Peter Huber Kältemaschinenbau Unichiller 250T-H
Peter Huber Kältemaschinenbau Unichiller 250T-H — Recirculating chillers.
The Unichiller 250T-H is a 400 V three-phase, air-cooled recirculating chiller with a Pilot ONE controller and a fixed-speed D3 pump (210 l/min, 4.7 bar max). It delivers 18 kW at 0 °C and 6 kW at -20 °C within a -20…100 °C range, distinguishing it from lower-capacity 110T siblings. It serves externally closed industrial cooling loops requiring 14–39 l fill and G1 1/4 male connections.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 250T-H Current | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 25 °C) at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The 250T-H is the high-capacity member of the Unichiller T series; siblings 110T/110Tw are lower-capacity variants (noise 74 dB(A) and 65 dB(A) respectively).
- Cooling circuit uses R-449A (A1, H280) refrigerant; unit is EMC Class A Group 1 and IP20.
- Pump is type D3, speed not adjustable, with G1 1/4 AG male connections; expansion volume 39 l, minimum fill 14 l.
- Heating capacity 2 kW supplements the cooling function.
Behavior under load and media
- Cooling capacity is rated at 20 °C ambient: 18 kW at 0 °C, 15 kW at 25 °C, 11 kW at -10 °C, 6 kW at -20 °C; capacity drops as ambient rises.
- Temperature range -20…100 °C; ambient limit 5…40 °C.
- Intended for externally closed applications only; not for open-loop or vented setups.
- Pump delivers max 210 l/min at max 4.7 bar, with flow decreasing as pressure rises.
Installation, control and operation
- Requires 400 V 3~ 50 Hz supply; three-phase units below 63 A are supplied with cable but without plug.
- Pilot ONE controller provides Ethernet, USB (Host and Device), RS232, and Pt100 external sensor connection.
- Power-failure response configurable as OFF/Standby, ON, or Power Failure Auto.
- Process Safety mode releases maximum cooling when OT trigger is reached.
- Must be installed indoors, at ≥300 lx, up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance.
Integration & Operating Notes
The installer must provide a suitable mating plug for the supplied cable. Plan for a 400 V 3~ 50 Hz supply with appropriate overcurrent protection; the unit does not include a plug for direct connection.
Free-standing models require this clearance on either side to allow service access and adequate air flow for heat rejection. Insufficient clearance will reduce cooling capacity and may cause overheating.
The unit is not explosion-protected and must not be installed in an ATEX zone. It requires a dry, protected environment (IP20) and sufficient lighting for safe operation and maintenance.
The hydraulic circuit must be closed and have a minimum volume of 14 l to ensure stable pump operation and sufficient thermal mass. The expansion volume is 39 l; do not exceed the maximum fill or the expansion tank may overflow.
Rated capacities are valid at 20 °C room temperature. If the installation site ambient exceeds this, available cooling at each temperature setpoint will be lower; size the unit with margin or provide additional ventilation.
The Pilot ONE allows OFF/Standby, ON, or Power Failure Auto. For unattended processes, Power Failure Auto restarts automatically; for safety-critical exothermic reactions, choose OFF/Standby to prevent uncontrolled restart.
Instead of switching off all poles, this mode activates full cooling when the overtemperature trigger is reached. Use only when the process requires rapid heat removal to prevent runaway; otherwise standard OT shutdown is safer.
Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A is classified A1 with GHS hazard H280 (pressurized gas); observe room size and charge limits.
Selection & Integration Q&A
Choose the 250T-H when you need higher cooling capacity (18 kW at 0 °C vs lower for 110T) and a -20…100 °C range. The 110Tw offers lower noise (65 dB(A)) but less capacity; select 250T-H for high heat loads, 110Tw for noise-sensitive areas with lower demand.
Use G1 1/4 male connections with hoses rated for the max pressure (4.7 bar) and temperature. Ensure the loop is externally closed with at least 14 l fill volume and a maximum of 39 l expansion. Provide a 400 V 3~ 50 Hz supply; the unit ships with cable but no plug.
Install indoors only, at 5–40 °C ambient, ≥300 lx illuminance, max 2000 m altitude, and not in an ATEX zone. Maintain 50–200 cm wall clearance per side. The unit is IP20, so keep it dry and dust-free. Cooling capacity is rated at 20 °C ambient; higher ambient reduces capacity.