Peter Huber Kältemaschinenbau Unichiller 200T
Peter Huber Kältemaschinenbau Unichiller 200T — Recirculating chillers.
The Unichiller 200T is a recirculating chiller with a 10 kW cooling capacity at 0 °C and a -20…40 °C working range, built for externally closed industrial process circuits. Its D3 pump delivers 202 l/min at 1.1 bar, making it the higher-capacity modification in the Unichiller series. It serves as a central cooling source for closed-loop heat exchangers and process equipment.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 200T Current | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 20 °C) at 0 °C: 10 kW · at -10 °C: 5 kW · at -20 °C: 3 kW |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The Unichiller 200T is a free-standing, air-cooled recirculating chiller with an atmospheric open expansion tank (39 l expansion volume, 14 l minimum fill).
- Within the Unichiller series, it is the larger-capacity sibling of the 110T variants; the 110T models are rated at 74 dB(A) or 65 dB(A) depending on variant, while the 200T is distinguished by its 10 kW cooling capacity at 0 °C.
- The unit is rated IP20 and must be installed indoors in a dry, protected location.
Behavior under load and media
- Cooling capacity is 10 kW at 0 °C, 15 kW at 20 °C, 5 kW at -10 °C and 3 kW at -20 °C; capacity drops as ambient temperature rises above the 20 °C reference.
- The D3 pressure pump is not speed-adjustable; its delivery is 202 l/min at 1.1 bar and 77 l/min at 4.0 bar, so the external circuit pressure drop must be matched to this fixed curve.
- The unit is intended only for externally closed applications; open-loop or vented circuits are outside its design intent.
Installation, control and operation
- The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection.
- Power supply is 460 V 3~ 60 Hz; an external branch circuit protection device per UL 489 must be provided by the installer, and three-phase units under 63 A ship with a cable but without a plug.
- The power-failure response is configurable (OFF/Standby, ON, or Power Failure Auto), and Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.
- Leveling feet must be activated and parking brakes applied before startup; wall clearance of 50–200 cm per side is required for maintenance.
Integration & Operating Notes
The installer must provide a branch circuit protection device per UL 489; the unit ships with a cable but no plug for three-phase currents below 63 A, so a suitable plug must be sourced. Voltage and frequency tolerances must be met simultaneously—combinations such as -5% voltage with +2% frequency are not permitted.
The IP20 enclosure requires a dry indoor site protected from water and dust; a wall clearance of 50 to 200 cm per side is needed for maintenance on free-standing models, and illuminance must be at least 300 lx. The unit must not be installed in an ATEX zone.
The chiller is designed only for externally closed applications, so open-loop or vented process circuits are excluded. The fixed-speed D3 pump delivers 202 l/min at 1.1 bar but only 77 l/min at 4.0 bar; the external circuit resistance must be checked against this curve to avoid insufficient flow.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto; for exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles. These settings determine restart behavior and safe shutdown.
Work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning contractors. The atmospheric open expansion tank has a cover and requires routine level checks and venting; refrigerant charge and room size must be verified at installation to avoid exceeding the limit per m³ of ambient air.
Catalogue cooling capacities are valid at a room temperature of 20 °C; if the ambient temperature rises, the cooling capacity may drop, so the unit should be sized for the actual room temperature rather than the 20 °C values. Ambient temperature must stay between 5 °C and 40 °C.
Selection & Integration Q&A
Choose the 200T when you need 10 kW at 0 °C and a -20…40 °C range with a fixed D3 pump; the 110T variants are smaller and differ in noise level (74 dB(A) for 110T/110T-H, 65 dB(A) for 110Tw/110Tw-H). Select a sibling if your load is below the 200T capacity or if lower noise is required.
The unit requires 460 V 3~ 60 Hz and an external branch circuit protection device per UL 489, which the installer must provide. Three-phase units under 63 A ship with a cable but without a plug, so a suitable plug must be sourced on site. Voltage and frequency tolerances must be met simultaneously.
Install indoors only, in a dry location with at least 300 lx illuminance and ambient temperature between 5 °C and 40 °C. Provide 50–200 cm wall clearance per side for maintenance, activate leveling feet and parking brakes before startup, and do not install in an ATEX zone.
The base delivery includes a cable but no plug for three-phase units under 63 A. Refrigerant circuit work must be done by approved contractors; the atmospheric expansion tank requires level checks and venting. No specific maintenance interval is stated in the provided documents.