Peter Huber Kältemaschinenbau Unichiller P180w-H
Peter Huber Kältemaschinenbau Unichiller P180w-H — Recirculating chillers.
The Unichiller P180w-H is a water-cooled recirculating chiller with a fixed-speed E2 pressure pump (G1 1/4 male), rated -20...100 °C and 140 l/min max delivery, built for externally closed loops with high pressure drop. Its 460 V 3~ 60 Hz supply, 2 kW heater and 48 l expansion volume distinguish this 'P' modification from the 110T/Tw siblings.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller P180w-H Current | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 48 l |
| Heating capacity | 2 kW |
| Maximum delivery flow rate | 140 l/min (pressure pump max delivery) |
| Minimum fill volume | 18 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | E2 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit using R-449A (GWP 1397, 2.1 t CO2e); cooling water connections G3/4 male, circuit materials copper, 1.4401 stainless steel, MS, PA, PPE, PTFE and EPDM.
- 'P' in the model name marks this unit as suited to process loops with high pressure drop; the E2 pressure pump is fixed-speed (not adjustable) and delivers up to 140 l/min.
- Compared with the Unichiller 110T/Tw siblings, this is the P180w-H modification: water-cooled rather than air-cooled, with a 2 kW heater and 48 l expansion volume. Sibling noise figures (74 dB(A) for 110T, 65 dB(A) for 110Tw) are not transferable to this model.
Working range and media behavior
- Temperature range -20...100 °C; minimum fill volume 18 l, expansion volume 48 l.
- Cooling water inlet must be 5...20 °C; higher cooling water temperature reduces cooling power and may require increased cooling water flow. Below the condensation point, cooling water pipes inside the unit must be insulated.
- Ambient rating 5...40 °C; intended only for externally closed applications.
Control, installation and operation
- Pilot ONE controller with Ethernet, USB (host and device) and RS232; external Pt100 sensor connection; adjustable overtemperature protection to DIN 12876, safety class III/FL.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto; Process Safety mode releases maximum cooling capacity at the OT trigger instead of switching off.
- IP20, Class A Group 1 to EN55011; external branch protection to UL 489 required; three-phase units below 63 A are supplied with cable but without plug.
Integration & Operating Notes
Site utility design must guarantee cooling water inlet temperature between 5 and 20 °C. Above this band cooling power drops and the required cooling water flow rate may rise; below the condensation point the internal cooling water pipes must be insulated to prevent condensate and corrosion.
The unit needs a 460 V 3~ 60 Hz supply with voltage tolerance ±5% only together with frequency tolerance ±2%. External branch circuit protection according to UL 489 is mandatory. Three-phase devices drawing less than 63 A arrive with cable but without plug, so the installer must provide the termination.
Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance access. Before start-up the parking brakes must be applied at the casters and/or leveling feet unscrewed. Indoor use only, illuminance at least 300 lx, altitude up to 2000 m; not permitted in ATEX zones.
The chiller is designed exclusively for externally closed applications. When connecting hoses to the G1 1/4 male pump connection, the fittings must be counterheld and the maximum tightening torques must not be exceeded to avoid damage and leaks.
With adjustable overtemperature protection to DIN 12876, the controller can either switch off all poles at the OT trigger or, in Process Safety mode, release maximum cooling capacity. For exothermic processes the latter prevents runaway temperature; the power-failure response (OFF/Standby, ON, Power Failure Auto) must be selected to match the process restart policy.
Selection & Integration Q&A
Pick the P180w-H when the process loop has high pressure drop (the 'P' designation) and you have a 460 V 3~ 60 Hz supply plus cooling water at 5...20 °C. The 110T/Tw siblings are air-cooled alternatives; their noise figures do not apply here.
Cooling water at 5...20 °C on G3/4 male connections, with insulation if below the condensation point. Electrical: 460 V 3~ 60 Hz, ±5% voltage with ±2% frequency, UL 489 branch protection, and a field-supplied plug since units below 63 A ship with cable only.
Indoors only, 5...40 °C ambient, at least 300 lx, up to 2000 m altitude, never in an ATEX zone. Allow 50–200 cm wall clearance per side for maintenance, apply caster parking brakes or leveling feet, and protect electrical lines below the unit from condensate.
The base unit ships without a plug (three-phase <63 A) and without external Pt100 sensor unless ordered. Cooling water must be shut off even overnight; refrigerant circuit service only by approved contractors. No consumables or cable sets are included in the verified scope.