Peter Huber Kältemaschinenbau Unichiller 200T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 200T

Peter Huber Kältemaschinenbau Unichiller 200T — Recirculating chillers.

The Unichiller 200T is a recirculating chiller with a 10 kW cooling capacity at 0 °C and a -20…40 °C working range, built for externally closed industrial process circuits. Its D3 pump delivers 202 l/min at 1.1 bar, making it the higher-capacity modification in the Unichiller series. It serves as a central cooling source for closed-loop heat exchangers and process equipment.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller 200T Current D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 250w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 39 l
Minimum fill volume 14 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type D3
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 20 °C)
at 0 °C: 10 kW · at -10 °C: 5 kW · at -20 °C: 3 kW
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Electrical
External UL 489 branch protection and site plug required

The installer must provide a branch circuit protection device per UL 489; the unit ships with a cable but no plug for three-phase currents below 63 A, so a suitable plug must be sourced. Voltage and frequency tolerances must be met simultaneously—combinations such as -5% voltage with +2% frequency are not permitted.

Unichiller 200T Technical Datasheet, page 2
Mounting
Indoor IP20 location with 50–200 cm side clearance

The IP20 enclosure requires a dry indoor site protected from water and dust; a wall clearance of 50 to 200 cm per side is needed for maintenance on free-standing models, and illuminance must be at least 300 lx. The unit must not be installed in an ATEX zone.

Unichiller Operation Manual, pages 13 and 25
Process Limits
Externally closed circuit only; match pump curve to pressure drop

The chiller is designed only for externally closed applications, so open-loop or vented process circuits are excluded. The fixed-speed D3 pump delivers 202 l/min at 1.1 bar but only 77 l/min at 4.0 bar; the external circuit resistance must be checked against this curve to avoid insufficient flow.

Unichiller 200T Technical Datasheet, page 1; Operation Manual, page 34
Control & I/O
Configure power-failure response and Process Safety mode

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto; for exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles. These settings determine restart behavior and safe shutdown.

Unichiller Operation Manual, pages 18–19
Maintenance
Refrigerant work only by approved contractors; check tank level

Work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning contractors. The atmospheric open expansion tank has a cover and requires routine level checks and venting; refrigerant charge and room size must be verified at installation to avoid exceeding the limit per m³ of ambient air.

Unichiller Operation Manual, pages 15 and 17; Datasheet, page 1
Cooling & Media
Cooling capacity derates with rising ambient temperature

Catalogue cooling capacities are valid at a room temperature of 20 °C; if the ambient temperature rises, the cooling capacity may drop, so the unit should be sized for the actual room temperature rather than the 20 °C values. Ambient temperature must stay between 5 °C and 40 °C.

Unichiller 200T Technical Datasheet, pages 1–2

Selection & Integration Q&A

When should I choose the Unichiller 200T over the 110T or 110Tw siblings?

Choose the 200T when you need 10 kW at 0 °C and a -20…40 °C range with a fixed D3 pump; the 110T variants are smaller and differ in noise level (74 dB(A) for 110T/110T-H, 65 dB(A) for 110Tw/110Tw-H). Select a sibling if your load is below the 200T capacity or if lower noise is required.

What electrical supply and protection must be provided for the 200T?

The unit requires 460 V 3~ 60 Hz and an external branch circuit protection device per UL 489, which the installer must provide. Three-phase units under 63 A ship with a cable but without a plug, so a suitable plug must be sourced on site. Voltage and frequency tolerances must be met simultaneously.

What are the mounting and environment limits for the 200T?

Install indoors only, in a dry location with at least 300 lx illuminance and ambient temperature between 5 °C and 40 °C. Provide 50–200 cm wall clearance per side for maintenance, activate leveling feet and parking brakes before startup, and do not install in an ATEX zone.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes a cable but no plug for three-phase units under 63 A. Refrigerant circuit work must be done by approved contractors; the atmospheric expansion tank requires level checks and venting. No specific maintenance interval is stated in the provided documents.