Peter Huber Kältemaschinenbau Unichiller 160T
Peter Huber Kältemaschinenbau Unichiller 160T — Recirculating chillers.
The Unichiller 160T is a free-standing, air-cooled recirculating chiller with a non-variable C3 pressure pump and Pilot ONE controller, rated -10 to 40 °C. Within the Unichiller series it is the 160-size, 400 V three-phase modification, distinguished from the 110T siblings by capacity rather than by a 'P' high-pressure-drop or water-cooled variant. It serves externally closed industrial process loops requiring up to 16 kW of cooling at 15 °C.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 160T Current | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | C3 |
| External sensor connection | Pt100 |
| Temperature range | -10...40 °C |
| Weight | 433 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Free-standing cabinet with casters and leveling feet; 433 kg; IP20 enclosure for dry indoor installation.
- Refrigerant R-449A (A1, H280; GWP 1397); EMC Class A Group 1, intended for industrial environments.
- Pump: C3 pressure pump, speed not variable, G1 1/4 AG male connections; 99 l/min at zero head, 5.9 bar maximum delivery pressure.
- Siblings in the same series are the 110T, 110T-H, 110Tw and 110Tw-H; the 160T is the larger-capacity, three-phase 400 V/50 Hz unit. Models with 'P' in the name are the high-pressure-drop variants; the 160T carries no 'P'.
Behavior under load and media
- Cooling capacity is strongly temperature-dependent: 16 kW at 15 °C, 8.8 kW at 0 °C and 4 kW at -10 °C. Sizing must use the actual process temperature, not the 15 °C figure.
- Rated output data are valid at 20 °C room temperature; above that, cooling capacity may drop. Ambient range is 5–40 °C.
- Hydraulic circuit: minimum filling capacity 14 l, expansion volume 39 l. The external loop volume must be checked against the expansion volume for correct expansion-tank operation.
- Pump curve: flow falls from 99 l/min at zero head to 39 l/min at 5.0 bar; system pressure drop must be checked against this curve.
Installation, control and operation
- Supply: 400 V 3~ 50 Hz; voltage tolerance ±5% and frequency ±2%, not to be combined in opposite directions. Three-phase devices below 63 A are delivered with cable but without a plug.
- Controller: Pilot ONE with Ethernet, USB host and device, and RS232; external Pt100 sensor connection. Power-failure response configurable as OFF/Standby, ON or Power Failure Auto.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, instead of switching off all poles.
- Installation: indoors only, illuminance at least 300 lx, altitude up to 2000 m; wall clearance 50–200 cm per side for maintenance; not permitted in ATEX zones. Refrigerant charge versus room size must be checked.
- Cooling water supply (where applicable) must be shut off even for overnight downtimes; electrical lines below a water-cooled unit must be protected against condensate.
Integration & Operating Notes
The manual restricts the unit to externally closed applications, so the hydraulic circuit must be designed as a sealed loop with an expansion volume of 39 l and a minimum fill of 14 l. Open-tank or atmospheric processes are outside the intended use and invalidate the thermal design assumptions.
Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance. The unit must also stand indoors at illuminance of at least 300 lx and at altitudes up to 2000 m; installation inside an ATEX zone is prohibited because the unit is not explosion-protected.
Cooling capacity falls from 16 kW at 15 °C to 8.8 kW at 0 °C and 4 kW at -10 °C, and rated data assume 20 °C room temperature. Above 20 °C ambient the capacity may drop further. Selection must therefore use the lowest expected process temperature and the real ambient, not the headline 15 °C figure.
The C3 pump is not speed-adjustable and delivers 99 l/min at zero head but only 39 l/min at 5.0 bar. The external circuit pressure drop must be calculated against this curve; a high-drop loop will reduce flow below the process requirement, and the 'P' high-pressure-drop variant is the appropriate series alternative in that case.
The unit uses R-449A (A1, H280; GWP 1397). Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Leak detection and refrigerant handling procedures apply, and the refrigerant charge versus room size must be checked at installation.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles. The chosen mode must be agreed with the process safety concept before commissioning.
The four-year warranty requires registration. Commissioning paperwork must be completed and submitted so that coverage is preserved; otherwise the warranty period may not apply to the delivered unit.
Selection & Integration Q&A
Pick the 160T when the process needs the larger 160-size capacity at 400 V three-phase and a standard-pressure-drop loop. Choose a 110T sibling for lower capacity; choose a 'P' model if the external circuit has high pressure drop, since the 160T's fixed-speed pump falls to 39 l/min at 5.0 bar.
The pump connection is G1 1/4 male, so mating hoses and fittings must match that thread and be counterheld at the maximum tightening torque. Electrically, the site must supply 400 V 3~ 50 Hz within ±5% voltage and ±2% frequency and provide a plug, since three-phase units below 63 A ship with cable but no plug.
Install indoors only, at 5–40 °C ambient, illuminance at least 300 lx, altitude up to 2000 m, with 50–200 cm clearance per side. It is IP20 and not ATEX-rated. Cooling capacity is rated at 20 °C room temperature and may drop above that; shut off cooling water even for overnight downtimes.
Refrigerant-circuit work on the R-449A system must be done by approved refrigeration contractors. The unit ships with cable but without a plug for three-phase supply below 63 A, and the four-year warranty requires registration. External hoses, fittings and the mating plug are customer-supplied.