Peter Huber Kältemaschinenbau Unichiller 250T-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 250T-H

Peter Huber Kältemaschinenbau Unichiller 250T-H — Recirculating chillers.

The Unichiller 250T-H is a 400 V three-phase, air-cooled recirculating chiller with a Pilot ONE controller and a fixed-speed D3 pump (210 l/min, 4.7 bar max). It delivers 18 kW at 0 °C and 6 kW at -20 °C within a -20…100 °C range, distinguishing it from lower-capacity 110T siblings. It serves externally closed industrial cooling loops requiring 14–39 l fill and G1 1/4 male connections.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 250T-H Current D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Heating capacity 2 kW
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 25 °C)
at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Electrical
Three-phase units below 63 A ship without a plug

The installer must provide a suitable mating plug for the supplied cable. Plan for a 400 V 3~ 50 Hz supply with appropriate overcurrent protection; the unit does not include a plug for direct connection.

Unichiller 250T-H Technical Datasheet, page 2
Mounting
Maintain 50–200 cm wall clearance per side for maintenance

Free-standing models require this clearance on either side to allow service access and adequate air flow for heat rejection. Insufficient clearance will reduce cooling capacity and may cause overheating.

Unichiller Operation Manual, page 25
Mounting
Indoor use only, minimum 300 lx illuminance, max 2000 m altitude

The unit is not explosion-protected and must not be installed in an ATEX zone. It requires a dry, protected environment (IP20) and sufficient lighting for safe operation and maintenance.

Unichiller Operation Manual, page 25
Process Limits
Externally closed applications only; minimum fill 14 l

The hydraulic circuit must be closed and have a minimum volume of 14 l to ensure stable pump operation and sufficient thermal mass. The expansion volume is 39 l; do not exceed the maximum fill or the expansion tank may overflow.

Unichiller Operation Manual, page 34; Datasheet page 1
Process Limits
Cooling capacity drops as ambient temperature rises above 20 °C

Rated capacities are valid at 20 °C room temperature. If the installation site ambient exceeds this, available cooling at each temperature setpoint will be lower; size the unit with margin or provide additional ventilation.

Unichiller 250T-H Technical Datasheet, page 2
Control & I/O
Configure power-failure response to match process restart needs

The Pilot ONE allows OFF/Standby, ON, or Power Failure Auto. For unattended processes, Power Failure Auto restarts automatically; for safety-critical exothermic reactions, choose OFF/Standby to prevent uncontrolled restart.

Unichiller Operation Manual, page 19
Control & I/O
Process Safety mode releases maximum cooling on OT trip

Instead of switching off all poles, this mode activates full cooling when the overtemperature trigger is reached. Use only when the process requires rapid heat removal to prevent runaway; otherwise standard OT shutdown is safer.

Unichiller Operation Manual, page 18
Maintenance
Refrigerant circuit work only by approved contractors

Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A is classified A1 with GHS hazard H280 (pressurized gas); observe room size and charge limits.

Unichiller Operation Manual, page 17; Datasheet page 1

Selection & Integration Q&A

When should I choose the Unichiller 250T-H over the 110T or 110Tw siblings?

Choose the 250T-H when you need higher cooling capacity (18 kW at 0 °C vs lower for 110T) and a -20…100 °C range. The 110Tw offers lower noise (65 dB(A)) but less capacity; select 250T-H for high heat loads, 110Tw for noise-sensitive areas with lower demand.

What are the requirements for connecting the 250T-H to my process loop?

Use G1 1/4 male connections with hoses rated for the max pressure (4.7 bar) and temperature. Ensure the loop is externally closed with at least 14 l fill volume and a maximum of 39 l expansion. Provide a 400 V 3~ 50 Hz supply; the unit ships with cable but no plug.

What installation environment and duty-cycle limits apply to the 250T-H?

Install indoors only, at 5–40 °C ambient, ≥300 lx illuminance, max 2000 m altitude, and not in an ATEX zone. Maintain 50–200 cm wall clearance per side. The unit is IP20, so keep it dry and dust-free. Cooling capacity is rated at 20 °C ambient; higher ambient reduces capacity.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 250T-H Technical Datasheet
Datasheet ·17,8 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF