Peter Huber Kältemaschinenbau Unichiller GL 300w
Peter Huber Kältemaschinenbau Unichiller GL 300w — Recirculating chillers.
The Unichiller GL 300w is a water-cooled recirculating chiller with a 30 l expansion volume, a fixed-speed pressure pump delivering up to 100 l/min at 3.5 bar, and a -20…40 °C working range. It is the water-cooled GL variant in the Unichiller series, distinguished from air-cooled siblings by its G3/4 cooling-water circuit. It serves externally closed process loops requiring stable temperature control with Pilot ONE electronics.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller GL 300w Current | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 30 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled condenser circuit (R-744/CO2, safety group A1) with G3/4 male cooling-water connections; requires 1–6 bar differential pressure at the connection.
- Fixed-speed pressure pump with G1 1/4 AG male process connections; no variable-speed control.
- 30 l expansion volume and -20…40 °C temperature range; Pilot ONE controller with Ethernet, USB host/device and RS232.
- Sibling Unichiller 110T variants are air-cooled (74 dB(A)) or water-cooled (65 dB(A)); the GL 300w is the water-cooled configuration with a larger 30 l expansion volume and 100 l/min pump delivery.
Behavior under load and media
- Cooling power decreases as cooling-water inlet temperature rises, and required cooling-water flow may increase; design the water supply for the worst-case inlet temperature.
- Cooling-water inlet temperature is specified for 5…20 °C; lower temperatures require insulation of the cooling-water pipes to prevent condensation.
- The cooling-water circuit materials (copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM) constrain water quality; only compatible water may be used.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles — relevant for exothermic loads.
Installation, connection and control
- Three-phase 400 V 3~ 50 Hz supply; devices under 63 A are supplied with cable but without plug, so the installer must provide a suitable plug or hardwired connection.
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; combinations such as -5% voltage and +2% frequency are not permitted.
- IP20 protection requires a dry indoor location; electrical lines directly below the unit must be protected against liquid ingress from condensation.
- Wall clearance of 50–200 cm per side is required for maintenance on free-standing models; leveling feet or parking brakes must be engaged before start-up.
- Power-failure response is configurable via Pilot ONE as OFF/Standby, ON, or Power Failure Auto.
Integration & Operating Notes
Operating with cooling-water inlet below 5 °C or above 20 °C is outside the design range; lower temperatures require insulation of the cooling-water pipes to prevent condensation on the circuit and adjacent electrical lines.
The supply must provide at least 1 bar differential pressure to achieve design flow, and must never exceed 6 bar at the connection; exceeding the maximum risks damage to the cooling-water circuit and connections.
Because current consumption is below 63 A, the unit ships with a cable only; the installer must provide a suitable plug or hardwired connection rated for the 400 V 3~ 50 Hz supply.
Free-standing models require this wall clearance on either side to allow maintenance access; also verify room volume against the refrigerant charge on the rating plate to avoid exceeding the permissible refrigerant concentration per m³ of ambient air.
The unit is not explosion-protected and must not be installed or started inside an ATEX zone; it is for indoor use at illuminance of at least 300 lx and up to 2000 m altitude.
The hydraulic circuit must be designed as an externally closed loop; open baths or vented circuits are outside the intended application and may cause pump cavitation or overflow.
Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the refrigerant is R-744 (CO2), safety group A1, GHS H280, UN 2857.
Close the cooling-water supply to the unit during any downtime, including short overnight stops, to prevent water damage and corrosion in the cooling-water circuit.
Selection & Integration Q&A
Choose the GL 300w when a cooling-water circuit with 1–6 bar differential pressure is available and the 30 l expansion volume and 100 l/min pump delivery suit the loop. Air-cooled 110T variants avoid water connections but are louder (74 dB(A) vs 65 dB(A) for water-cooled 110Tw).
Provide a cooling-water circuit with G3/4 male mating connections, differential pressure between 1 and 6 bar, and inlet temperature 5–20 °C. Use water compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; insulate pipes if inlet is below 5 °C.
Indoor use only, 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, not in an ATEX zone. Free-standing models need 50–200 cm wall clearance per side; engage leveling feet or parking brakes before start-up and protect electrical lines below the unit from condensation.
The three-phase unit ships with a cable but no plug; the installer must provide a suitable plug or hardwired connection. Refrigerant-circuit work is restricted to approved refrigeration contractors. Shut off cooling water during any downtime, including overnight.