Peter Huber Kältemaschinenbau Unichiller 300Tw-H
Peter Huber Kältemaschinenbau Unichiller 300Tw-H — Recirculating chillers.
The Unichiller 300Tw-H is a water-cooled recirculating chiller with a 400 V three-phase feed, a Pilot ONE controller and a non-variable D3 pressure pump, covering -20 to 100 °C. Within the Unichiller series it is the 300-size Tw-H modification, distinguished by its higher cooling capacity and water-cooled condenser. It serves externally closed process loops that need stable temperature control with heat removal down to -20 °C.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 300Tw-H Current | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 22 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 15 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 0 °C) at -10 °C: 18 kW · at -20 °C: 13 kW |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The 300Tw-H is a water-cooled (Tw) recirculating chiller with heating capability (H suffix). It is built around a refrigerant circuit using R-449A (GWP 1397) and a cooling-water heat exchanger whose wetted materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. The unit is rated IP20 and safety class III/FL. Compared with the sibling Unichiller 110T/110Tw models, the 300Tw-H is the larger-capacity frame in this data set; the 110-series siblings are air-cooled (T) or water-cooled (Tw) 110-size units with lower noise figures (65–74 dB(A)), whereas the 300Tw-H is specified for higher cooling duty. Selection between them should follow the required cooling capacity at the target temperature and the available cooling-water supply, not the model number alone.
Thermal behavior and operating envelope
Cooling capacity is strongly temperature-dependent: 18 kW at -10 °C, 13 kW at -20 °C and 15 kW at 0 °C (spec table). The heating capacity is 2 kW. The working temperature range is -20 to 100 °C. The circulation pump is a D3 pressure pump with fixed speed (not adjustable), delivering up to 210 l/min, with flow declining as external pressure drop rises (202 l/min at 1.1 bar). Because pump speed cannot be trimmed, the process loop must be designed so that its pressure drop at the required flow stays within the pump curve.
Installation, connection and control
The unit requires a 400 V 3~ 50 Hz supply with voltage tolerance ±5% and simultaneous frequency tolerance ±2%; three-phase devices below 63 A are delivered with a cable but without a plug, so a suitable plug must be provided on site. Pump connection is G1 1/4 male and cooling-water connection is G3/4 male; matching fittings and hoses are required. Cooling water must be supplied at 5–20 °C inlet with a differential pressure of at least 1 bar and a maximum pressure of 6 bar; pipes must be insulated if below the condensation point. The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, an external Pt100 sensor input, and configurable power-failure response (OFF/Standby, ON, Power Failure Auto). Adjustable overtemperature protection to DIN 12876 is provided, with a Process Safety mode that releases maximum cooling capacity when the OT trigger is reached.
Integration & Operating Notes
The chiller is designed for cooling-water intake between 5 °C and 20 °C. Differential pressure must be at least 1 bar and must never exceed 6 bar. Insulate cooling-water pipes if their surface temperature can fall below the condensation point. Only water compatible with the copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM materials of the cooling-water circuit should be used.
The unit is not explosion-protected and must not be installed or started up inside an ATEX zone. Ambient temperature must remain between 5 °C and 40 °C for reliable operation. The IP20 rating means the enclosure must be kept in a dry indoor location protected from water and dust ingress.
Selection & Integration Q&A
Choose the 300Tw-H when the required cooling capacity at your setpoint exceeds what the 110-size frame can deliver; the 300Tw-H provides 18 kW at -10 °C, 13 kW at -20 °C and 15 kW at 0 °C. The 110Tw-H is a smaller water-cooled unit with a 65 dB(A) noise figure. Both need a cooling-water supply; confirm capacity at your actual temperature before deciding.
Provide cooling water at 5–20 °C inlet with a differential pressure of at least 1 bar and a maximum of 6 bar. The cooling-water connection is G3/4 male and the pump connection is G1 1/4 male, so matching hoses and adapters are needed. Insulate cooling-water pipes if they can drop below the condensation point.
The base delivery includes a cable but no plug for the 400 V three-phase feed, so a suitable plug must be supplied on site. Cooling-water hoses and G3/4 and G1 1/4 fittings are not included. Shut off cooling water even overnight. Refrigerant-circuit service must be performed by approved contractors; no consumables or spare-part intervals are stated in the provided documents.