Peter Huber Kältemaschinenbau Unichiller 210T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 210T

Peter Huber Kältemaschinenbau Unichiller 210T — Recirculating chillers.

The Unichiller 210T is an air-cooled recirculating chiller with a 15 kW cooling capacity at 15 °C and a -20 to 40 °C working range, positioned as the larger-capacity variant in the Unichiller series. Its non-variable D3 pressure pump delivers up to 210 l/min at zero head, making it suited to closed-loop process cooling where high flow and moderate pressure are required.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 210T Current D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 15 °C)
at 0 °C: 21 kW
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The Unichiller 210T is a free-standing, air-cooled recirculating chiller using R-449A refrigerant (GWP 1397) and a non-variable D3 pressure pump. Within the Unichiller series, it is the higher-capacity sibling to the 110T variants; the 110T models are distinguished by lower noise levels (74 dB(A) for 110T/110T-H, 65 dB(A) for 110Tw/110Tw-H), whereas the 210T is specified for greater cooling duty. The unit is intended exclusively for externally closed applications and is not explosion-protected, so it must not be installed in an ATEX zone.

Performance and load behavior

Cooling capacity is 21 kW at 0 °C and 15 kW at 15 °C, dropping to 7.5 kW at -20 °C; low-temperature duty therefore requires either a larger unit or reduced load. The pump curve shows maximum delivery of 210 l/min at zero head falling to 31 l/min at 4.5 bar, so the system pressure drop must be checked against this curve to ensure adequate flow. Ambient temperature must remain between 5 and 40 °C, and capacity may fall if ambient rises.

Installation, control and operation

The Pilot ONE controller provides Ethernet, USB (Host and Device) and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto. Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles. The unit requires a 400 V three-phase 50 Hz supply; three-phase devices below 63 A are delivered with cable but without a plug. The pump connection is G1 1/4 male, and minimum filling capacity is 14 l with 39 l expansion volume. IP20 protection and EMC Class A Group 1 mean the unit must be installed indoors in a dry location and may cause radio interference in residential areas.

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for maintenance access

Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance and ensure adequate air flow for heat rejection. The unit must be installed indoors at an illuminance of at least 300 lx and at altitudes up to 2000 m.

Operation Manual, Section: Installation
Electrical
Verify site power quality within ±5% voltage and ±2% frequency

The unit requires a 400 V three-phase 50 Hz supply. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%; combinations such as -5% voltage with +2% frequency are not allowed. Three-phase devices below 63 A are delivered with cable but without a plug, so the site plug must be provided.

Datasheet, Electrical Specifications; Operation Manual, Electrical Connection
Safety
Configure Process Safety mode for exothermic reactions

In Process Safety mode, the controller releases maximum cooling capacity when the overtemperature trigger value is reached, instead of switching off all poles. This is critical for exothermic processes where loss of cooling could cause runaway temperatures. The power-failure response can be set to OFF/Standby, ON, or Power Failure Auto via the Pilot ONE.

Operation Manual, Section: Safety and Operation Modes
Operation
Activate leveling feet and parking brakes before start-up

Before putting the unit into operation, the parking brakes must be activated at the casters (if any) and/or the leveling feet must be unscrewed/activated to prevent movement and crushing injuries. Electrical lines directly below the unit must be protected against liquid ingress from condensation.

Operation Manual, Section: Commissioning

Selection & Integration Q&A

When should I choose the Unichiller 210T over the 110T variants?

Choose the 210T when higher cooling capacity is needed: 21 kW at 0 °C and 15 kW at 15 °C, versus the 110T series which is positioned at lower capacity. The 110T variants offer lower noise levels (65–74 dB(A)), so if acoustic limits are tight and capacity demand is lower, a 110T model may be preferable.

What are the requirements for connecting the 210T to my process loop?

The pump connection is G1 1/4 male, so mating hoses and fittings must match this thread. The external loop must be closed and its pressure drop checked against the pump curve (210 l/min at 0 bar to 31 l/min at 4.5 bar). Minimum filling capacity is 14 l and expansion volume is 39 l; ensure the loop volume and fluid selection are compatible.

What installation environment and duty-cycle limits apply to the 210T?

Install indoors only, at 5–40 °C ambient, with 50–200 cm side clearance for maintenance, at least 300 lx illuminance, and up to 2000 m altitude. IP20 requires a dry, protected location. The unit is not ATEX-rated and must not be used in hazardous zones. Cooling capacity may drop if ambient temperature rises.

What maintenance and accessories are required that are not included in the base delivery?

The base delivery includes a cable but no plug for the 400 V three-phase supply; the site must provide a suitable plug. Refrigerant circuit work must be performed by approved refrigeration contractors. Regular maintenance includes checking refrigerant charge and room size per m³, and shutting off cooling water (if applicable) during downtimes. No specific maintenance interval is stated in the provided documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 210T Datasheet
Datasheet ·17,7 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF