cooling water intake between 5 °C and 20 °C. Higher water temperatures reduce cooling capacity and may increase flow rate, so size the supply system for the actual site water temperature and insulate pipes if condensation is possible.

Unichiller 022w-H Datasheet, Specifications
Electrical
Voltage and frequency tolerances must be met simultaneously

Supply voltage may deviate ±5% only if frequency deviation is within ±2%, and combinations such as -5% voltage with +2% frequency are not permitted. Verify site power quality before commissioning to avoid controller faults or compressor damage.

Unichiller 022w-H Datasheet, Specifications
Control & I/O
Configure power-failure response to match process restart needs

The Pilot ONE controller allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For unattended processes, choose the mode that prevents unexpected restart or ensures safe shutdown; document the setting in the control narrative.

Unichiller Operation Manual, Section 'Normal Operation'
Safety
Use Process Safety mode for exothermic reactions

In Process Safety mode, the controller releases maximum cooling capacity when the overtemperature trigger value is reached, instead of switching off all poles. This prevents runaway temperatures in exothermic processes; configure the OT trigger according to the application's thermal limits.

Unichiller Operation Manual, Section 'Safety'
Maintenance
Refrigerant circuit work requires certified contractors

Any work on the refrigerant circuit must be performed only by approved refrigeration/air-conditioning system contractors. Plan service contracts accordingly; unauthorized intervention may void certification and poses environmental and safety risks.

Unichiller Operation Manual, Section 'Maintenance'
Operation
Shut off cooling water during even short downtimes

Close the cooling water supply to the unit overnight and during other short downtimes to prevent water damage and corrosion. This is especially important in facilities where water pressure may fluctuate or where condensate can form.

Unichiller Operation Manual, Section 'Operation'
Installation
Do not install in ATEX zones or outdoors

The unit is not explosion-protected and must not be installed or started up inside an ATEX zone. It is for indoor use only, at illuminance ≥300 lx and altitudes up to 2000 m. Verify the site classification before delivery.

Unichiller Operation Manual, Section 'Installation'

Selection & Integration Q&A

When should I choose the Unichiller 022w-H over the 015 series siblings?

Choose the 022w-H when you need water cooling and higher capacity: 2.2 kW at 15 °C versus the 015 series' lower capacity. The 015 models suit lower heat loads.

What are the requirements for the cooling water supply and adjacent piping?

Cooling water inlet must be 5–20 °C; higher temperatures reduce capacity and may increase flow. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so use compatible water quality and insulate pipes if condensation is possible.

What installation and duty-cycle limits apply from the manual?

Install indoors only (illuminance ≥300 lx, altitude ≤2000 m), not in ATEX zones. Maintain 50–200 cm side clearance for maintenance. Shut off cooling water during short downtimes. Leveling feet or parking brakes must be engaged before operation.

What maintenance is required and what is not included in the base delivery?

Refrigerant circuit work must be by certified contractors. Base delivery includes power cable and country-specific plug for single/two-phase units (specify at order); three-phase <63A units come with cable but no plug. Heat transfer fluid and freeze-protection additives are not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 022w-H Recirculating Chiller Datasheet
Datasheet ·18,5 КБ ·2 pp.
View PDF