Peter Huber Kältemaschinenbau Unichiller P180
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P180

Peter Huber Kältemaschinenbau Unichiller P180 — Recirculating chillers.

The Unichiller P180 is a free-standing, air-cooled recirculating chiller with a non-variable E2 pressure pump and G1 1/4 male connections, rated -20 to 40 °C. Its 'P' designation targets process loops with high pressure drop, where cooling capacity falls from 20 kW at 20 °C to 6 kW at -10 °C. It serves externally closed industrial cooling circuits requiring Pilot ONE control and Ethernet/RS232/USB data access.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller P180 Current E2I / NFL-20–40—0.0480.018
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 48 l
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...40 °C
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 20 kW (at 20 °C)
at 0 °C: 18 kW · at -10 °C: 6 kW
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior under load and temperature

Control, installation and operation

Integration & Operating Notes

Electrical
Site power must match 460 V 3~ 60 Hz exactly

The unit is configured for a 460 V three-phase 60 Hz supply. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and the datasheet explicitly forbids -5% voltage combined with +2% frequency. Verify the site configuration before ordering; a mismatched supply prevents commissioning.

Unichiller P180 Datasheet, Technical Specifications
Electrical
Provide plug or hardwiring plus UL 489 branch protection

Three-phase devices drawing less than 63 A are supplied with cable but without a plug, so the installer must provide a suitable plug or hardwire the unit. External branch circuit protection according to UL 489 is required and must be sized from the electrical schematics.

Unichiller P180 Datasheet, Installation notes
Mounting
Keep 50–200 cm wall clearance per side for service

Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance access. The cabinet is 938 x 1288 x 2003 mm, so door widths, ceiling height and service routes must be planned for this footprint before delivery.

Unichiller Operation Manual, Setup Mode
Mounting
Indoor site only, at least 300 lx, below 2000 m

The manual restricts use to indoor locations with illuminance of at least 300 lx and a maximum altitude of 2000 m. Ambient temperature must stay between 5 and 40 °C; outside this window cooling capacity drops and reliability is affected. The unit is not explosion-protected and must not be installed in an ATEX zone.

Unichiller Operation Manual, Setup Mode
Process Limits
Externally closed loop with at least 18 l fill

The chiller is designed only for externally closed applications. Minimum filling capacity is 18 l and expansion volume is 48 l, which sets the minimum loop volume and expansion headroom; undersized loops cause control and overflow problems. The G1 1/4 male pump connection requires matching hoses and fittings.

Unichiller P180 Datasheet, Technical Specifications; Operation Manual, Function Description
Process Limits
Size capacity at the real operating temperature

Cooling capacity falls from 20 kW at 20 °C to 6 kW at -10 °C and 3.5 kW at -20 °C. Capacity figures are valid at 20 °C room temperature and may drop as ambient rises. Selection based on the nominal +20 °C figure will undersize low-temperature duty.

Unichiller P180 Datasheet, Technical Specifications
Control & I/O
Configure power-failure response before unattended runs

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. The chosen behavior determines whether the process restarts automatically after an outage; select it deliberately for the process risk profile rather than leaving the default.

Unichiller Operation Manual, Normal Operation
Control & I/O
Process Safety mode applies full cooling at OT trigger

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature trigger value is reached, instead of switching off all poles. This is relevant for exothermic processes where cutting cooling would cause runaway temperatures; confirm the mode matches the process hazard analysis.

Unichiller Operation Manual, Normal Operation
Maintenance
Refrigerant work restricted to approved contractors

Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. The R-449A charge (GWP 1397, 2.1 t CO2 equivalent) also triggers leak-check and record-keeping obligations in many jurisdictions; plan service access accordingly.

Unichiller Operation Manual, Maintenance

Selection & Integration Q&A

When should I choose the Unichiller P180 instead of a sibling Unichiller 110T variant?

Choose the P180 when the process loop has high pressure drop, since the 'P' designation and E2 pressure pump target that duty. The 110T family differs mainly in acoustic profile (74 vs 65 dB(A) for Tw variants); select those when noise is the deciding constraint rather than loop pressure drop.

What must the site power and branch protection provide for this chiller?

A 460 V 3~ 60 Hz supply within ±5% voltage and ±2% frequency, with the combination -5% voltage and +2% frequency explicitly not allowed. The unit arrives with cable but no plug (below 63 A), so provide a plug or hardwiring plus external UL 489 branch protection sized from the schematics.

What mounting and ambient limits apply to the P180 installation?

Indoors only, at least 300 lx, altitude up to 2000 m, ambient 5–40 °C, with 50–200 cm wall clearance per side for maintenance. It is not explosion-protected, so no ATEX zone. Set leveling feet or parking brakes before start-up, and check refrigerant charge against room volume.

What is not included in base delivery and what service obligations should be planned?

No plug is supplied for the three-phase cable, and no mating hoses or G1 1/4 fittings are included. Refrigerant circuit work requires approved refrigeration contractors, and the R-449A charge (2.1 t CO2e) brings leak-check and record-keeping duties; cooling water must be shut off even overnight.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P180 Recirculating Chiller Datasheet
Datasheet ·18,0 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF