Peter Huber Kältemaschinenbau Unichiller 160Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 160Tw

Peter Huber Kältemaschinenbau Unichiller 160Tw — Recirculating chillers with Noise level 65 dB.

The Unichiller 160Tw is a water-cooled recirculating chiller with a 96 l/min pump and 10 l expansion volume, operating from -20 to 40 °C. It is the low-noise (65 dB(A)) variant in the series, distinguished from the 110T/110T-H siblings (74 dB(A)). It serves externally closed cooling circuits requiring a 400 V 3~ supply and G1 1/4 pump connection.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 160Tw Current C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Expansion volume 10 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type C3
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 225 kg
Electrical, Power & Drive Specifications
Current consumption 12 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 133 л/час (at 15°C, flow -10°C)
at 15°C, flow 0°C: 320 l/h · at 15°C, flow 15°C: 600 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for maintenance access

Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance and service access. Plan the installation footprint accordingly, and ensure the unit is indoors with illuminance of at least 300 lx and at an altitude not exceeding 2000 m.

Operation Manual, Section on Installation
Electrical
Provide a 3x16 A fused supply and a suitable plug on site

The unit draws up to 12 A per phase at 400 V 3~ 50 Hz and requires 3x16 A fusing. Three-phase devices with current consumption below 63 A are delivered with cable but without a plug, so the installer must provide a compatible plug and connection. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%; combinations such as -5% voltage with +2% frequency are not allowed.

Datasheet, Technical Specifications
Process Limits
Cooling water must be 5–20 °C and 1–6 bar

The chiller is designed for cooling water intake between 5 °C and 20 °C, with a minimum differential pressure of 1 bar and a maximum pressure of 6 bar. Higher cooling water temperature reduces cooling power and may require increased flow rate. Insulate pipes if water temperature can fall below the condensation point.

Datasheet, Technical Specifications
Cooling & Media
Use only water compatible with copper, stainless steel and EPDM

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Ensure the cooling water is chemically compatible with these materials to avoid corrosion or damage. The unit is intended for externally closed applications only.

Datasheet, Technical Specifications
Operation
Shut off cooling water during even short downtimes

Shut off the cooling water supply to the unit even for shorter downtimes such as overnight to prevent water damage and corrosion. Also protect electrical lines directly below the unit against liquid ingress from condensation.

Operation Manual, Section on Installation
Safety
Configure power-failure response and overtemperature mode

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles. Select the mode that matches the process risk.

Operation Manual, Sections on Setup Mode and Safety
Maintenance
Refrigerant circuit work requires certified contractors

Work on the refrigerant circuit must only be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-449A with a charge of 2.1 kg; observe the refrigerant quantity and room size to avoid exceeding the limit per m³ of ambient air.

Operation Manual, Section on Maintenance

Selection & Integration Q&A

When should I choose the Unichiller 160Tw over the 110T or 110T-H siblings?

Choose the 160Tw when lower noise (65 dB(A) vs 74 dB(A) for 110T/110T-H) is required. The 110T variants offer higher cooling capacity but are louder. The 160Tw is also water-cooled and suited to externally closed circuits; for high pressure-drop loops, consider a model with “P” in the name.

What are the requirements for the cooling water supply and the process circuit connections?

Cooling water: 5–20 °C inlet, 1 bar min. differential, 6 bar max., G3/4 male connections. Process circuit: G1 1/4 AG male pump connection, externally closed loop, min. filling 6.5 l, expansion volume 10 l. Ensure water compatibility with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.

What are the mounting and ambient limits for this chiller?

Install indoors only, at 5–40 °C ambient, illuminance ≥300 lx, altitude ≤2000 m. Maintain 50–200 cm side clearance for maintenance. Do not install in an ATEX zone. Leveling feet or parking brakes must be engaged before start-up. Protect electrical lines below the unit from condensation.

What maintenance and accessories are required that are not included in the base delivery?

The unit is delivered with cable but without a plug for three-phase supply; provide a suitable 3x16 A plug. Refrigerant circuit work must be by certified contractors. Shut off cooling water during downtimes. No specific maintenance intervals are stated in the provided documents; follow the manual’s maintenance section.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 160Tw Technical Data
Datasheet ·81,0 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF