Peter Huber Kältemaschinenbau Unichiller GL 1000w
Peter Huber Kältemaschinenbau Unichiller GL 1000w — Recirculating chillers.
The Unichiller GL 1000w is a water-cooled recirculating chiller rated at 100 kW cooling at 20 °C, operating from -20 to 40 °C with a fixed-speed pressure pump (320 l/min max, 110 l/min at 4.0 bar). It is the 460 V/60 Hz three-phase variant in the Unichiller series, intended for externally closed process loops requiring high cooling capacity.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller GL 1000w Current | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 50 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1 1/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The GL 1000w is a water-cooled (not air-cooled) recirculating chiller in the Unichiller series. Unlike the air-cooled Unichiller 110T/110Tw siblings, it uses a cooling-water circuit with G1 1/4 male connections and requires a facility cooling-water supply of 5–20 °C at minimum 1 bar differential pressure (maximum 6 bar). The pump is a fixed-speed pressure pump (not speed-variable) delivering up to 320 l/min, with 110 l/min available at 4.0 bar. The unit is controlled by the Pilot ONE controller and provides Ethernet, USB (host and device) and RS232 interfaces plus a Pt100 external sensor input. The 50 l expansion volume supports a substantial external loop.
Behavior and process limits
The unit is rated for 100 kW cooling at 20 °C and operates over a -20 to 40 °C temperature range. It is intended exclusively for externally closed applications; open external circuits are not permitted. Overtemperature protection according to DIN 12876 is adjustable, and the controller offers a Process Safety mode that releases maximum cooling capacity when the OT trigger value is reached rather than switching off all poles — relevant for exothermic processes. The power-failure response is configurable (OFF/Standby, ON, or Power Failure Auto) via the Pilot ONE.
Installation and operation
Electrical supply is 460 V three-phase 60 Hz; three-phase devices under 63 A are supplied with cable but without a plug. Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%, and the combination of -5% voltage with +2% frequency is not allowed. Leakage current exceeds 3.5 mA, so protective earthing and RCD design must account for this; external branch circuit protection per UL 489 is required. The unit must be installed indoors at ≥300 lx and up to 2000 m altitude, outside any ATEX zone, with 50–200 cm wall clearance per side for maintenance. Leveling feet or parking brakes must be secured before startup. Cooling-water pipes must be insulated if water temperature falls below the condensation point, and electrical lines directly below the unit must be protected against liquid ingress. The cooling-water supply must be shut off even for overnight downtimes.
Integration & Operating Notes
The unit is designed exclusively for externally closed applications. Connecting an open external circuit can cause overflow, contamination, or unsafe operation, and voids the intended use. Verify the process loop is sealed and pressure-rated before commissioning.
The water-cooled refrigeration circuit requires cooling-water inlet between 5 °C and 20 °C with at least 1 bar differential pressure (maximum 6 bar). Facility supply outside this envelope will degrade or prevent rated cooling. If water temperature falls below the condensation point, internal cooling-water pipes must be insulated.
Leakage current exceeds 3.5 mA, so the protective earth conductor and any residual current device must be sized for high leakage. External branch circuit protection per UL 489 is required. The unit is supplied with cable but without a plug for three-phase connection under 63 A.
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and the specific combination of -5% voltage with +2% frequency is explicitly not allowed. Verify supply quality at the installation point before connection to avoid operating outside the allowed envelope.
Free-standing installation requires 50 to 200 cm wall clearance on either side for maintenance access. Leveling feet must be unscrewed/activated and parking brakes applied before switching on to prevent movement and crushing injury. Indoor use only, at ≥300 lx and up to 2000 m altitude, outside any ATEX zone.
The refrigerant is R-744 (A1, H280, GWP 1, UN 2857). Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Check refrigerant charge against room size at installation to avoid exceeding the limit per m³ of ambient air.
The Pilot ONE allows power-failure response OFF/Standby, ON, or Power Failure Auto, and Process Safety mode releases maximum cooling at the OT trigger instead of switching off. For exothermic processes, select Process Safety and set the adjustable DIN 12876 overtemperature trigger for the application.
The cooling-water supply must be shut off during shorter downtimes such as overnight to prevent water damage and corrosion. Electrical lines directly below the water-cooled unit must be protected against liquid ingress from condensation.
Selection & Integration Q&A
Choose the GL 1000w when you need 100 kW cooling at 20 °C and have a facility cooling-water supply of 5–20 °C at ≥1 bar Δp; it is water-cooled and avoids the 65–74 dB(A) fan noise of the 110T/110Tw air-cooled siblings. Pick a sibling when no cooling water is available or when a smaller air-cooled unit suffices.
The fixed-speed pressure pump delivers up to 320 l/min (110 l/min at 4.0 bar) through G1 1/4 male connections; size the external loop pressure drop against this curve. Mating hoses and fittings must be G1 1/4, and the maximum tightening torque must not be exceeded with connections counterheld.
Install indoors only, outside ATEX zones, at ≥300 lx and up to 2000 m altitude, with 5–40 °C ambient and 50–200 cm clearance per side. Secure leveling feet/parking brakes before startup. Shut off cooling water even overnight, and insulate cooling-water pipes if below the condensation point.
Three-phase units under 63 A ship with cable but without a plug; the installer must provide a plug or hardwired connection plus UL 489 branch protection. Refrigerant-circuit service requires approved refrigeration contractors. No accessories or consumables are listed in the verified facts beyond the cable.