Peter Huber Kältemaschinenbau Unichiller 180T
Peter Huber Kältemaschinenbau Unichiller 180T — Recirculating chillers.
The Unichiller 180T is a 400 V three-phase recirculating chiller with a -20 to 40 °C window and 18 kW at 0 °C, dropping to 6 kW at -20 °C. It is the larger-capacity member of the Unichiller T series, distinguished from the 110T siblings by its 18 kW class rather than 74/65 dB(A) noise variants. It serves externally closed process loops requiring a G1 1/4 male pump connection and at least 14 l fill.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 180T Current | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 533 kg |
| Current consumption | 23 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 15 °C) at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The 180T is a free-standing, 533 kg, 905 x 1582 x 1900 mm recirculating chiller with a D3 fixed-speed pump (no speed adjustment) and G1 1/4 AG male connections.
- Within the Unichiller T series, the 110T and 110T-H are the 74 dB(A) variants; the 110Tw and 110Tw-H are the 65 dB(A) variants. The 180T is the higher-capacity modification, rated 18 kW at 0 °C, and is not a noise-optimised variant.
- The refrigerant is R-449A (A1, H280) with a 5.75 kg charge and 8.0 t CO2 equivalent, which places it under F-gas leak-check obligations.
Behavior across the temperature window
- Cooling capacity is 18 kW at 0 °C, 15 kW at 15 °C, 11 kW at -10 °C and 6 kW at -20 °C; the cold end of the -20 to 40 °C range therefore carries roughly one-third of the 0 °C rating.
- Rated output is valid at 20 °C room temperature; capacity may fall as ambient rises toward the 40 °C limit.
- The unit is designed for externally closed applications only; models with “P” in the name are the ones suited to high pressure drop loops, which the 180T is not.
Installation, control and operation
- Supply is 400 V 3~ 50 Hz with 23 A maximum current; three-phase units below 63 A ship with cable but without a plug, so the site must provide the connection.
- Voltage and frequency tolerances must be met simultaneously; a -5% voltage with +2% frequency combination is not permitted.
- The Pilot ONE controller provides Ethernet, USB host and device, and RS232 interfaces, a Pt100 external sensor input, and configurable power-failure response (OFF/Standby, ON, Power Failure Auto).
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
- IP20 protection and EMC class A group 1 restrict installation to indoor industrial environments with 5 to 40 °C ambient and at least 300 lx illuminance.
Integration & Operating Notes
The 23 A maximum current requires cable and breaker sizing at the installation site, and because three-phase devices below 63 A are delivered with cable but without a plug, the customer must provide the mating connection before commissioning.
Voltage and frequency tolerances must be satisfied simultaneously; the datasheet explicitly disallows a -5% voltage with +2% frequency combination, so supply quality should be checked against both limits together rather than independently.
Free-standing models require this clearance on either side for service access, and the 533 kg weight plus 905 x 1582 x 1900 mm footprint must be planned for floor loading and rigging before the unit is moved into place.
The unit may only be used indoors with illuminance of at least 300 lx and at altitudes up to 2000 m; it must not be installed or started inside an ATEX zone because it is not explosion-protected.
The unit is designed for externally closed applications, with a minimum filling capacity of 14 l and 39 l expansion volume; the loop must be designed to stay within these volumes and the G1 1/4 male pump connections must be counterheld and not over-torqued during hose installation.
Output data are valid at 20 °C room temperature; if the ambient rises toward the 40 °C limit, cooling capacity may drop, so plant-room ventilation and heat rejection must be sized for the actual ambient rather than the 18 kW at 0 °C figure alone.
The R-449A charge of 5.75 kg (8.0 t CO2 equivalent) triggers periodic F-gas leak checks, and any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the room volume must also be checked against the refrigerant limit per m³.
The cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion, and electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation.
The parking brakes at the casters must be activated and/or the leveling feet unscrewed before the unit is put into operation, so that the 533 kg unit cannot move and cause crushing injuries during running.
Selection & Integration Q&A
Pick the 180T when the process needs the 18 kW class at 0 °C and can accept its fixed-speed D3 pump and larger footprint. The 110T/110T-H are 74 dB(A) variants and the 110Tw/110Tw-H are 65 dB(A) variants; choose those when noise or capacity closer to the 110 class matters more than the 180T's higher cooling output.
A 400 V 3~ 50 Hz supply with 23 A maximum current and a mating plug, since the unit ships with cable but no plug. The loop must be externally closed with at least 14 l fill and 39 l expansion volume, and hoses must match the G1 1/4 male pump connections, counterheld and not over-torqued.
Indoors only, 5 to 40 °C ambient, at least 300 lx, up to 2000 m altitude, and not inside an ATEX zone. Allow 50 to 200 cm wall clearance per side for maintenance, activate leveling feet and parking brakes before start-up, and expect capacity to fall as room temperature rises above the 20 °C rating point.
No plug is included for the 400 V three-phase connection. Refrigerant circuit work on the 5.75 kg R-449A charge must be done by approved refrigeration contractors, and the 8.0 t CO2 equivalent triggers periodic F-gas leak checks. Cooling water must be shut off even overnight, and the room volume must be checked against the refrigerant limit per m³.