Peter Huber Kältemaschinenbau Unichiller 300Tw
Peter Huber Kältemaschinenbau Unichiller 300Tw — Recirculating chillers with Noise level 65 dB.
The Unichiller 300Tw is a water-cooled recirculating chiller with a Pilot ONE controller, rated for -20 to 40 °C and a 460 V 3~ 60 Hz supply at 23 A. It is the quiet 65 dB(A) variant in the series, distinguished from the 110T siblings by capacity rather than by noise class. It serves externally closed process loops requiring up to 30 kW of cooling at 15 °C water inlet.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 300Tw Current | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Noise level | 65 dB(A) |
| Expansion volume | 22 l |
| Minimum fill volume | 15 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 385 kg |
| Current consumption | 23 A (max) |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-449A (A1, H280) (1st stage) |
| Refrigerant quantity | 3 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The 300Tw is a free-standing, water-cooled chiller with a 22 l expansion volume and a 15 l minimum fill, connected to the process via a G1 1/4 AG male pump connection and to the facility water loop via G3/4 male cooling-water connections. Its pump is a fixed-speed D3 type (pump speed not adjustable). Within the series, the 110Tw and 110Tw-H share the same 65 dB(A) noise class, while the 110T and 110T-H are rated at 74 dB(A); the 300Tw is therefore selected for its capacity and its low-noise water-cooled architecture rather than as a noise-optimized derivative of the 110 frame. The refrigerant is R-449A (A1, H280) with a 3 kg first-stage charge.
Behavior under load and media
Cooling capacity is rating-basis dependent: 30 kW at 15 °C water inlet falling to 8 kW at -20 °C, valid only at 20 °C room temperature, 15 °C cooling-water inlet and 1 bar differential pressure between cooling-water inlet and outlet. The process temperature range is -20 to 40 °C, while the cooling-water inlet must remain between 5 and 20 °C. The cooling-water circuit materials (copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM) constrain water quality. The unit is designed for externally closed applications only.
Installation, control and operation
The Pilot ONE controller provides Ethernet, USB host and device, and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto. In Process Safety mode, reaching the overtemperature trigger releases maximum cooling capacity instead of switching off all poles. The unit is IP20, EMC Class A Group 1, safety class I/NFL, and must be installed indoors at 5–40 °C ambient with at least 300 lx illuminance and up to 2000 m altitude.
Integration & Operating Notes
The 23 A maximum current requires 3x25 A fusing and an external branch circuit protection device according to UL 489. Three-phase devices under 63 A arrive with cable but without a plug, so the customer must supply and fit the plug. Voltage and frequency tolerances of ±5% and ±2% must not combine in the same direction.
Cooling water inlet temperature must stay between 5 and 20 °C; below the condensation point, pipes must be insulated. Rated capacity assumes 15 °C inlet and 1 bar differential, so deviations reduce available cooling. The cooling-water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, restricting water treatment choices.
The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Refrigerant charge and room size must be checked at installation to avoid exceeding the refrigerant limit per m³ of ambient air. The refrigerant is A1 with H280 hazard statement.
Selection & Integration Q&A
Choose the 300Tw for higher cooling demand in an externally closed loop; it shares the 65 dB(A) water-cooled noise class with the 110Tw but is a larger frame. The 110T and 110T-H are rated 74 dB(A), so pick those only if the higher noise level is acceptable.
A 460 V 3~ 60 Hz supply with 3x25 A fusing and a UL 489 branch breaker, plus a customer-fitted plug on the delivered cable. The cooling-water loop must provide 5–20 °C water at 1–6 bar with at least 1 bar differential pressure through G3/4 male connections.
Indoor installation only, ambient 5–40 °C, illuminance at least 300 lx, altitude up to 2000 m, and 50–200 cm clearance per side for maintenance. Leveling feet and caster brakes must be set before startup, and the unit must not be placed in an ATEX zone.
The three-phase cable is supplied without a plug, so the customer must fit one. Refrigerant-circuit work is restricted to approved refrigeration contractors. The cooling water must be shut off during downtimes, and the R-449A charge (3 kg, 4.2 t CO2e) carries leak-reporting obligations.