Peter Huber Kältemaschinenbau Unichiller 130Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 130Tw

Peter Huber Kältemaschinenbau Unichiller 130Tw — Recirculating chillers with Noise level 65 dB.

The Unichiller 130Tw is a water-cooled recirculating chiller for externally closed circuits, rated -20 to 40 °C with a C3 fixed-speed pump (96 l/min, 5.6 bar). Its 'w' variant is the low-noise (65 dB(A)) water-cooled member of the 110/130 series, distinguished from air-cooled siblings by a G3/4 cooling-water connection and 150–500 l/h water demand.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 130Tw Current C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type C3
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 229 kg
Electrical, Power & Drive Specifications
Current consumption 12 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 150 л/час (at 15°C, flow -10°C)
at 15°C, flow 0°C: 280 l/h · at 15°C, flow 15°C: 500 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior and media

Control and operation

Integration & Operating Notes

Cooling & Media
Facility water must stay within 5–20 °C and 1–6 bar

Below 1 bar differential the chiller cannot reject its rated load; above 6 bar the water circuit is at risk. Cooling power drops and flow demand rises as inlet water warms, so size the supply for the worst-case 20 °C condition, not the nominal 15 °C.

Unichiller 130Tw Technical Data, Specifications
Cooling & Media
Shut off cooling water even for overnight downtime

Leaving the water supply open during idle periods invites condensation, corrosion and water damage inside the unit. Isolate the supply whenever the chiller is not actively cooling, including short overnight stops.

Unichiller Operation Manual, Commissioning
Mounting
Allow 50–200 cm wall clearance per side for service

Free-standing installation requires this access envelope on either side for maintenance. Also protect any electrical lines routed directly below the unit against liquid ingress from condensation, and keep the unit out of ATEX zones — it is not explosion-protected.

Unichiller Operation Manual, Installation
Electrical
Delivered with cable but no plug — provide one on site

Three-phase devices drawing under 63 A ship with a cable only; the mating plug is a site responsibility. Supply tolerance is ±5% voltage with simultaneous ±2% frequency, and only permitted combinations apply. The unit is EN 55011 Class A, Group 1, so EMC measures may be needed in sensitive environments.

Unichiller 130Tw Technical Data, Specifications
Process Limits
Closed-loop circuits only — no open tanks

The chiller is designed exclusively for externally closed applications. An open bath or vented tank will not match the hydraulic design and risks pump and temperature-control problems. Verify the external loop pressure drop against the fixed C3 pump curve (96 l/min, 5.6 bar).

Unichiller Operation Manual, Function Description
Control & I/O
Choose power-failure mode deliberately for exothermic loads

Pilot ONE offers OFF/Standby, ON or Power Failure Auto after mains loss. For processes that generate heat, Process Safety mode should be configured so maximum cooling is released at the overtemperature trigger rather than all poles switching off.

Unichiller Operation Manual, Normal Operation
Maintenance
Refrigerant work restricted to approved contractors

Any intervention on the refrigerant circuit must be performed by approved refrigeration/air-conditioning contractors. The R-449A charge (GWP 1397, 2.9 t CO2e) also triggers leak-check and reporting obligations; confirm room volume against the charge limit at installation.

Unichiller Operation Manual, Maintenance

Selection & Integration Q&A

When should I choose the 130Tw over the air-cooled 110T or the smaller 110Tw?

Pick the 130Tw when heat must be rejected to facility water and low noise (65 dB(A)) matters; air-cooled 110T/110T-H are 74 dB(A) and dump heat into the room. The 110Tw shares the water-cooled 65 dB(A) platform but at lower capacity — choose it only if its cooling output covers the load.

What facility water supply and piping must be provided for the 130Tw?

A G3/4 male connection fed with 5–20 °C water at 1–6 bar differential; flow demand is 150–500 l/h depending on setpoint. Use only water compatible with copper, 1.4401 stainless, MS, PA, PPE, PTFE and EPDM, and insulate pipes where condensation can form.

What installation and duty-cycle limits apply from the manual?

Indoor use only, 5–40 °C ambient, ≥300 lx lighting, up to 2000 m altitude, 50–200 cm side clearance, leveling feet/parking brakes set before start-up, and no ATEX zone. IP20 means a dry location protected from water ingress.

What is not included in base delivery and what service obligations follow?

The three-phase cable is supplied without a plug, so the mating plug is on site. Refrigerant-circuit service is limited to approved contractors; the R-449A charge (2.9 t CO2e) carries leak-check and reporting duties, and cooling water must be isolated during downtime.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 130Tw Technical Data
Datasheet ·79,7 КБ ·2 pp.
View PDF