Peter Huber Kältemaschinenbau Unichiller 160T-H
Peter Huber Kältemaschinenbau Unichiller 160T-H — Recirculating chillers.
The Unichiller 160T-H is a recirculating chiller with a 16 kW cooling capacity at 15 °C, designed for externally closed applications. It operates from -10 to 100 °C with a 2 kW heater and a fixed-speed C3 pump delivering up to 99 l/min. This modification is distinguished within the series by its higher capacity and heating function, serving as a central cooling source for process loops.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 160T-H Current | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | C3 |
| External sensor connection | Pt100 |
| Temperature range | -10...100 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and Series Positioning
The Unichiller 160T-H is a free-standing, air-cooled recirculating chiller built for indoor installation. It is equipped with a 2 kW heater, enabling both cooling and heating within the -10 to 100 °C range. The pump is a fixed-speed C3 type with G1 1/4 male connections, delivering a maximum flow of 99 l/min and a maximum pressure of 5.9 bar. The unit uses R-449A refrigerant and has a 39 l expansion volume with a 14 l minimum fill. Compared to sibling models such as the Unichiller 110T-H, this model offers higher cooling capacity (16 kW at 15 °C) and is intended for larger heat loads. The 'T' designation indicates a standard (non-water-cooled) variant, while the 'H' denotes the integrated heater.
Performance and Operating Behavior
Cooling capacity is strongly temperature-dependent: 16 kW at 15 °C, 8.8 kW at 0 °C, and 4 kW at -10 °C. This means low-temperature duty requires careful sizing to avoid insufficient capacity. The unit is designed exclusively for externally closed circuits; open baths or tanks are not permitted. The Pilot ONE controller manages temperature and offers configurable power-failure response (OFF/Standby, ON, or Power Failure Auto). For exothermic processes, the Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than shutting down all poles.
Installation, Control and Operation
The chiller requires a 400 V three-phase 50 Hz supply and is delivered with a cable but without a plug (for currents below 63 A). It must be installed indoors in a dry location (IP20), with a wall clearance of 50–200 cm per side for maintenance. Ambient temperature must remain between 5 and 40 °C; cooling capacity is rated at 20 °C room temperature and may derate above that. The unit is EMC class A group 1 and may cause radio interference in residential areas. Refrigerant charge and room size must be checked to avoid exceeding the refrigerant limit per m³. Leveling feet or parking brakes must be engaged before operation. The Pilot ONE provides Ethernet, USB (host and device), and RS232 interfaces for remote control and data logging.
Integration & Operating Notes
The manual requires a wall clearance of 50 to 200 cm on either side of free-standing models to allow maintenance and ensure adequate airflow. Insufficient clearance can lead to overheating and reduced cooling capacity, and will hinder service access to the refrigerant circuit.
The unit requires a three-phase 400 V 50 Hz supply. Voltage tolerance is ±5% with a simultaneous frequency tolerance of ±2%, but not all combinations are permitted. The customer must provide a suitable disconnector or plug, as the unit is delivered with a cable but without a plug for currents below 63 A.
The chiller is designed exclusively for externally closed applications. Connecting an open bath or tank will cause fluid evaporation, corrosion, and potential pump damage. Ensure the external circuit is sealed and compatible with the thermal fluid.
Cooling capacity drops from 16 kW at 15 °C to 4 kW at -10 °C. When sizing for low-temperature processes, the heat load must be reduced accordingly or a larger chiller selected. Capacity is rated at 20 °C ambient; higher ambient temperatures may further reduce performance.
The Pilot ONE controller allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For processes where automatic restart is hazardous, select OFF/Standby. For exothermic reactions, enable Process Safety mode to release maximum cooling on overtemperature instead of shutting down.
Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A (GHS H280) requires proper ventilation and handling. Regular maintenance should include checking the refrigerant charge and room size to avoid exceeding the limit per m³.
Selection & Integration Q&A
Choose the 160T-H for higher cooling capacity (16 kW at 15 °C) and a 2 kW heater. The 110T-H offers lower capacity (likely around 11 kW) and is suitable for smaller loads. The 110Tw-H is water-cooled and produces less noise (65 dB(A) vs 74 dB(A)), making it preferable where noise or heat rejection to air is a concern.
The pump connection is G1 1/4 male, so use mating hoses or adapters with G1 1/4 female threads. Ensure the external circuit is closed and can withstand the pump's maximum pressure of 5.9 bar. The minimum fill volume is 14 l, and the expansion volume is 39 l; verify your loop volume is compatible.
Install indoors in a dry location (IP20), with ambient temperature between 5 and 40 °C. Maintain 50–200 cm clearance on each side for maintenance. Avoid ATEX zones. The unit is EMC class A group 1, so it may cause radio interference in residential areas; additional shielding may be needed.
The unit is delivered with a cable but without a plug; you must provide a suitable disconnector. Refrigerant circuit work must be done by certified contractors. Regular maintenance includes checking refrigerant charge and room size. No hoses, adapters, or thermal fluid are included; these must be sourced separately to match G1 1/4 connections.