Peter Huber Kältemaschinenbau Unichiller 260Tw-H
Peter Huber Kältemaschinenbau Unichiller 260Tw-H — Recirculating chillers.
The Unichiller 260Tw-H is a water-cooled recirculating chiller with a 2 kW heater and a fixed-speed D3 pressure pump, covering -20 to 100 °C. It is the high-capacity Tw-H modification in the Unichiller series, distinguished by its 400 V three-phase supply and G1 1/4 pump connection. It serves externally closed process loops requiring temperature control with cooling water available at 5–20 °C.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 260Tw-H Current | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 22 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 15 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The Unichiller 260Tw-H is a water-cooled (W) recirculating chiller with heater (H) in the Unichiller series. Unlike the smaller 110T/110Tw siblings, this model is supplied from a 400 V three-phase 50 Hz feed and uses a fixed-speed D3 pressure pump with G1 1/4 male pump connections. The cooling water circuit connects via G3/4 male fittings. The unit is rated IP20 and safety class III / FL with adjustable overtemperature protection to DIN 12876. Refrigerant is R-449A (A1, H280, GWP 1397).
Working range and media behavior
The temperature range is -20 to 100 °C. Cooling water inlet must be 5–20 °C; rated cooling power is quoted at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure. As cooling water temperature rises, cooling capacity drops and required flow may increase. The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so water quality must be compatible. Minimum fill volume is 15 l and expansion volume is 22 l.
Installation and control
Installation is indoors only, at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance. The unit is not explosion-protected and must not be installed in an ATEX zone. Three-phase devices below 63 A are delivered with cable but without a plug. The Pilot ONE controller provides Ethernet, USB host/device and RS232 interfaces, a Pt100 external sensor connection, and configurable power-failure response (OFF/Standby, ON, Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.
Integration & Operating Notes
The 400 V 3~ 50 Hz supply is delivered with cable but no plug for currents below 63 A, so a suitable plug and protection must be provided on site. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.
The cooling water supply must provide at least 1 bar differential pressure and must not exceed 6 bar. Inlet temperature must be between 5 and 20 °C; below the condensation point, pipes must be insulated. Higher cooling water temperatures reduce capacity and may require increased flow.
Install indoors at 5–40 °C ambient, at least 300 lx, up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance. Before start-up, activate parking brakes and/or unscrew leveling feet. Electrical lines directly below the unit must be protected against liquid ingress from condensation.
For exothermic processes, configure Process Safety so that maximum cooling capacity is released when the overtemperature trigger value is reached, instead of switching off all poles. The power-failure response can be set to OFF/Standby, ON, or Power Failure Auto via the Pilot ONE.
Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Check refrigerant charge against room size at installation to avoid exceeding the limit per m³ of ambient air. Shut off cooling water even for short downtimes such as overnight.
The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Models with 'P' in the name are the ones suited to high pressure drop; this model uses a fixed-speed D3 pump.
Selection & Integration Q&A
Choose the 260Tw-H when you need a 400 V three-phase feed, a 2 kW heater and the higher capacity implied by the 260 size code, with a fixed-speed D3 pump. The 110T/110Tw siblings are smaller and differ in noise level (74 vs 65 dB(A)); select them when their capacity and single-phase supply match the load.
Provide a 400 V 3~ 50 Hz supply with a site-fitted plug (cable supplied, no plug below 63 A), cooling water at 5–20 °C and 1–6 bar differential, G3/4 male cooling water fittings, and G1 1/4 male pump connections with compatible hoses. The external loop must hold at least 15 l fill and fit within 22 l expansion.
Install indoors only at 5–40 °C ambient, at least 300 lx, up to 2000 m altitude, with 50–200 cm wall clearance per side. Activate parking brakes and leveling feet before start-up. Shut off cooling water even overnight. The unit is not ATEX-rated and is limited to externally closed applications.
The base delivery includes cable but no plug for three-phase units below 63 A. Refrigerant circuit work requires approved contractors. No consumables or spare parts are listed in the digests; plan for compatible cooling water treatment and hose/adapters for G1 1/4 and G3/4 connections separately.