Peter Huber Kältemaschinenbau Unichiller 250Tw-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 250Tw-H

Peter Huber Kältemaschinenbau Unichiller 250Tw-H — Recirculating chillers.

The Unichiller 250Tw-H is a water-cooled recirculating chiller with a 2 kW heater and a fixed-speed D3 pressure pump, covering -20 to 100 °C. It delivers 18 kW at 0 °C and 6 kW at -20 °C, positioning it as the high-capacity modification in the Unichiller series. It serves externally closed process loops requiring precise temperature control with Pilot ONE electronics.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 250Tw-H Current D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 22 l
Heating capacity 2 kW
Minimum fill volume 15 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 25 °C)
at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW
Cooling water connection G3/4 male
Cooling water consumption 438 л/час (at 15°C, flow -20°C)
at 15°C, flow -10°C: 594 л/час · at 15°C, flow 0°C: 786 l/h · at 15°C, flow 15°C: 852 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and Series Positioning

Performance and Behavior

Installation, Control and Operation

Integration & Operating Notes

Electrical
Three-phase supply must be wired by a qualified electrician

The chiller is delivered with a cable but without a plug, so the site must provide a suitable 400 V 3~ 50 Hz connection. Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%, but not all combinations are allowed. Verify the supply quality before commissioning.

Technical Datasheet, page 2
Cooling & Media
Cooling water inlet must stay between 5 °C and 20 °C

The unit is designed for cooling water intake between 5 °C and 20 °C. If water temperature can drop below the dew point, pipes must be insulated to prevent condensation. A minimum differential pressure of 1 bar is required, and pressure must not exceed 6 bar.

Technical Datasheet, page 2
Mounting
Maintain 50–200 cm wall clearance per side for maintenance access

Free-standing models require a wall clearance of 50 to 200 cm on either side. The unit must be installed indoors with illuminance of at least 300 lx and up to 2000 m altitude. Leveling feet must be activated and parking brakes applied before operation.

Operation Manual, page 25 and page 31
Safety
Process Safety mode releases maximum cooling on OT trigger

In Process Safety mode, the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is critical for exothermic processes where cutting cooling could cause runaway temperatures.

Operation Manual, page 18
Operation
Shut off cooling water supply even for overnight downtime

The cooling water supply must be shut off during shorter downtimes such as overnight to prevent water damage and corrosion. Electrical lines directly below the unit must be protected against liquid ingress from condensation.

Operation Manual, page 28

Selection & Integration Q&A

When should I choose the 250Tw-H over the 110Tw-H or 110T-H?

Choose the 250Tw-H for higher cooling capacity (18 kW at 0 °C vs lower capacities of 110 series) and when water cooling is available. The 110T-H is air-cooled and suited for lower capacity or where cooling water is not available. The 250Tw-H also includes a 2 kW heater.

What are the requirements for the facility cooling water loop?

The cooling water inlet must be between 5 °C and 20 °C, with a minimum differential pressure of 1 bar and maximum pressure of 6 bar. Flow rates vary with load: up to 852 l/h at 15 °C flow. Insulate pipes if below dew point.

Can the chiller be installed in a production area with fluctuating ambient conditions?

The unit is IP20 and must be installed indoors in a dry location protected from water ingress. Ambient temperature must stay between 5 °C and 40 °C. It is not explosion-protected and must not be placed in an ATEX zone. Ensure at least 300 lx illuminance.

What maintenance and service items are required, and what is not included in delivery?

The unit is delivered without a plug; a suitable 400 V 3-phase plug must be sourced. Refrigerant circuit work requires certified contractors. Regular maintenance includes checking cooling water connections for leaks and shutting off water during downtimes. No specific maintenance interval is given in the digests.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 250Tw-H Technical Datasheet
Datasheet ·172,9 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF