Peter Huber Kältemaschinenbau Unichiller 180T-H
Peter Huber Kältemaschinenbau Unichiller 180T-H — Recirculating chillers.
The Unichiller 180T-H is an air-cooled, externally closed recirculating chiller with a pressure pump (D3, non-variable speed) and Pilot ONE controller, covering -20 to 100 °C. It is the high-capacity 180T-H modification in the Unichiller series, distinguished by 18 kW cooling at 15/0 °C falling to 6 kW at -20 °C. It serves industrial process cooling loops where a closed hydraulic circuit and three-phase power are available.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 180T-H Current | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Air-cooled refrigeration circuit using R-449A (GWP 1397); no cooling-water connection required, but condenser airflow and room ventilation are mandatory.
- Externally closed hydraulic circuit only; pump connection G1 1/4 male, pressure pump D3 with fixed speed (pump-speed-adjustable: no).
- Compared with the Unichiller 110T/110T-H siblings (74 dB(A)) and 110Tw/110Tw-H (65 dB(A)), the 180T-H is the larger-capacity frame; the 'T' denotes the air-cooled tower configuration and 'H' the heating variant (2 kW heating capacity).
- Controller: Pilot ONE; interfaces Ethernet, USB host/device, RS232; external Pt100 sensor input.
Behavior under load and media
- Cooling capacity is strongly temperature-dependent: 18 kW at 15 °C and 0 °C, 11 kW at -10 °C, 6 kW at -20 °C. Size the loop for the lowest required operating temperature, not the nominal rating.
- Pump curve: 210 l/min at zero head, 77 l/min at 4.0 bar; maximum delivery pressure 4.7 bar. High-pressure-drop loops must be checked against this curve; models with 'P' in the name are the high-pressure-drop alternative.
- Fluid charge: minimum filling 14 l, expansion volume 39 l; underfilling risks cavitation, and the expansion volume caps total loop volume.
- Overtemperature protection adjustable per DIN 12876; safety class III/FL. Process Safety mode releases maximum cooling at the OT trigger instead of switching off all poles.
Installation, control and operation
- 400 V 3~ 50 Hz supply, cable supplied without plug; mains tolerances ±5 % voltage and ±2 % frequency, not to be combined unfavorably.
- IP20, EMC class A group 1: indoor, dry, dust-free installation only; not in ATEX zones; illuminance at least 300 lx; altitude up to 2000 m.
- Wall clearance 50–200 cm per side for maintenance; leveling feet/parking brakes must be set before start-up.
- Power-failure response configurable via Pilot ONE (OFF/Standby, ON, Power Failure Auto).
Integration & Operating Notes
The datasheet gives 18 kW at 15 °C and 0 °C but only 11 kW at -10 °C and 6 kW at -20 °C. A loop specified from the 18 kW figure will lose temperature control at low setpoints; the refrigeration circuit must be selected against the coldest required operating point plus margin.
The D3 pump delivers 210 l/min at zero head and 77 l/min at 4.0 bar (max 4.7 bar), and speed is not adjustable. A high-resistance process loop will reduce flow below the required rate; check the system curve against the pump curve before ordering, or select a 'P' model for high-pressure-drop applications.
The unit is delivered with cable but without a plug; the customer must supply a suitable mains connection, breaker and earthing by a qualified electrician. Voltage tolerance is ±5 % and frequency ±2 %, and the unfavorable combination (-5 % voltage with +2 % frequency) is not permitted.
A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. The unit is IP20 and must be installed indoors in a dry, dust-free location at illuminance of at least 300 lx and up to 2000 m altitude; it must not be installed or started inside an ATEX zone.
Cooling capacity data are valid at 20 °C room temperature and drop as ambient temperature rises; the permitted ambient range is 5 to 40 °C. The installation site must provide sufficient air flow around the condenser, and refrigerant charge versus room size must be checked against the refrigerant limit per m³.
The unit is designed for externally closed applications only. Minimum filling capacity is 14 l and expansion volume is 39 l; underfilling causes pump cavitation and poor control, while the expansion volume limits the total loop volume that can be accommodated.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles; the OT trigger must be set for the fluid in use.
Work on the coolant circuit must only be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-449A with GWP 1397, so leak monitoring and service planning should account for refrigerant regulations; the rating plate and datasheet state the charge.
Parking brakes must be activated at the casters (if any) and/or leveling feet unscrewed/activated before the unit is put into operation, to prevent movement and crushing injuries. Pump connections must be counterheld and the maximum tightening torques not exceeded during hose installation.
Selection & Integration Q&A
Choose the 180T-H when the loop needs up to 18 kW cooling at 0–15 °C and 2 kW heating, with a fixed-speed D3 pump. The 110T/110T-H and 110Tw/110Tw-H are lower-capacity frames; the 'w' variants are quieter (65 vs 74 dB(A)) but not higher-capacity. For high-pressure-drop loops, a 'P' model is the correct choice instead.
A 400 V 3~ 50 Hz supply with a suitable plug, breaker and earthing by a qualified electrician (cable supplied without plug), within ±5 % voltage and ±2 % frequency and not combined unfavorably. Hydraulically, G1 1/4 male pump connections require matching hoses/adapters, counterheld at the maximum tightening torque, in an externally closed circuit charged with at least 14 l.
Indoor, dry, dust-free site only (IP20), 5–40 °C ambient, illuminance at least 300 lx, altitude up to 2000 m, no ATEX zone. Allow 50–200 cm wall clearance per side for maintenance and sufficient condenser airflow; cooling capacity is rated at 20 °C room temperature and derates as ambient rises. Secure leveling feet/parking brakes before start-up.
The base delivery excludes the mains plug and process hoses/adapters (G1 1/4 male). Refrigerant-circuit service must be performed by approved refrigeration contractors; the R-449A charge (GWP 1397) and room size must be checked at installation. The Pilot ONE provides Ethernet, USB host/device and RS232 for remote monitoring; an external Pt100 sensor can be connected for process control.