Peter Huber Kältemaschinenbau Unichiller 260Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 260Tw

Peter Huber Kältemaschinenbau Unichiller 260Tw — Recirculating chillers.

The Unichiller 260Tw is a water-cooled recirculating chiller with a 210 l/min pump and a -20 to 40 °C working range, distinguished from the air-cooled 110T siblings by its water-cooled condenser and higher-capacity pump. It serves externally closed process loops requiring up to 4.7 bar delivery pressure.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 260Tw Current D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 22 l
Minimum fill volume 15 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 375 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-449A (A1, H280) (1st stage)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Hydraulic and thermal behavior

Installation, control and operation

Integration & Operating Notes

Cooling & Media
Cooling water must stay within 5–20 °C and 1–6 bar

Below 5 °C or above 20 °C inlet the rated cooling capacity is not valid; below the condensation point the cooling water pipes must be insulated to prevent condensate. Differential pressure below 1 bar starves the condenser, above 6 bar risks connection damage.

Unichiller 260Tw Datasheet, page 2
Electrical
Supply tolerances must not have opposite signs

Voltage tolerance ±5% and frequency tolerance ±2% apply simultaneously; a -5% voltage with +2% frequency is explicitly not allowed. Plan the 3x32 A fuse and 27.5 A max current, and provide a suitable plug since the cable is supplied without one.

Unichiller 260Tw Datasheet, page 2
Mounting
Keep 50–200 cm clearance per side for maintenance

Free-standing installation requires this wall clearance on either side. Indoors only, illuminance at least 300 lx, altitude up to 2000 m, ambient 5–40 °C. Check refrigerant charge against room volume to avoid exceeding the limit per m³.

Unichiller Operation Manual, page 25
Mounting
Protect cables below the unit from condensate

Because the condenser is water-cooled, electrical lines routed directly below the unit must be protected against liquid ingress from condensation. Also secure the unit: activate parking brakes and/or unscrew leveling feet before switching on.

Unichiller Operation Manual, pages 28 and 31
Process Limits
Externally closed circuits only; no ATEX zones

The unit is designed for externally closed applications and is not explosion-protected, so it must not be installed or started inside an ATEX zone. For high-pressure-drop loops, a 'P' model is the correct choice instead of this unit.

Unichiller Operation Manual, pages 13 and 34
Control & I/O
Configure power-failure response before unattended runs

The Pilot ONE allows OFF/Standby, ON or Power Failure Auto after mains loss. For exothermic processes, Process Safety mode releases maximum cooling at the OT trigger rather than switching off all poles, preventing runaway temperatures.

Unichiller Operation Manual, pages 18–19
Maintenance
Refrigerant work only by approved contractors

Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Shut off the cooling water supply even for short downtimes such as overnight to prevent water damage and corrosion.

Unichiller Operation Manual, pages 17 and 28

Selection & Integration Q&A

When should I choose the 260Tw over the 110T or 110Tw siblings?

Pick the 260Tw when you need the higher 210 l/min pump and water-cooled condenser for a large externally closed loop. The 110T is air-cooled (74 dB(A)); the 110Tw is water-cooled at 65 dB(A) but with lower pump capacity. Choose a 'P' model instead for high-pressure-drop circuits.

What must the external hydraulic circuit and power supply provide?

Pump connections are G1 1/4 male; size the loop so pressure drop matches the pump curve (210 l/min max, 4.7 bar max, 31 l/min at 4.5 bar). Cooling water: G3/4 male, 5–20 °C, 1–6 bar differential. Electrical: 400 V 3~ 50 Hz, 27.5 A max, 3x32 A fuse, plug not included.

Where can the unit be installed and what clearances apply?

Indoors only, 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, IP20. Allow 50–200 cm wall clearance per side for maintenance. Not permitted in ATEX zones. Protect cables below the unit from condensate and check refrigerant charge against room volume.

What maintenance and accessories are required beyond the base delivery?

The unit ships with a cable but no plug, so the customer supplies a suitable 3-phase plug. Refrigerant circuit service is restricted to approved contractors. Shut off cooling water during downtimes. Insulate cooling water pipes if inlet temperature falls below the condensation point.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 260Tw Datasheet
Datasheet ·172,9 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF