The Unichiller 300T-H is a free-standing, water-cooled recirculating chiller with a Pilot ONE controller, rated -20 to 100 °C and 6–18 kW cooling capacity across that window. It is the high-capacity modification in the Unichiller T series, distinguished by its 460 V three-phase supply and G1 1/4 pump connection. It serves externally closed process loops requiring stable temperature control from sub-zero to near-boiling setpoints.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 300T-H Current | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 30 °C) at 0 °C: 18 kW · at -10 °C: 11 kW · at -20 °C: 6 kW |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The 300T-H is a free-standing recirculating chiller with overall dimensions of 905 × 2172 × 1900 mm (W × D × H). It uses refrigerant R-449A (A1, H280) and is rated IP20. Within the Unichiller T series, the 300T-H is the larger-capacity, three-phase variant; the sibling 110T/110Tw models are smaller units with different noise profiles. The 300T-H carries a fixed-speed D3 pressure pump with a G1 1/4 male connection and no speed adjustment. The controller is the Pilot ONE, with Ethernet, USB (host and device) and RS232 interfaces and a Pt100 external sensor input.
Thermal behavior
Cooling capacity is strongly setpoint-dependent: 18 kW at 0 °C, 11 kW at -10 °C and 6 kW at -20 °C. Sizing must therefore use the capacity at the actual process setpoint, not the nominal figure. A 2 kW heating capacity is available for warm-side control. The published output data are valid at 20 °C room temperature; higher ambient reduces achievable cooling capacity. The unit is intended for externally closed applications only.
Hydraulics and control
The loop requires a minimum fill of 14 l, and the expansion volume is 39 l, which sets the minimum external circuit volume and expansion allowance. The pump connection is G1 1/4 male; mating hoses and couplings must match this thread and must be counterheld during tightening within the manual's torque limits. The Pilot ONE provides the power-failure response setting (OFF/Standby, ON, or Power Failure Auto) and the Process Safety mode, which releases maximum cooling capacity when the overtemperature trigger is reached rather than switching off all poles.
Integration & Operating Notes
The unit requires a 460 V 3~ 60 Hz supply. Voltage tolerance is ±5% and frequency ±2%, but the two must not combine in the unfavorable direction. External branch circuit protection per UL 489 is mandatory and must be provided by the installer. Three-phase devices under 63 A are delivered with cable but without a plug, so a suitable plug must be sourced on site.
Free-standing models require a wall clearance of 50 to 200 cm on either side for maintenance access. The unit may only be used indoors, at an illuminance of at least 300 lx and up to 2000 m altitude. Ambient temperature must remain between 5 and 40 °C. Leveling feet must be activated and parking brakes applied before startup.
The unit is designed for externally closed applications. Cooling capacity falls from 18 kW at 0 °C to 6 kW at -20 °C, so the loop heat load must be checked against the capacity at the actual operating setpoint. Minimum fill is 14 l and expansion volume is 39 l; the external circuit must accommodate both. Output data are valid at 20 °C room temperature and may drop at higher ambient.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles. The chosen logic must match the process risk assessment before commissioning.
Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. Refrigerant R-449A is classified A1 with GHS H280; charge and room size must be checked at installation to avoid exceeding the refrigerant limit per m³ of ambient air. Cooling water supply must be shut off even for short downtimes such as overnight.
The unit is not explosion-protected and must not be installed or started up inside an ATEX zone. Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. The unit is EMC Class A Group 1 to EN55011, which may require attention in residential-like environments.
Selection & Integration Q&A
Choose the 300T-H when the process needs up to 18 kW at 0 °C and a -20 to 100 °C window on a 460 V three-phase supply. The 110T/110Tw siblings are smaller-capacity units; select them only when their lower capacity covers the load and their supply matches the site.
The loop must be externally closed with at least 14 l fill and allowance for 39 l expansion, connected via G1 1/4 male threads with counterheld fittings. Power must be 460 V 3~ 60 Hz within ±5% voltage and ±2% frequency, with a UL 489 breaker and a site-supplied plug.
Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm side clearance for maintenance. Activate leveling feet and parking brakes before startup. Do not place the unit in an ATEX zone; protect cables below it from condensation.
The unit ships with cable but without a plug for three-phase supply under 63 A, so a plug and UL 489 breaker are site-supplied. Refrigerant circuit service must be performed by approved contractors. Cooling water supply must be shut off during downtimes; no external sensor or mating hoses are stated as included.