Peter Huber Kältemaschinenbau Unichiller 300Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 300Tw

Peter Huber Kältemaschinenbau Unichiller 300Tw — Recirculating chillers with Noise level 65 dB.

The Unichiller 300Tw is a water-cooled recirculating chiller with a Pilot ONE controller, rated for -20 to 40 °C and a 460 V 3~ 60 Hz supply at 23 A. It is the quiet 65 dB(A) variant in the series, distinguished from the 110T siblings by capacity rather than by noise class. It serves externally closed process loops requiring up to 30 kW of cooling at 15 °C water inlet.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 300Tw Current D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Expansion volume 22 l
Minimum fill volume 15 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 385 kg
Electrical, Power & Drive Specifications
Current consumption 23 A (max)
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-449A (A1, H280) (1st stage)
Refrigerant quantity 3 kg (1st stage)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The 300Tw is a free-standing, water-cooled chiller with a 22 l expansion volume and a 15 l minimum fill, connected to the process via a G1 1/4 AG male pump connection and to the facility water loop via G3/4 male cooling-water connections. Its pump is a fixed-speed D3 type (pump speed not adjustable). Within the series, the 110Tw and 110Tw-H share the same 65 dB(A) noise class, while the 110T and 110T-H are rated at 74 dB(A); the 300Tw is therefore selected for its capacity and its low-noise water-cooled architecture rather than as a noise-optimized derivative of the 110 frame. The refrigerant is R-449A (A1, H280) with a 3 kg first-stage charge.

Behavior under load and media

Cooling capacity is rating-basis dependent: 30 kW at 15 °C water inlet falling to 8 kW at -20 °C, valid only at 20 °C room temperature, 15 °C cooling-water inlet and 1 bar differential pressure between cooling-water inlet and outlet. The process temperature range is -20 to 40 °C, while the cooling-water inlet must remain between 5 and 20 °C. The cooling-water circuit materials (copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM) constrain water quality. The unit is designed for externally closed applications only.

Installation, control and operation

The Pilot ONE controller provides Ethernet, USB host and device, and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto. In Process Safety mode, reaching the overtemperature trigger releases maximum cooling capacity instead of switching off all poles. The unit is IP20, EMC Class A Group 1, safety class I/NFL, and must be installed indoors at 5–40 °C ambient with at least 300 lx illuminance and up to 2000 m altitude.

Integration & Operating Notes

Electrical
Supply must be 460 V 3~ 60 Hz with UL 489 branch protection

The 23 A maximum current requires 3x25 A fusing and an external branch circuit protection device according to UL 489. Three-phase devices under 63 A arrive with cable but without a plug, so the customer must supply and fit the plug. Voltage and frequency tolerances of ±5% and ±2% must not combine in the same direction.

Unichiller 300Tw Technical Datasheet, page 2
Cooling & Media
Facility water loop must deliver 1–6 bar with ≥1 bar differential

Cooling water inlet temperature must stay between 5 and 20 °C; below the condensation point, pipes must be insulated. Rated capacity assumes 15 °C inlet and 1 bar differential, so deviations reduce available cooling. The cooling-water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, restricting water treatment choices.

Unichiller 300Tw Technical Datasheet, pages 1–2
Process Limits
Externally closed circuits only; no ATEX zone installation

The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Refrigerant charge and room size must be checked at installation to avoid exceeding the refrigerant limit per m³ of ambient air. The refrigerant is A1 with H280 hazard statement.

Unichiller Operation Manual, pages 13, 15, 34

Selection & Integration Q&A

When should I choose the Unichiller 300Tw over the 110Tw or 110T siblings?

Choose the 300Tw for higher cooling demand in an externally closed loop; it shares the 65 dB(A) water-cooled noise class with the 110Tw but is a larger frame. The 110T and 110T-H are rated 74 dB(A), so pick those only if the higher noise level is acceptable.

What facility water and electrical infrastructure must be in place before the 300Tw can be commissioned?

A 460 V 3~ 60 Hz supply with 3x25 A fusing and a UL 489 branch breaker, plus a customer-fitted plug on the delivered cable. The cooling-water loop must provide 5–20 °C water at 1–6 bar with at least 1 bar differential pressure through G3/4 male connections.

What mounting and ambient conditions does the manual impose on this chiller?

Indoor installation only, ambient 5–40 °C, illuminance at least 300 lx, altitude up to 2000 m, and 50–200 cm clearance per side for maintenance. Leveling feet and caster brakes must be set before startup, and the unit must not be placed in an ATEX zone.

What is not included in base delivery and what service obligations apply?

The three-phase cable is supplied without a plug, so the customer must fit one. Refrigerant-circuit work is restricted to approved refrigeration contractors. The cooling water must be shut off during downtimes, and the R-449A charge (3 kg, 4.2 t CO2e) carries leak-reporting obligations.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 300Tw Technical Datasheet
Datasheet ·18,4 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF