Peter Huber Kältemaschinenbau Unichiller GL 200w
Peter Huber Kältemaschinenbau Unichiller GL 200w — Recirculating chillers.
The Unichiller GL 200w is a water-cooled recirculating chiller with a natural R-744 refrigerant circuit, rated 20 kW at 19 °C and operating from -20 to 40 °C. It is the 200-series GL modification in the Unichiller line, distinguished by a 460 V three-phase supply and G3/4 cooling-water connections. It serves externally closed process loops requiring stable cooling with Pilot ONE control.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller GL 200w Current | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 30 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 20 kW (at 19 °C) |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled condenser with natural refrigerant R-744 (GWP 1), avoiding synthetic high-GWP refrigerants.
- Fixed-speed pressure pump with G1 1/4 AG male process connections; pump speed is not adjustable.
- 30 l expansion volume and Pt100 external sensor input for process-side temperature feedback.
- Within the Unichiller series, this GL 200w is the 460 V/60 Hz variant; sibling 110T models are air-cooled (noise 74 dB(A)) or water-cooled 110Tw (65 dB(A)) and are not interchangeable with this unit's electrical or hydraulic configuration.
Behavior and operating envelope
- Temperature range -20 to 40 °C; rated cooling capacity 20 kW at 19 °C, with datasheet output valid at 20 °C room, 15 °C cooling-water inlet and 1 bar differential pressure.
- Cooling-water circuit requires 1 bar minimum differential pressure and tolerates 6 bar maximum; intake temperature must be 5–20 °C, and internal cooling-water pipes need insulation below the condensation point.
- Ambient operating range 5–40 °C; IP20 enclosure restricts installation to dry indoor locations.
Control, installation and operation
- Pilot ONE controller with Ethernet, USB host/device and RS232 interfaces; power-failure response configurable as OFF/Standby, ON or Power Failure Auto.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles.
- Three-phase supply 460 V 3~ 60 Hz with ±5% voltage tolerance only alongside ±2% frequency tolerance; external UL 489 branch protection required; cable supplied without plug for currents below 63 A.
- Free-standing installation requires 50–200 cm wall clearance per side, leveling feet or parking brakes engaged before start-up, and cooling water shut off during downtimes.
Integration & Operating Notes
The site must provide 460 V 3~ 60 Hz; voltage tolerance of ±5% is permitted only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed. Verify the supply before ordering, since a transformer or a different model may be needed.
External branch circuit protection according to UL 489 is required. Three-phase devices drawing less than 63 A are supplied with cable but without a plug, so the installer must provide a suitable plug or hard-wired connection.
The cooling-water circuit needs at least 1 bar differential pressure and must not exceed 6 bar. Intake temperature must stay between 5 °C and 20 °C; below the condensation point the internal cooling-water pipes must be insulated to prevent condensation.
IP20 protection and the manual require a dry indoor site with at least 300 lx illuminance and altitude up to 2000 m. Free-standing models need 50–200 cm wall clearance per side for maintenance, and electrical lines directly below the unit must be protected against liquid ingress from condensation.
Parking brakes must be activated at the casters and/or leveling feet unscrewed before the unit is put into operation. Shut off the cooling water supply even for short downtimes such as overnight to prevent water damage and corrosion.
The Pilot ONE allows the power-failure response to be set as OFF/Standby, ON or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit is classified to DIN 12876 with identification depending on whether the thermal fluid is combustible, so confirm the fluid before service.
The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Models with 'P' in the model name are the ones suited to high pressure-drop applications, not this GL variant.
Selection & Integration Q&A
Choose the GL 200w for a 460 V/60 Hz site needing 20 kW at 19 °C with water cooling and R-744. The 110T is air-cooled at 74 dB(A); the 110Tw is water-cooled at 65 dB(A). Select by supply voltage, cooling-water availability and noise limit.
Cooling water at 5–20 °C intake, 1 bar minimum differential pressure and 6 bar maximum, with G3/4 male connections. The process loop must be externally closed and connect to G1 1/4 AG male pump ports; the pump is fixed-speed.
Install indoors only, dry, at 5–40 °C ambient, at least 300 lx, up to 2000 m altitude, with 50–200 cm side clearance. IP20 rules out wet areas; no ATEX zone. Shut off cooling water even overnight and secure casters or leveling feet before start-up.
No plug is supplied for three-phase units below 63 A; the installer provides a plug or hard-wired connection plus UL 489 branch protection. Refrigerant-circuit service requires approved refrigeration contractors; confirm the DIN 12876 fluid class before maintenance.