Peter Huber Kältemaschinenbau Unichiller P180w-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P180w-H

Peter Huber Kältemaschinenbau Unichiller P180w-H — Recirculating chillers.

The Unichiller P180w-H is a water-cooled recirculating chiller with a fixed-speed E2 pressure pump (G1 1/4 male), rated -20...100 °C and 140 l/min max delivery, built for externally closed loops with high pressure drop. Its 460 V 3~ 60 Hz supply, 2 kW heater and 48 l expansion volume distinguish this 'P' modification from the 110T/Tw siblings.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller P180w-H Current E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 48 l
Heating capacity 2 kW
Maximum delivery flow rate 140 l/min (pressure pump max delivery)
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media behavior

Control, installation and operation

Integration & Operating Notes

Process Limits
Cooling water must stay within 5...20 °C at the inlet

Site utility design must guarantee cooling water inlet temperature between 5 and 20 °C. Above this band cooling power drops and the required cooling water flow rate may rise; below the condensation point the internal cooling water pipes must be insulated to prevent condensate and corrosion.

Unichiller P180w-H Datasheet, Technical Specifications
Electrical
Plan branch protection to UL 489 and a field-made plug

The unit needs a 460 V 3~ 60 Hz supply with voltage tolerance ±5% only together with frequency tolerance ±2%. External branch circuit protection according to UL 489 is mandatory. Three-phase devices drawing less than 63 A arrive with cable but without plug, so the installer must provide the termination.

Unichiller P180w-H Datasheet, Technical Specifications
Mounting
Keep 50–200 cm clearance per side and lock the casters

Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance access. Before start-up the parking brakes must be applied at the casters and/or leveling feet unscrewed. Indoor use only, illuminance at least 300 lx, altitude up to 2000 m; not permitted in ATEX zones.

Unichiller Operation Manual, Installation
Process Limits
Closed-loop hydraulics only; counterhold pump fittings

The chiller is designed exclusively for externally closed applications. When connecting hoses to the G1 1/4 male pump connection, the fittings must be counterheld and the maximum tightening torques must not be exceeded to avoid damage and leaks.

Unichiller Operation Manual, Commissioning
Safety
Choose Process Safety mode for exothermic reactions

With adjustable overtemperature protection to DIN 12876, the controller can either switch off all poles at the OT trigger or, in Process Safety mode, release maximum cooling capacity. For exothermic processes the latter prevents runaway temperature; the power-failure response (OFF/Standby, ON, Power Failure Auto) must be selected to match the process restart policy.

Unichiller Operation Manual, Setup Mode

Selection & Integration Q&A

When should I choose the P180w-H instead of a Unichiller 110T or 110Tw sibling?

Pick the P180w-H when the process loop has high pressure drop (the 'P' designation) and you have a 460 V 3~ 60 Hz supply plus cooling water at 5...20 °C. The 110T/Tw siblings are air-cooled alternatives; their noise figures do not apply here.

What must the site provide for the cooling water and electrical connection?

Cooling water at 5...20 °C on G3/4 male connections, with insulation if below the condensation point. Electrical: 460 V 3~ 60 Hz, ±5% voltage with ±2% frequency, UL 489 branch protection, and a field-supplied plug since units below 63 A ship with cable only.

Where can the unit be installed and how must it be secured before start-up?

Indoors only, 5...40 °C ambient, at least 300 lx, up to 2000 m altitude, never in an ATEX zone. Allow 50–200 cm wall clearance per side for maintenance, apply caster parking brakes or leveling feet, and protect electrical lines below the unit from condensate.

What maintenance and accessories are required beyond the base delivery?

The base unit ships without a plug (three-phase <63 A) and without external Pt100 sensor unless ordered. Cooling water must be shut off even overnight; refrigerant circuit service only by approved contractors. No consumables or cable sets are included in the verified scope.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P180w-H Recirculating Chiller Datasheet
Datasheet ·18,3 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF