Peter Huber Kältemaschinenbau Unichiller 300T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 300T

Peter Huber Kältemaschinenbau Unichiller 300T — Recirculating chillers.

The Unichiller 300T is an air-cooled recirculating chiller with a fixed-speed D3 pressure pump and G1 1/4 male connections, rated for -20 to 40 °C. Its cooling capacity falls from 30 kW at 15 °C to 6 kW at -20 °C, so sizing must follow the actual process temperature. It serves externally closed industrial cooling loops on a 400 V three-phase supply.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 300T Current D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The 300T is the largest of the Unichiller T-series models listed here; siblings 110T, 110T-H, 110Tw and 110Tw-H are smaller-capacity units (their published noise figures are 74 dB(A) for 110T/110T-H and 65 dB(A) for the Tw variants). The 300T uses a Pilot ONE controller, a D3 pressure pump with non-variable speed, and G1 1/4 male pump connections. The refrigerant is R-449A (A1, H280) with GWP 1397. The unit is rated IP20 and EMC Class A Group 1, i.e. industrial-environment equipment.

Thermal behavior

Installation and control

Commissioning requires a 400 V 3~ 50 Hz feed; three-phase devices below 63 A are delivered with cable but without a plug. Supply tolerance is ±5% voltage with simultaneous ±2% frequency, and some combinations are not permitted. The unit is air-cooled and needs the manufacturer's space requirements respected; a wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. Leveling feet must be activated and parking brakes applied before start-up. The Pilot ONE provides Ethernet, USB (host and device) and RS232 interfaces, a Pt100 external sensor connection, and a configurable power-failure response (OFF/Standby, ON, Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.

Integration & Operating Notes

Process Limits
Cooling capacity must be sized at the actual process temperature

Capacity falls steeply as the setpoint drops (30 kW at 15 °C versus 6 kW at -20 °C), so a loop sized on the warm-end figure will be undersized for low-temperature duty. The published data are valid at 20 °C room temperature and may derate in warmer plant rooms.

Unichiller 300T Datasheet, Specifications
Electrical
Three-phase feed is supplied with cable but no plug

The 400 V 3~ 50 Hz unit below 63 A arrives with a cable only, so the customer must provide the final connection. Voltage tolerance is ±5% only with simultaneous ±2% frequency tolerance, and some combinations are not allowed, so supply quality should be verified before commissioning.

Unichiller 300T Datasheet, Installation notes
Mounting
Air-cooled unit needs clearance and a dry indoor site

The IP20 enclosure must be installed indoors, protected from water and dust, at 5 to 40 °C ambient and at least 300 lx illuminance. A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models, and the manufacturer's space requirements must be respected to avoid reduced cooling performance.

Unichiller Operation Manual, Installation
Process Limits
Externally closed circuits only; ATEX zones excluded

The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Refrigerant charge and room size must be checked at installation to stay within the refrigerant limit per m³ of ambient air.

Unichiller Operation Manual, Function Description and Installation
Maintenance
Refrigerant circuit work is restricted to approved contractors

Any work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A with GWP 1397, so handling and greenhouse-gas reporting obligations apply; the rating plate and datasheet give the charge.

Unichiller Operation Manual, Maintenance

Selection & Integration Q&A

When should I choose the Unichiller 300T instead of the 110T or 110Tw siblings?

Pick the 300T when the required cooling capacity at the actual process temperature exceeds what the 110T family delivers; the 300T provides 30 kW at 15 °C down to 6 kW at -20 °C. The 110Tw variants are the quieter option (65 dB(A) versus 74 dB(A) for 110T/110T-H), so choose a Tw sibling where noise is the deciding constraint.

What must the external hydraulic circuit and pump-side connections provide?

The pump connection is G1 1/4 male, so hoses and fittings must match that thread and be counterheld at the maximum tightening torque. The D3 pump is not speed-variable: it delivers up to 210 l/min and 4.7 bar, with 202 l/min at 1.1 bar, so the external pressure drop must be checked against that curve. Loop volume must be at least 14 l with 39 l expansion volume.

What is not included in base delivery and what service obligations follow?

Three-phase units below 63 A ship with a cable but without a plug, so the final connection is customer-supplied. Refrigerant-circuit work must be done by approved refrigeration contractors; R-449A has GWP 1397, so charge and room size must be checked and reporting obligations apply. Shut off cooling water even overnight on water-cooled installations.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller 300T Datasheet
Datasheet ·17,7 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF