Peter Huber Kältemaschinenbau Unichiller 210T-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 210T-H

Peter Huber Kältemaschinenbau Unichiller 210T-H — Recirculating chillers.

The Unichiller 210T-H is an air-cooled, externally closed recirculating chiller with a D3 pressure pump (G1 1/4 male, 210 l/min at zero head) and Pilot ONE controller, rated -20 to 100 °C. It delivers 21 kW at 0 °C and 15 kW at 15 °C, with 2 kW heating and 39 l expansion volume. It serves closed process loops requiring three-phase 400 V supply and IP20 indoor installation.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 210T-H Current D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Heating capacity 2 kW
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 15 °C)
at 0 °C: 21 kW
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Cooling capacity collapses at low temperature

The datasheet rates 21 kW at 0 °C but only 7.5 kW at -20 °C. Processes running near the cold end of the -20 to 100 °C range must be sized against the derated capacity, not the 0 °C figure, or the unit will be undersized.

Unichiller 210T-H Datasheet, Specifications
Cooling & Media
Match external loop pressure drop to pump curve

The D3 pump delivers 210 l/min at zero head but only 31 l/min at 4.5 bar. The external circuit resistance must be calculated and compared with the pump curve; a high-pressure-drop loop will starve flow. Models with 'P' in the name are the ones intended for high pressure drops.

Unichiller 210T-H Datasheet, Specifications; Unichiller Operation Manual, Function Description
Electrical
Supply tolerances must not combine adversely

Voltage tolerance is ±5% and frequency tolerance ±2%, but the manual states they must not be combined in opposite directions. Site power quality must be verified before connection; the unit is delivered with cable but without a plug for three-phase devices below 63 A.

Unichiller 210T-H Datasheet, Installation; Unichiller Operation Manual, Commissioning
Mounting
Indoor IP20 location with wall clearance

The unit is IP20 and must be installed indoors, protected from water and dust, at illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance; leveling feet or parking brakes must be activated before startup.

Unichiller Operation Manual, Setup Mode
Safety
Process Safety mode changes overtemperature response

In Process Safety mode the controller releases maximum cooling capacity when the adjustable overtemperature trigger is reached, instead of switching off all poles. For exothermic processes this prevents runaway; for other processes the standard cutoff behavior may be preferred. The mode is selected via the Pilot ONE.

Unichiller Operation Manual, Normal Operation
Maintenance
Refrigerant circuit work restricted to approved contractors

Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-449A (GHS H280), and refrigerant charge versus room size must be checked at installation to stay within the limit per m³ of ambient air.

Unichiller Operation Manual, Maintenance; Unichiller 210T-H Datasheet
Electrical
EMC Class A may disturb sensitive electronics nearby

The equipment is classified EMC Class A Group 1 to EN55011, so it may cause radio interference in residential areas. Placement near sensitive measurement or control electronics should account for this, and appropriate installation measures may be needed.

Unichiller 210T-H Datasheet, Installation

Selection & Integration Q&A

When should I choose the Unichiller 210T-H over the 110T or 110Tw siblings?

Pick the 210T-H when the process needs up to 21 kW at 0 °C and a 39 l expansion volume in a closed loop. The 110T/110T-H and 110Tw/110Tw-H are smaller-capacity units; the Tw variants are quieter (65 dB(A) vs 74 dB(A)) but do not match the 210T-H cooling capacity.

What hydraulic and electrical infrastructure must be provided for this chiller?

Provide a 400 V 3~ 50 Hz supply with voltage/frequency tolerances not combined adversely; three-phase units below 63 A come with cable but no plug. The external loop must mate with the G1 1/4 male pump connection, hold at least 14 l fill volume, and its pressure drop must be checked against the pump curve (210 l/min at 0 bar, 31 l/min at 4.5 bar).

What are the installation environment and duty-cycle limits from the manual?

Install indoors only, IP20, at 5–40 °C ambient, illuminance ≥300 lx, altitude ≤2000 m, with 50–200 cm wall clearance per side. Not permitted in ATEX zones. Leveling feet/parking brakes must be set before operation. Cooling capacity may fall above 20 °C room temperature.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes cable but no plug for three-phase units below 63 A. Refrigerant circuit work must be done by approved refrigeration contractors; R-449A charge and room size must be checked. The Pilot ONE offers Ethernet, USB and RS232; an external Pt100 sensor can be connected. No consumables or spare parts are listed in the provided documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 210T-H Datasheet
Datasheet ·17,8 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF