Peter Huber Kältemaschinenbau Unichiller P230-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P230-H

Peter Huber Kältemaschinenbau Unichiller P230-H — Recirculating chillers.

The Unichiller P230-H is an air-cooled, externally closed recirculating chiller with a fixed-speed E2 pressure pump and G1 1/4 male connections, rated -20 to 100 °C. Its 'P' designation targets high-pressure-drop process loops, distinguishing it from the 110T/110Tw siblings. It serves as a central cooling source for closed process circuits requiring up to 23 kW at 20 °C.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller P230-H Current E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 48 l
Heating capacity 2 kW
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load

Installation, control and operation

Integration & Operating Notes

Electrical
Supply tolerance pairing is restricted

The compressor and pump must not be operated with -5% voltage combined with +2% frequency; verify site supply quality before commissioning, because this combination is explicitly not allowed and can stress the refrigeration circuit.

Unichiller P230-H Datasheet, page 2
Electrical
Cable supplied, plug and breaker are site scope

Three-phase devices drawing less than 63 A arrive with a cable but no plug, and external branch circuit protection according to UL 489 must be provided by the installer; plan the panel and receptacle accordingly.

Unichiller P230-H Datasheet, page 2
Mounting
Side clearance for maintenance and airflow

Free-standing installation requires 50 to 200 cm wall clearance on either side for maintenance, and the air-cooled condenser needs unobstructed airflow; insufficient clearance reduces cooling performance and risks overheating.

Unichiller Operation Manual, page 25
Mounting
Indoor, non-ATEX site only

The unit is not explosion-protected and must not be installed or started inside an ATEX zone; it is for indoor use at illuminance of at least 300 lx and up to 2000 m altitude, with IP20 requiring protection from water and dust.

Unichiller Operation Manual, page 13 and page 25
Process Limits
Closed loop with adequate fill volume

The chiller is designed only for externally closed applications; the loop must provide at least 18 l filling capacity and account for the 48 l expansion volume, and the G1 1/4 male pump connections must be counterheld at the stated maximum torque.

Unichiller P230-H Datasheet, page 1; Operation Manual, page 28
Control & I/O
Configure power-failure and OT response before run

The Pilot ONE allows OFF/Standby, ON or Power Failure Auto after mains loss, and Process Safety mode releases maximum cooling at the overtemperature trigger instead of switching off; select the behavior that matches the exothermic risk of the process.

Unichiller Operation Manual, page 18 and page 19
Maintenance
Refrigerant work restricted to certified contractors

Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the R-449A charge of 2.1 t CO2 equivalent may also trigger leak-check and record-keeping obligations under refrigerant regulations.

Unichiller Operation Manual, page 17; Datasheet, page 1

Selection & Integration Q&A

When should I choose the P230-H instead of a 110T or 110Tw sibling?

Pick the P230-H for high-pressure-drop process loops, since the 'P' marks suitability for such applications, and when the -20…100 °C window with up to 23 kW at 20 °C fits. The 110T/110Tw siblings differ in noise level (74 vs 65 dB(A)) and should be compared on that basis.

What must the site provide for the electrical and hydraulic connection?

A 460 V 3~ 60 Hz supply with UL 489 branch protection and a suitable plug, since the unit arrives with cable but no plug below 63 A. The process loop must be closed, match G1 1/4 male threads, and hold at least 18 l with 48 l expansion volume.

What mounting and ambient limits apply to this air-cooled unit?

Install indoors, outside ATEX zones, at 5…40 °C ambient with at least 300 lx lighting and up to 2000 m altitude. Keep 50–200 cm wall clearance per side for maintenance and airflow, and activate leveling feet or parking brakes before start-up.

What maintenance and accessory scope is not included in base delivery?

The plug and UL 489 breaker are site scope, and refrigerant-circuit service must be performed by approved contractors. The manual covers maintenance and shutdown procedures; hoses, couplings and thermal fluid for the G1 1/4 connections are not part of the unit delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P230-H Datasheet
Datasheet ·200,1 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF