Peter Huber Kältemaschinenbau Unichiller 210Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 210Tw

Peter Huber Kältemaschinenbau Unichiller 210Tw — Recirculating chillers.

The Unichiller 210Tw is a water-cooled recirculating chiller with a fixed-speed D3 pressure pump, rated for -20 to 40 °C and 400 V 3~ 50 Hz. It is the larger-capacity member of the Unichiller T series, distinguished from the 110T/110Tw siblings by its 22 l expansion volume and 15 l minimum fill. It serves externally closed process loops requiring stable temperature control in industrial environments.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 210Tw Current D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 22 l
Minimum fill volume 15 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior and process limits

Installation, control and operation

Integration & Operating Notes

Process Limits
Cooling water inlet must stay between 5 and 20 °C

Operating above 20 °C reduces capacity and raises flow demand; operating below the dew point requires insulation of the internal cooling-water pipes to prevent condensation and corrosion. Verify the site cooling-water temperature against this band before commissioning.

Unichiller 210Tw Datasheet, page 2
Process Limits
Cooling water differential pressure: min 1 bar, max 6 bar

Insufficient differential pressure prevents proper cooling; pressure above 6 bar may damage the cooling circuit. The site supply must be checked against both limits, and the G3/4 male connection must be matched.

Unichiller 210Tw Datasheet, page 1
Electrical
Voltage and frequency tolerances are coupled, not independent

The ±5% voltage tolerance applies only with a simultaneous ±2% frequency tolerance, and certain combinations (e.g. -5% voltage with +2% frequency) are not permitted. Site power quality must be verified before connection.

Unichiller 210Tw Datasheet, page 2
Electrical
Three-phase unit supplied with cable but without plug

Because current consumption is below 63 A, the unit ships with a cable but no plug; a suitable plug must be provided on site. Electrical lines directly below the water-cooled unit must be protected against liquid ingress from condensation.

Unichiller 210Tw Datasheet, page 2; Operation Manual, page 28
Mounting
Indoor installation only, outside ATEX zones, with side clearance

The unit is not explosion-protected and must not be installed or started in an ATEX zone. It requires indoor use at ≥300 lx illuminance, up to 2000 m altitude, and 50–200 cm wall clearance per side for maintenance. Leveling feet must be activated and parking brakes applied before start-up.

Operation Manual, pages 13, 25, 31
Maintenance
Refrigerant circuit work restricted to approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A (GHS H280, pressurized gas), so handling and ventilation precautions apply, and refrigerant charge versus room size must be checked at installation.

Operation Manual, pages 15, 17
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion during idle periods. Pump connections must be counterheld and maximum tightening torques must not be exceeded during hose installation.

Operation Manual, page 28

Selection & Integration Q&A

When should I choose the 210Tw rather than a 110T or 110Tw sibling?

Choose the 210Tw when the external loop needs the larger 22 l expansion volume and 15 l minimum fill, and when water cooling is available. The 110T is air-cooled; the 110Tw is the smaller water-cooled variant. The 'P' models are for high pressure-drop loops, which this is not.

What site services and mating connections must be ready before commissioning?

Provide 400 V 3~ 50 Hz with ±5%/±2% coupled tolerance and a suitable plug (cable supplied, plug not). Cooling water: G3/4 male connection, 5–20 °C inlet, 1–6 bar differential pressure. Process loop: G1 1/4 AG male pump connection, externally closed, ≥15 l fill.

What mounting and environment limits apply from the manual?

Install indoors only, not in an ATEX zone, at ≥300 lx and up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance. Ambient 5–40 °C, IP20 (dry environment). Activate leveling feet and parking brakes before start-up; protect electrical lines below the unit from condensate.

What maintenance and consumables are not included in base delivery?

The unit ships with cable but no plug; hoses, fittings and thermal fluid for the external loop are not included. Refrigerant circuit service must be by approved contractors (R-449A). Cooling water must be shut off for even overnight downtime; check refrigerant charge versus room size at installation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 210Tw Datasheet
Datasheet ·172,8 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF