Peter Huber Kältemaschinenbau Unichiller 600Tw
Peter Huber Kältemaschinenbau Unichiller 600Tw — Recirculating chillers.
The Unichiller 600Tw is a water-cooled recirculating chiller rated at 60 kW with R-449A refrigerant, operating from -20 to 40 °C. It is the large-capacity member of the Unichiller series, distinguished by its 400 V three-phase supply and 45 A draw. It serves externally closed process loops requiring high cooling capacity and a stable temperature setpoint.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 600Tw Current | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 7 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 598 kg |
| Current consumption | 45 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1 1/4 male |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The 600Tw is a water-cooled, CFC/HCFC-free chiller using R-449A (A1, H280) with a GWP of 1397 and a CO2 equivalent of 8.4 t. It is built for externally closed applications only.
- Within the Unichiller series, the 600Tw is the high-capacity three-phase variant; sibling models such as the 110T and 110Tw are smaller units with noise levels of 74 dB(A) and 65 dB(A) respectively. The 600Tw is water-cooled and requires a facility cooling-water circuit.
- The unit uses the Pilot ONE controller and a fixed-speed D3 pump (not speed-adjustable), with G1 1/4 AG male pump connections and G1 1/4 male cooling-water connections.
Behavior under load and media
- Cooling capacity is rated at 60 kW at 15 °C cooling-water intake; capacity drops and cooling-water flow demand rises as intake temperature increases. The design window for cooling-water intake is 5 to 20 °C.
- The pump delivers a maximum of 234 l/min and 197 l/min at 1.3 bar; pressure-dependent flow data must be used to match the external circuit's pressure drop.
- The temperature range is -20 to 40 °C. The unit is classified to DIN 12876 with safety class I / NFL, and the identification depends on whether the thermal fluid is combustible.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles — relevant for exothermic processes.
Installation, connection and control
- Electrical supply is 400 V 3~ 50 Hz with a maximum current consumption of 45 A; a 3x50 A fuse is required. The unit is supplied with cable but without a plug. Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not allowed.
- Cooling water must have a differential pressure of at least 1.5 bar and a maximum supply pressure of 6 bar. Pipes must be insulated if water temperature can fall below the condensation point.
- The unit is IP20 and must be operated indoors at 5 to 40 °C ambient, at an illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance.
- Interfaces include Ethernet, USB (Host and Device) and RS232; an external Pt100 sensor connection is provided. The power-failure response is configurable via Pilot ONE as OFF/Standby, ON, or Power Failure Auto.
- Minimum filling capacity is 12.7 l and expansion volume is 7 l. The unit weighs 598 kg.
Integration & Operating Notes
The unit draws up to 45 A at 400 V 3~ 50 Hz and is delivered with cable but without a plug. The installer must provide a 3x50 A protection device and a matching plug; voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not permitted.
The chiller requires cooling water with a differential pressure of at least 1.5 bar and a maximum supply pressure of 6 bar. Intake temperature must be between 5 and 20 °C; capacity drops as water temperature rises. Pipes must be insulated if the water temperature can fall below the condensation point.
A wall clearance of 50 to 200 cm per side is required for maintenance. Before switching on, parking brakes must be activated at the casters and/or leveling feet unscrewed/activated to prevent movement. The unit must be installed indoors at 5–40 °C ambient and at least 300 lx illuminance.
The Pilot ONE allows the power-failure response to be set as OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles; this must be selected according to the process risk.
Work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A with a GWP of 1397 and a CO2 equivalent of 8.4 t, so leak checks and environmental reporting obligations apply. Cooling water supply must be shut off even for short downtimes such as overnight.
The unit is designed only for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. The refrigerant charge and room size must be checked at installation to avoid exceeding the refrigerant limit per m³ of ambient air.
Selection & Integration Q&A
Choose the 600Tw when you need 60 kW cooling capacity at 15 °C water and a three-phase 400 V supply with 45 A draw. The 110Tw is smaller; the 600Tw is water-cooled and requires a facility cooling-water circuit with ≥1.5 bar differential pressure.
Cooling water: 5–20 °C intake, ≥1.5 bar differential, max 6 bar supply, G1 1/4 male connections. Electrical: 400 V 3~ 50 Hz, 45 A max, 3x50 A fuse, cable supplied without plug. Voltage/frequency tolerances ±5%/±2%, but -5% voltage with +2% frequency is not allowed.
Install indoors only, at 5–40 °C ambient, ≥300 lx illuminance, up to 2000 m altitude. Keep 50–200 cm wall clearance per side. Activate parking brakes or leveling feet before operation. Do not install in an ATEX zone. Protect electrical lines below the unit from condensation.
Refrigerant circuit work must be done by approved contractors; R-449A has GWP 1397 and CO2e 8.4 t. Shut off cooling water even overnight. The unit is delivered with cable but without a plug; the 3x50 A fuse and plug are site-provided. Minimum filling capacity is 12.7 l; expansion volume 7 l.