Peter Huber Kältemaschinenbau Unichiller P012w OLÉ
Peter Huber Kältemaschinenbau Unichiller P012w OLÉ — Recirculating chillers.
The Unichiller P012w OLÉ is a water-cooled recirculating chiller with a plastic pump (type B) and OLÉ controller, rated 1 kW cooling at 0 °C over a -20…40 °C range. Its 'P' designation targets high-pressure-drop process loops, distinguishing it from the 015 siblings. It serves closed external circuits requiring stable temperature control.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P012w OLÉ Current | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Full specifications
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| Temperature range | -20...40 °C |
| Weight | 56 kg |
| Current consumption | 7 A (max.) |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 1 kW (at 0 °C) |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 48 l/h (at 15°C, flow -10°C) at 15°C, flow 0°C: 57 l/h · at 15°C, flow 15°C: 60 l/h |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit using R-290 (propane, A3, H220) with a 0.09 kg charge; cooling water connections are G1/2 male, pump connections G3/4 AG male.
- Plastic pump, type B, non-adjustable speed; safety class I / NFL; IP20 protection; 56 kg.
- Within the Unichiller series, the 'P' in the model name marks this unit as particularly suitable for applications requiring high pressure drops, unlike the 015 siblings listed.
Thermal behavior and media
- Temperature range -20…40 °C; cooling capacity 1 kW at 0 °C, valid only at room temperature 20 °C, cooling water inlet 15 °C and 1 bar differential pressure.
- Cooling water consumption at 15 °C inlet: 60 l/h at 15 °C flow, 57 l/h at 0 °C flow, 48 l/h at -10 °C flow. Warmer cooling water reduces cooling power and may require higher flow.
- Cooling water intake designed for 5…20 °C; if below the condensation point, internal cooling water pipes must be insulated. The plastic pump is not resistant to acetone or polyglycols; water with glysantine or ethylene glycol is recommended for freeze protection.
Control, installation and operation
- OLÉ controller with OLED display, 0.1 K display resolution, USB (Device) and RS232 interfaces; autostart after power failure is included.
- Power supply 220-240 V 1~/2~ 50/60 Hz, max current 7 A, fuse 16 A; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and -5% voltage with +2% frequency is not allowed. Country-specific plug must be specified at order.
- Intended only for externally closed applications; must not be installed in an ATEX zone; indoor use only, illuminance at least 300 lx, altitude up to 2000 m; ambient 5…40 °C; wall clearance 50–200 cm per side for maintenance.
Integration & Operating Notes
The manual states the unit is designed for externally closed applications. Designing an open tank or atmospheric circuit around this chiller violates the intended hydraulic configuration and may cause pump or temperature-control problems.
The cooling water circuit requires a minimum differential pressure of 1 bar and tolerates a maximum pressure of 6 bar. Verify the site supply before connection; insufficient differential pressure undermines capacity, while exceeding 6 bar risks the water circuit.
The unit is designed for cooling water intake between 5 °C and 20 °C. If the cooling water temperature falls below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensate formation.
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and the combination of -5% voltage with +2% frequency is explicitly not allowed. Check the site supply envelope before commissioning to stay within the permitted window.
Single/two-phase devices are supplied with a power cable and a country-specific plug that must be specified when ordering. Confirm the site outlet type before placing the order to avoid a mismatch on delivery.
A wall clearance of 50 to 200 cm per side is required on free-standing models for maintenance access. Plan the installation footprint accordingly; also protect electrical lines directly below the unit against liquid ingress from condensation.
The unit may only be used indoors with an illuminance of at least 300 lx and at altitudes up to 2000 m. Ambient temperature must remain within 5…40 °C, and the IP20 rating means the location must be dry and free of excessive dust.
The unit is not explosion-protected and must not be installed or started up within an ATEX zone. Additionally, the R-290 refrigerant charge of 0.09 kg must be checked against the room size to avoid exceeding the refrigerant limit per m³ of ambient air.
The OLÉ controller includes an autostart function for power failure, and the power-failure response can be set to OFF/Standby, ON, or Power Failure Auto. Decide the required behavior for the process before commissioning, since automatic restart may be unacceptable for some loads.
In Process Safety mode the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Plan service access and contractor qualification accordingly; the unit uses flammable R-290 refrigerant.
The cooling water supply must be shut off even for shorter downtimes such as overnight to prevent water damage and corrosion. Include this step in the operating procedure and consider an isolation valve in the cooling water line.
Before the unit is put into operation, the parking brakes must be activated at the casters (if any) and/or the leveling feet must be unscrewed/activated. This prevents movement and crushing injuries during operation.
Selection & Integration Q&A
Choose the P012w OLÉ when the process loop has high pressure drop, since the 'P' in the model name marks units particularly suitable for such applications. The 015 siblings are listed separately; select them when their capacity and configuration better match the duty without the high-pressure-drop requirement.
Supply cooling water at 5–20 °C with 1 bar minimum differential pressure and 6 bar maximum. The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. Connections are G1/2 male; consumption is 48–60 l/h at 15 °C inlet depending on flow temperature.
Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, with 50–200 cm clearance per side for maintenance. IP20 requires a dry location. The unit is not ATEX-rated and must not be placed in an explosion-protected zone; check the 0.09 kg R-290 charge against room volume.
The base unit includes a power cable with country-specific plug only if specified at order. Refrigerant circuit work must be done by approved refrigeration contractors. The optional factory-fitted Pt100 sensor connection (#10519) for external process temperature display cannot be retrofitted, so order it with the unit if needed.