Peter Huber Kältemaschinenbau Unichiller 180T-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 180T-H

Peter Huber Kältemaschinenbau Unichiller 180T-H — Recirculating chillers.

The Unichiller 180T-H is an air-cooled, externally closed recirculating chiller with a pressure pump (D3, non-variable speed) and Pilot ONE controller, covering -20 to 100 °C. It is the high-capacity 180T-H modification in the Unichiller series, distinguished by 18 kW cooling at 15/0 °C falling to 6 kW at -20 °C. It serves industrial process cooling loops where a closed hydraulic circuit and three-phase power are available.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 180T-H Current D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Heating capacity 2 kW
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...100 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Size cooling capacity at the lowest loop temperature

The datasheet gives 18 kW at 15 °C and 0 °C but only 11 kW at -10 °C and 6 kW at -20 °C. A loop specified from the 18 kW figure will lose temperature control at low setpoints; the refrigeration circuit must be selected against the coldest required operating point plus margin.

Unichiller 180T-H Technical Data, page 1
Cooling & Media
Verify loop pressure drop against the fixed-speed pump curve

The D3 pump delivers 210 l/min at zero head and 77 l/min at 4.0 bar (max 4.7 bar), and speed is not adjustable. A high-resistance process loop will reduce flow below the required rate; check the system curve against the pump curve before ordering, or select a 'P' model for high-pressure-drop applications.

Unichiller 180T-H Technical Data, page 1; Operation Manual, Function Description
Electrical
Provide a 400 V 3~ 50 Hz supply with plug and protection

The unit is delivered with cable but without a plug; the customer must supply a suitable mains connection, breaker and earthing by a qualified electrician. Voltage tolerance is ±5 % and frequency ±2 %, and the unfavorable combination (-5 % voltage with +2 % frequency) is not permitted.

Unichiller 180T-H Technical Data, page 2
Mounting
Respect wall clearance and indoor-only siting

A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. The unit is IP20 and must be installed indoors in a dry, dust-free location at illuminance of at least 300 lx and up to 2000 m altitude; it must not be installed or started inside an ATEX zone.

Unichiller Operation Manual, pages 13 and 25
Cooling & Media
Air-cooled condenser needs room ventilation and ambient derating

Cooling capacity data are valid at 20 °C room temperature and drop as ambient temperature rises; the permitted ambient range is 5 to 40 °C. The installation site must provide sufficient air flow around the condenser, and refrigerant charge versus room size must be checked against the refrigerant limit per m³.

Unichiller 180T-H Technical Data, page 2; Operation Manual, page 15
Process Limits
Closed-loop only; charge between 14 l and expansion limit

The unit is designed for externally closed applications only. Minimum filling capacity is 14 l and expansion volume is 39 l; underfilling causes pump cavitation and poor control, while the expansion volume limits the total loop volume that can be accommodated.

Unichiller 180T-H Technical Data, page 1; Operation Manual, page 34
Control & I/O
Configure power-failure response for the process risk

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles; the OT trigger must be set for the fluid in use.

Unichiller Operation Manual, pages 18–19
Maintenance
Refrigerant circuit work requires certified contractors

Work on the coolant circuit must only be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-449A with GWP 1397, so leak monitoring and service planning should account for refrigerant regulations; the rating plate and datasheet state the charge.

Unichiller Operation Manual, page 17; Technical Data, page 1
Mounting
Secure the unit before start-up

Parking brakes must be activated at the casters (if any) and/or leveling feet unscrewed/activated before the unit is put into operation, to prevent movement and crushing injuries. Pump connections must be counterheld and the maximum tightening torques not exceeded during hose installation.

Unichiller Operation Manual, pages 28 and 31

Selection & Integration Q&A

When should I choose the Unichiller 180T-H rather than a 110T or 110Tw sibling?

Choose the 180T-H when the loop needs up to 18 kW cooling at 0–15 °C and 2 kW heating, with a fixed-speed D3 pump. The 110T/110T-H and 110Tw/110Tw-H are lower-capacity frames; the 'w' variants are quieter (65 vs 74 dB(A)) but not higher-capacity. For high-pressure-drop loops, a 'P' model is the correct choice instead.

What must be provided on the plant side to connect and power the 180T-H?

A 400 V 3~ 50 Hz supply with a suitable plug, breaker and earthing by a qualified electrician (cable supplied without plug), within ±5 % voltage and ±2 % frequency and not combined unfavorably. Hydraulically, G1 1/4 male pump connections require matching hoses/adapters, counterheld at the maximum tightening torque, in an externally closed circuit charged with at least 14 l.

What installation and duty-cycle limits apply to the 180T-H?

Indoor, dry, dust-free site only (IP20), 5–40 °C ambient, illuminance at least 300 lx, altitude up to 2000 m, no ATEX zone. Allow 50–200 cm wall clearance per side for maintenance and sufficient condenser airflow; cooling capacity is rated at 20 °C room temperature and derates as ambient rises. Secure leveling feet/parking brakes before start-up.

What maintenance and accessories are needed beyond the base delivery?

The base delivery excludes the mains plug and process hoses/adapters (G1 1/4 male). Refrigerant-circuit service must be performed by approved refrigeration contractors; the R-449A charge (GWP 1397) and room size must be checked at installation. The Pilot ONE provides Ethernet, USB host/device and RS232 for remote monitoring; an external Pt100 sensor can be connected for process control.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 180T-H Technical Data
Datasheet ·17,8 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF