Peter Huber Kältemaschinenbau Unichiller 250T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 250T

Peter Huber Kältemaschinenbau Unichiller 250T — Recirculating chillers.

The Unichiller 250T is an air-cooled, externally closed recirculating chiller with a 6–18 kW cooling capacity window across −20 to +40 °C, built around a fixed-speed D3 pressure pump and Pilot ONE controller. It is the larger-capacity member of the Unichiller T series, distinguished from the 110T siblings by its higher heat-rejection envelope rather than by any change in hydraulic architecture.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 250T Current D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 25 °C)
at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior across the operating envelope

Installation, control and operation

Integration & Operating Notes

Mounting
Plan 50–200 cm clearance per side and level the unit before start

Air-cooled rejection means restricted airflow directly reduces capacity and can overheat the compressor. The manual requires 50 to 200 cm wall clearance on either side for maintenance, and leveling feet or caster brakes must be engaged before power-up to prevent the unit moving.

Unichiller Operation Manual, Installation
Electrical
Do not combine −5% voltage with +2% frequency on the supply

The drive and compressor tolerate ±5% voltage and ±2% frequency individually, but the specific pairing of −5% voltage and +2% frequency is prohibited. Verify the actual site supply combination before commissioning, since an out-of-tolerance combination can damage the compressor or pump.

Unichiller 250T Technical Data, Installation
Electrical
Three-phase unit arrives with cable but no plug

Because the current draw is below 63 A, the 400 V 3~ 50 Hz unit is delivered with a cable only. The installer must provide a suitable plug or hard-wired termination and a matching protective device on site.

Unichiller 250T Technical Data, Installation
Process Limits
External circuit must be closed and sized for 14–39 l

The unit is intended only for externally closed applications. Minimum fill is 14 l and expansion volume is 39 l; underfilling causes pump cavitation and poor control, while an open circuit risks evaporation and overflow of the atmospheric expansion tank.

Unichiller 250T Technical Data, Operation; Unichiller Operation Manual, Function Description
Environment
Indoor only, 5–40 °C ambient, IP20 — no washdown

Installation is restricted to indoors with illuminance of at least 300 lx and altitude up to 2000 m. IP20 offers no water protection, and operation outside the 5–40 °C ambient window impairs cooling or damages components. The unit is not explosion-protected and must not be placed in an ATEX zone.

Unichiller 250T Technical Data, Installation; Unichiller Operation Manual, Installation
Maintenance
Refrigerant circuit work is restricted to approved contractors

Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. R-449A is A1 with H280 pressurised-gas hazard and GWP 1397, so leak detection, handling and disposal must follow those precautions and be reflected in service planning.

Unichiller Operation Manual, Maintenance; Unichiller 250T Technical Data, Safety

Selection & Integration Q&A

When should I choose the Unichiller 250T instead of a 110T or 110Tw sibling?

Pick the 250T when the heat load needs the 6–18 kW window across −20 to +40 °C. The 110T/110Tw siblings are lower-capacity; the Tw variants differ in noise level (65 vs 74 dB(A)). If the loop has high pressure drop, a 'P' model is the correct choice, not this standard T variant.

What must I provide on site for power and for the external hydraulic circuit?

A 400 V 3~ 50 Hz supply within ±5% voltage and ±2% frequency (the −5%/+2% combination is prohibited), with a plug or termination since the unit ships cable-only. The external circuit must be closed, charged to at least 14 l with 39 l expansion allowance, and fitted to G1 1/4 male threads — only one hose coupling is included.

What mounting and duty-cycle limits does the manual impose?

Indoors only, 5–40 °C ambient, ≥300 lx illuminance, up to 2000 m altitude, with 50–200 cm clearance per side for airflow and maintenance. Leveling feet or caster brakes must be engaged before start. The unit is not ATEX-rated and must not be installed in a hazardous zone.

What maintenance and consumables are needed beyond the base delivery?

Refrigerant-circuit service must be done by approved refrigeration contractors; R-449A (GWP 1397, H280) handling and leak checks are part of that schedule. The base delivery includes only one G1 1/4 hose coupling, so additional hoses, fittings and heat-transfer fluid must be sourced separately. Cooling-water shutoff applies only to water-cooled variants, not this air-cooled unit.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 250T Technical Data
Datasheet ·17,7 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF